1 Operation  





2 Control action  





3 Valve positioners  



3.1  Pneumatic positioners  





3.2  Analog positioners  





3.3  Digital positioners  







4 Types of control valve  



4.1  Based on the pressure drop profile  





4.2  Based on the movement profile of the controlling element  





4.3  Based on the functionality  





4.4  Based on the actuating medium  





4.5  List of common types of control valve  







5 See also  





6 References  





7 External links  














Control valve






Afrikaans
العربية
Català
Deutsch
Español
Euskara
فارسی
Français
Bahasa Indonesia
Italiano
Magyar
Nederlands
Norsk nynorsk
Polski
Русский
Suomi
ி
Türkçe
Українська
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 

(Redirected from Control valves)

Acontrol valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller.[1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure, temperature, and liquid level.

Inautomatic control terminology, a control valve is termed a "final control element".

Operation[edit]

Air-actuated control valves each with a 4–20 mA "I to P" converter integral to a valve positioner. In this example each positioner is comparing the valve stem travel against control signal, and applying any correction.

The opening or closing of automatic control valves is usually done by electrical, hydraulicorpneumatic actuators. Normally with a modulating valve, which can be set to any position between fully open and fully closed, valve positioners are used to ensure the valve attains the desired degree of opening.[2]

Air-actuated valves are commonly used because of their simplicity, as they only require a compressed air supply, whereas electrically operated valves require additional cabling and switch gear, and hydraulically actuated valves required high pressure supply and return lines for the hydraulic fluid.

The pneumatic control signals are traditionally based on a pressure range of 3–15 psi (0.2–1.0 bar), or more commonly now, an electrical signal of 4-20mA for industry, or 0–10 V for HVAC systems. Electrical control now often includes a "Smart" communication signal superimposed on the 4–20 mA control current, such that the health and verification of the valve position can be signalled back to the controller. The HART, Fieldbus Foundation, and Profibus are the most common protocols.

An automatic control valve consists of three main parts in which each part exist in several types and designs:

Control action[edit]

Showing the evolution of analogue control loop signalling from the pneumatic era to the electronic era.
Example of current loops used for sensing and control transmission. Specific example of a smart valve positioner used.
Globe control valve with pneumatic diaphragm actuator and "smart" positioner which will also feed back to the controller the actual valve position

Taking the example of an air-operated valve, there are two control actions possible:

There can also be failure to safety modes:

The modes of failure operation are requirements of the failure to safety process control specification of the plant. In the case of cooling water it may be to fail open, and the case of delivering a chemical it may be to fail closed.

Valve positioners[edit]

The fundamental function of a positioner is to deliver pressurized air to the valve actuator, such that the position of the valve stem or shaft corresponds to the set point from the control system. Positioners are typically used when a valve requires throttling action. A positioner requires position feedback from the valve stem or shaft and delivers pneumatic pressure to the actuator to open and close the valve. The positioner must be mounted on or near the control valve assembly. There are three main categories of positioners, depending on the type of control signal, the diagnostic capability, and the communication protocol: pneumatic, analog, and digital.[3]

Pneumatic positioners[edit]

Processing units may use pneumatic pressure signaling as the control set point to the control valves. Pressure is typically modulated between 20.7 and 103 kPa (3 to 15 psig) to move the valve from 0 to 100% position. In a common pneumatic positioner, the position of the valve stem or shaft is compared with the position of a bellows that receives the pneumatic control signal. When the input signal increases, the bellows expands and moves a beam. The beam pivots about an input axis, which moves a flapper closer to the nozzle. The nozzle pressure increases, which increases the output pressure to the actuator through a pneumatic amplifier relay. The increased output pressure to the actuator causes the valve stem to move.

Stem movement is fed back to the beam by means of a cam. As the cam rotates, the beam pivots about the feedback axis to move the flapper slightly away from the nozzle. The nozzle pressure decreases and reduces the output pressure to the actuator. Stem movement continues, backing the flapper away from the nozzle until equilibrium is reached. When the input signal decreases, the bellows contracts (aided by an internal range spring) and the beam pivots about the input axis to move the flapper away from the nozzle. Nozzle decreases and the relay permits the release of diaphragm casing pressure to the atmosphere, which allows the actuator stem to move upward.

Through the cam, stem movement is fed back to the beam to reposition the flapper closer to the nozzle. When equilibrium conditions are obtained, stem movement stops and the flapper is positioned to prevent any further decrease in actuator pressure.[3]

Analog positioners[edit]

The second type of positioner is an analog I/P positioner. Most modern processing units use a 4 to 20 mA DC signal to modulate the control valves. This introduces electronics into the positioner design and requires that the positioner convert the electronic current signal into a pneumatic pressure signal (current-to-pneumatic or I/P). In a typical analog I/P positioner, the converter receives a DC input signal and provides a proportional pneumatic output signal through a nozzle/flapper arrangement. The pneumatic output signal provides the input signal to the pneumatic positioner. Otherwise, the design is the same as the pneumatic positioner[3]

Digital positioners[edit]

While pneumatic positioners and analog I/P positioners provide basic valve position control, digital valve controllers add another dimension to positioner capabilities. This type of positioner is a microprocessor-based instrument. The microprocessor enables diagnostics and two-way communication to simplify setup and troubleshooting.

In a typical digital valve controller, the control signal is read by the microprocessor, processed by a digital algorithm, and converted into a drive current signal to the I/P converter. The microprocessor performs the position control algorithm rather than a mechanical beam, cam, and flapper assembly. As the control signal increases, the drive signal to the I/P converter increases, increasing the output pressure from the I/P converter. This pressure is routed to a pneumatic amplifier relay and provides two output pressures to the actuator. With increasing control signal, one output pressure always increases and the other output pressure decreases

Double-acting actuators use both outputs, whereas single-acting actuators use only one output. The changing output pressure causes the actuator stem or shaft to move. Valve position is fed back to the microprocessor. The stem continues to move until the correct position is attained. At this point, the microprocessor stabilizes the drive signal to the I/P converter until equilibrium is obtained.

In addition to the function of controlling the position of the valve, a digital valve controller has two additional capabilities: diagnostics and two-way digital communication.[3]

Widely used communication protocols include HART, FOUNDATION fieldbus, and PROFIBUS.

Advantages of placing a smart positioner on a control valve:

Types of control valve[edit]

Control valves are classified by attributes and features.

Based on the pressure drop profile[edit]

Based on the movement profile of the controlling element[edit]

Based on the functionality[edit]

Based on the actuating medium[edit]

A wide variety of valve types and control operation exist. However, there are two main forms of action, the sliding stem and the rotary.

The most common and versatile types of control valves are sliding-stem globe, V-notch ball, butterfly and angle types. Their popularity derives from rugged construction and the many options available that make them suitable for a variety of process applications.[5] Control valve bodies may be categorized as below:[3]

List of common types of control valve[edit]

See also[edit]

  • Control engineering – Engineering discipline that deals with control systems
  • Control system – System that manages the behavior of other systems
  • Distributed control system – Computerized control systems with distributed decision-making
  • Fieldbus Foundation
  • Flow control valve – Valve that regulates the flow or pressure of a fluid
  • Highway Addressable Remote Transducer Protocol, also known as HART Protocol – Industrial automation protocol
  • Instrumentation – Measuring instruments which monitor and control a process
  • PID controller – Control loop feedback mechanism
  • Process control – Discipline that uses industrial control to achieve a production level of consistency
  • Profibus – Communications protocol
  • SCADA, also known as Supervisory control and data acquisition system – Control system architecture for supervision of machines and processes
  • References[edit]

    1. ^ Instrument Society of America Standard S561.1, 1976. as reproduced in the "Fisher control valve handbook" fourth edition 1977. Current: Fourth Edition
  • ^ "What is Control Valve & How Does it Works | Aira Valve". 2020-10-07. Retrieved 2022-12-17.
  • ^ a b c d e Emerson Automation Solutions (2017). "Control Valve Handbook" (PDF) (5th ed.). Fischer Controls International LLC. Retrieved 2019-05-04.
  • ^ "What is Globe Valve? Working Principle & Function | Linquip". www.linquip.com. Retrieved 2021-11-25.
  • ^ Hagen, S. (2003) "Control valve technology" Plant Services
  • External links[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Control_valve&oldid=1224140151"

    Categories: 
    Control devices
    Valves
    Hidden categories: 
    Articles with short description
    Short description is different from Wikidata
    Pages displaying short descriptions of redirect targets via Module:Annotated link
     



    This page was last edited on 16 May 2024, at 13:52 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki