1 Construction and operation  



1.1  Failure of mechanical seal  







2 Steam-powered pumps  



2.1  Duplex steam pump  





2.2  Jet injector  







3 See also  





4 References  














Boiler feedwater pump






العربية
Čeština
Deutsch
Hrvatski
Simple English
Srpskohrvatski / српскохрватски
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 




In other projects  



Wikimedia Commons
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


This is the current revision of this page, as edited by Mazewaxie (talk | contribs)at20:59, 8 January 2024 (WP:GENFIXES). The present address (URL) is a permanent link to this version.
(diff)  Previous revision | Latest revision (diff) | Newer revision  (diff)

Aboiler feedwater pump is a specific type of pump used to pump feedwater into a steam boiler. The water may be freshly supplied or returning condensate produced as a result of the condensation of the steam produced by the boiler. These pumps are normally high pressure units that take suction from a condensate return system and can be of the centrifugal pump type or positive displacement type.

Construction and operation[edit]

Feedwater pumps range in size up to many kilowatts and the electric motor is usually separated from the pump body by some form of mechanical coupling. Large industrial condensate pumps may also serve as the feedwater pump. In either case, to force the water into the boiler, the pump must generate sufficient pressure to overcome the steam pressure developed by the boiler. This is usually accomplished through the use of a centrifugal pump. Another common form of feedwater pump runs constantly and is provided with a minimum flow device to stop overpressuring the pump on low flows. The minimum flow usually returns to the tank or deaerator.

Failure of mechanical seal[edit]

Mechanical seals of boiler feedwater pumps often show signs of electrical corrosion. The relative movement between the sliding ring and the stationary ring provokes static charging which is not diverted due to the very low conductivity of the boiler water (below one micro-Siemens per cm [μS/cm]). Within short periods of operation – in some cases, only a few hundred operational hours – pieces having the size of fingertips break off from the sliding and/or the stationary ring and cause rapid increases in leakage current. Diamond-coated (DLC) mechanical seals avoid this problem and extend durability remarkably.[1]

Steam-powered pumps[edit]

Weir feedwater pump

Steam locomotives and the steam engines used on ships and stationary applications such as power plants also require feedwater pumps. In this situation, though, the pump was often powered using a small steam engine that ran using the steam produced by the boiler. A means had to be provided, of course, to put the initial charge of water into the boiler (before steam power was available to operate the steam-powered feedwater pump). The pump was often a positive displacement pump that had steam valves and cylinders at one end and feedwater cylinders at the other end; no crankshaft was required.

Duplex steam pump[edit]

A duplex steam pump has two sets of steam and water cylinders. They are not physically connected but the steam valves on the first pump are operated by the movement of the second pump's piston rod, and vice versa. The result is that there are no "dead spots" and the pump is always self-starting.[2]

Jet injector[edit]

Aninjector pump uses the Venturi effect and steam condensation to deliver water to a boiler.[3]

See also[edit]

References[edit]

  • ^ "Duplex Pump (from Internet Glossary of Pumps)". Animatedsoftware.com. Retrieved 2012-04-22.
  • ^ Strickland Landis Kneass (1894). Practice and Theory of the Injector. John Wiley & Sons (Reprinted by Kessinger Publications, 2007 ). ISBN 978-0-548-47587-4.

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Boiler_feedwater_pump&oldid=1194403314"

    Categories: 
    Fluid dynamics
    Pumps
    Steam boiler components
    Boilers
    Hidden categories: 
    Articles with short description
    Short description is different from Wikidata
    Articles needing additional references from April 2012
    All articles needing additional references
    Articles to be expanded from October 2016
    Commons category link is on Wikidata
     



    This page was last edited on 8 January 2024, at 20:59 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki