1 Determination  





2 References  














Diagnostically acceptable irreversible compression







Add links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 

(Redirected from Diagnostically Acceptable Irreversible Compression)

Diagnostically acceptable irreversible compression (DAIC) is the amount of lossy compression which can be used on a medical image to produce a result that does not prevent the reader from using the image to make a medical diagnosis.

The term was first introduced at a workshop on irreversible compression convened by the European Society of Radiology (ESR) in Palma de Mallorca October 13, 2010, the results of which were reported in a subsequent position paper.[1]

Determination[edit]

The "amount of compression" in irreversible compression used to be determined by the compression ratio, where the acceptable minimum is determined by the algorithm (typically JPEGorJ2K) and the data type (body part and imaging method). Such a definition is easy to follow, and has been used by medical bodies in 2010 around the world.[1]

However, its downside is obvious: the compression ratio tells nothing about the real quality of the image, as different compressors can produce vastly different qualities under the same file size.[1] For example, the JPEG format of 1992 can perform as well as many modern formats given newer techniques exploited in mozjpeg and ISO libjpeg, yet they would be lumped together with the legacy encoders in such a scheme.[2]

The image compression community has long used objective quality metrics like SSIM to measure the effects of compression. In the absence of good data regarding SSIM, the ESR review of 2010 concluded that it is still difficult to establish a criterion for whether a particular irreversible compression scheme applied with particular parameters to a particular individual image, or category of images, avoids the introduction of some quantifiable risk of a diagnostic error for any particular diagnostic task.[1]

An 2017 study showed that a SSIM variant called 4-G-r* (4-component, gradient, structural component of SSIM) best reflects changes in images that affect the decision of radiologists out of 16 SSIM variants.[3] An 2020 study shows that visual information fidelity (VIF), feature similarity index (FSIM), and noise quality metric (NQM) best reflect radiologist preferences out of ten metrics. It also mentions that the original version of SSIM works as poorly as a basic root-mean-square distance (RMSD) for this purpose, a result echoed by the 2017 study. The 4-G-r* modification is not tested in the study.[4]

References[edit]

  1. ^ a b c d European Society of Radiology (April 2011). "Usability of irreversible image compression in radiological imaging. A position paper by the European Society of Radiology (ESR)". Insights into Imaging. 2 (2): 103–115. doi:10.1007/s13244-011-0071-x. PMC 3259360. PMID 22347940.
  • ^ Richter, Thomas (September 2016). "JPEG on STEROIDS: Common optimization techniques for JPEG image compression". 2016 IEEE International Conference on Image Processing (ICIP). pp. 61–65. doi:10.1109/ICIP.2016.7532319. ISBN 978-1-4673-9961-6. S2CID 14922251.
  • ^ Renieblas, Gabriel Prieto; Nogués, Agustín Turrero; González, Alberto Muñoz; Gómez-Leon, Nieves; del Castillo, Eduardo Guibelalde (26 July 2017). "Structural similarity index family for image quality assessment in radiological images". Journal of Medical Imaging. 4 (3): 035501. doi:10.1117/1.JMI.4.3.035501. PMC 5527267. PMID 28924574.
  • ^ Mason, A; Rioux, J; Clarke, SE; Costa, A; Schmidt, M; Keough, V; Huynh, T; Beyea, S (April 2020). "Comparison of Objective Image Quality Metrics to Expert Radiologists' Scoring of Diagnostic Quality of MR Images". IEEE Transactions on Medical Imaging. 39 (4): 1064–1072. doi:10.1109/TMI.2019.2930338. PMID 31535985.

  • t
  • e

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Diagnostically_acceptable_irreversible_compression&oldid=1170304777"

    Categories: 
    Medical imaging
    Image processing
    Nuclear medicine
    Medical imaging stubs
    Hidden category: 
    All stub articles
     



    This page was last edited on 14 August 2023, at 08:18 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki