MLY(4)       Kernel Interfaces Manual   MLY(4)

NAME
       mly -- Mylex AcceleRAID/eXtremeRAID family driver

SYNOPSIS
       device pci
       device mly
       device scbus
       device da

DESCRIPTION
       The  mly  driver provides support for Mylex AcceleRAID and eXtremeRAID-
       family PCI to  SCSI  RAID  controllers  with  version  6.00  and  later
       firmware.

       Logical devices (array drives) attached to the controller are presented
       to  the SCSI  subsystem as though they were direct-access devices on a
       virtual SCSI bus.  Physical devices which are not claimed by a  logical
       device are presented on SCSI channels which match the physical channels
       on the controller.

HARDWARE
       Controllers supported by the mly driver include:

          Mylex AcceleRAID 160
          Mylex AcceleRAID 170
          Mylex AcceleRAID 352
          Mylex eXtremeRAID 2000
          Mylex eXtremeRAID 3000

       Compatible  Mylex controllers not listed should work, but have not been
       verified.

DIAGNOSTICS
   Controller initialisation phase
       mly%d: controller initialisation started
       mly%d: initialisation complete

       The controller firmware has  started  initialisation. Normally  this
       process is performed by the controller BIOS, but the driver may need to
       do  this in cases where the BIOS has failed, or is not compatible (e.g.
       on non-x86 systems).

       mly%d: drive spinup in progress

       Drive startup is in progress; this may take several minutes.

       mly%d: mirror race recovery failed, one or more drives offline
       mly%d: mirror race recovery in progress
       mly%d: mirror race recovery on a critical drive

       These error codes are undocumented.

       mly%d: FATAL MEMORY PARITY ERROR

       Firmware detected a fatal memory error; the driver will not attempt  to
       attach to this controller.

       mly%d: unknown initialisation code %x

       An unknown error occurred during initialisation; it will be ignored.

   Driver initialisation/shutdown phase
       mly%d: can't enable busmaster feature
       mly%d: memory window not available
       mly%d: can't allocate register window
       mly%d: can't allocate interrupt
       mly%d: can't set up interrupt

       The system's PCI BIOS has not correctly configured the controller's PCI
       interface;  initialisation has failed and the driver will not attach to
       this controller.

       mly%d: can't allocate parent DMA tag
       mly%d: can't allocate buffer DMA tag
       mly%d: can't allocate command packet DMA tag
       mly%d: can't allocate scatter/gather DMA tag
       mly%d: can't allocate s/g table
       mly%d: can't allocate memory mailbox DMA tag
       mly%d: can't allocate memory mailbox

       A resource allocation error occurred  while  initialising  the  driver;
       initialisation  has  failed and the driver will not attach to this con-
       troller.

       mly%d: BTL rescan result corrupted

       The results of a scan for an attached device were  corrupted.   One  or
       more devices may not be correctly reported.

       mly%d: flushing cache...

       The controller cache is being flushed prior to detach or shutdown.

   Operational diagnostics
       mly%d: physical device %d:%d online
       mly%d: physical device %d:%d standby
       mly%d: physical device %d:%d automatic rebuild started
       mly%d: physical device %d:%d manual rebuild started
       mly%d: physical device %d:%d rebuild completed
       mly%d: physical device %d:%d rebuild cancelled
       mly%d: physical device %d:%d rebuild failed for unknown reasons
       mly%d: physical device %d:%d rebuild failed due to new physical device
       mly%d:  physical  device  %d:%d rebuild  failed  due  to logical drive
       failure
       mly%d: physical device %d:%d found
       mly%d: physical device %d:%d gone
       mly%d: physical device %d:%d unconfigured
       mly%d: physical device %d:%d expand capacity started
       mly%d: physical device %d:%d expand capacity completed
       mly%d: physical device %d:%d expand capacity failed
       mly%d: physical device %d:%d parity error
       mly%d: physical device %d:%d soft error
       mly%d: physical device %d:%d miscellaneous error
       mly%d: physical device %d:%d reset
       mly%d: physical device %d:%d active spare found
       mly%d: physical device %d:%d warm spare found
       mly%d: physical device %d:%d initialization started
       mly%d: physical device %d:%d initialization completed
       mly%d: physical device %d:%d initialization failed
       mly%d: physical device %d:%d initialization cancelled
       mly%d: physical device %d:%d write recovery failed
       mly%d: physical device %d:%d scsi bus reset failed
       mly%d: physical device %d:%d double check condition
       mly%d: physical device %d:%d device cannot be accessed
       mly%d: physical device %d:%d gross error on scsi processor
       mly%d: physical device %d:%d bad tag from device
       mly%d: physical device %d:%d command timeout
       mly%d: physical device %d:%d system reset
       mly%d: physical device %d:%d busy status or parity error
       mly%d: physical device %d:%d host set device to failed state
       mly%d: physical device %d:%d selection timeout
       mly%d: physical device %d:%d scsi bus phase error
       mly%d: physical device %d:%d device returned unknown status
       mly%d: physical device %d:%d device not ready
       mly%d: physical device %d:%d device not found at startup
       mly%d: physical device %d:%d COD write operation failed
       mly%d: physical device %d:%d BDT write operation failed
       mly%d: physical device %d:%d missing at startup
       mly%d: physical device %d:%d start rebuild failed due to physical drive
       too small
       mly%d: physical device %d:%d sense data received
       mly%d: sense key %d  asc %02x ascq %02x
       mly%d: info %4D  csi %4D
       mly%d: physical device %d:%d offline
       mly%d: sense key %d  asc %02x ascq %02x
       mly%d: info %4D  csi %4D

       The reported event refers to the physical device  at  the  given  chan-
       nel:target address.

       mly%d: logical device %d (%s) consistency check started
       mly%d: logical device %d (%s) consistency check completed
       mly%d: logical device %d (%s) consistency check cancelled
       mly%d: logical device %d (%s) consistency check completed with errors
       mly%d:  logical device %d (%s) consistency check failed due to logical
       drive failure
       mly%d: logical device %d (%s) consistency check failed due to  physical
       device failure
       mly%d: logical device %d (%s) automatic rebuild started
       mly%d: logical device %d (%s) manual rebuild started
       mly%d: logical device %d (%s) rebuild completed
       mly%d: logical device %d (%s) rebuild cancelled
       mly%d: logical device %d (%s) rebuild failed for unknown reasons
       mly%d:  logical device %d  (%s)  rebuild  failed  due to new physical
       device
       mly%d: logical device %d (%s)  rebuild  failed  due  to logical  drive
       failure
       mly%d: logical device %d (%s) offline
       mly%d: logical device %d (%s) critical
       mly%d: logical device %d (%s) online
       mly%d: logical device %d (%s) initialization started
       mly%d: logical device %d (%s) initialization completed
       mly%d: logical device %d (%s) initialization cancelled
       mly%d: logical device %d (%s) initialization failed
       mly%d: logical device %d (%s) found
       mly%d: logical device %d (%s) gone
       mly%d: logical device %d (%s) expand capacity started
       mly%d: logical device %d (%s) expand capacity completed
       mly%d: logical device %d (%s) expand capacity failed
       mly%d: logical device %d (%s) bad block found
       mly%d: logical device %d (%s) size changed
       mly%d: logical device %d (%s) type changed
       mly%d: logical device %d (%s) bad data block found
       mly%d: logical device %d (%s) read of data block in bdt
       mly%d: logical device %d (%s) write back data for disk block lost

       The event report will include the name of the SCSI device which has at-
       tached to the device if possible.

       mly%d: enclosure %d fan %d failed
       mly%d: enclosure %d fan %d ok
       mly%d: enclosure %d fan %d not present
       mly%d: enclosure %d power supply %d failed
       mly%d: enclosure %d power supply %d ok
       mly%d: enclosure %d power supply %d not present
       mly%d: enclosure %d temperature sensor %d failed
       mly%d: enclosure %d temperature sensor %d critical
       mly%d: enclosure %d temperature sensor %d ok
       mly%d: enclosure %d temperature sensor %d not present
       mly%d: enclosure %d unit %d access critical
       mly%d: enclosure %d unit %d access ok
       mly%d: enclosure %d unit %d access offline

       These  events  refer to external enclosures by number.  The driver does
       not attempt to name the enclosures.

       mly%d: controller cache write back error
       mly%d: controller battery backup unit found
       mly%d: controller battery backup unit charge level low
       mly%d: controller battery backup unit charge level ok
       mly%d: controller installation aborted
       mly%d: controller mirror race recovery in progress
       mly%d: controller mirror race on critical drive
       mly%d: controller memory soft ecc error
       mly%d: controller memory hard ecc error
       mly%d: controller battery backup unit failed

       These events report controller status changes.

AUTHORS
       The mly driver was written by Michael Smith <msmith@FreeBSD.org>.

       This manual page was written by Michael Smith <msmith@FreeBSD.org>.

BUGS
       The driver does not yet provide an external management interface.

       Enclosures are not named or otherwise identified in event messages.

FreeBSD 6.1   August 10, 2004    MLY(4)


NAME | SYNOPSIS | DESCRIPTION | HARDWARE | DIAGNOSTICS | AUTHORS | BUGS

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=mly&sektion=4&manpath=FreeBSD+6.1-RELEASE>
 home | help

 

Legal Notices | © 1995-2026  The FreeBSD Project. All rights reserved.

Contact