1 Dropping mercury electrode  



1.1  Structure  





1.2  Considerations  







2 Hanging mercury drop electrode  



2.1  Distinction  







3 See also  





4 References  














Liquid metal electrode







Add links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 

(Redirected from Dropping mercury electrode)

Aliquid metal electrode is an electrode that uses a liquid metal, such as mercury, Galinstan, and NaK.[not verified in body] They can be used in electrocapillarity, voltammetry, and impedance measurements.[1]

Dropping mercury electrode[edit]

Dropping mercury electrode

The dropping mercury electrode (DME) is a working electrode made of mercury and used in polarography. Experiments run with mercury electrodes are referred to as forms of polarography even if the experiments are identical or very similar to a corresponding voltammetry experiment which uses solid working electrodes. Like other working electrodes these electrodes are used in electrochemical studies using three electrode systems when investigating reaction mechanisms related to redox chemistry among other chemical phenomena.[2][3][4][5][6]

Structure[edit]

A flow of mercury passes through an insulating capillary producing a droplet which grows from the end of the capillary in a reproducible way. Each droplet grows until it reaches a diameter of about a millimeter and releases. The released droplet is no longer in contact with the working electrode whose contact is above the capillary. As the electrode is used mercury collects in the bottom of the cell. In some cell designs this mercury pool is connected to a lead and used as the cell's auxiliary electrode. Each released drop is immediately followed by the formation of another drop. The drops are generally produced at a rate of about 0.2 Hz.

Considerations[edit]

A major advantage of the DME is that each drop has a smooth and uncontaminated surface free from any adsorbed analyte or impurity. The self-renewing electrode does not need to be cleaned or polished like a solid electrode. This advantage comes at the cost of a working electrode with a constantly changing surface area. Since the drops are produced predictably the changing surface area can be accounted for or even used advantageously. In addition, the drops' growth causes more and more addition of capacitive current to the faradaic current. These changing current effects combined with experiments where the potential is continuously changed can result in noisy traces. In some experiments the traces are continually sampled, showing all the current deviation resulting from the drop growth. Other sampling methods smooth the data by sampling the current at the electrode only once per drop at a specific size. The DME's periodic expansion into the solution and hemispherical shape also affects the way the analyte diffuses to the electrode surface. The DME consists of a fine capillary with a bore size of 20–50 μm.

Hanging mercury drop electrode[edit]

Hanging Mercury Drop
Hanging mercury drop electrode

The hanging mercury drop electrode (HMDE) is a working electrode variation on the dropping mercury electrode (DME). It was developed by Polish chemist Wiktor Kemula.[7] Experiments run with dropping mercury electrodes are referred to as forms of polarography. If the experiments are performed at an electrode with a constant surface (like the HMDE) it is referred as voltammetry.

Like other working electrodes these electrodes are used in electrochemical studies using three electrode systems when investigating reaction mechanisms related to redox chemistry among other chemical phenomenon.[8][9][10][11]

Distinction[edit]

The hanging mercury drop electrode produces a partial mercury drop of controlled geometry and surface area at the end of a capillary in contrast to the dropping mercury electrode which steadily releases drops of mercury during an experiment. The disadvantages a DME experiences due to a constantly changing surface are not experienced by the HMDE since it has static surface area during an experiment. The static surface of the HMDE means it is more likely to suffer from the surface adsorption phenomenon than a DME. Unlike solid electrodes which need to be cleaned and polished between most experiments, the self-renewing HMDE can simply release the contaminated drop and grow a clean drop between each experiment.

See also[edit]

References[edit]

  1. ^ Doubova, L. M.; De Battisti, A.; Fawcett, W. R. (2003-10-01). "Adsorption of C-5 Nitriles at Liquid Metal Electrodes. A Comparison of Adsorption Parameters for Isovaleronitrile at Polarized Surfaces of Mercury and Indium–Gallium Alloy (Eutectic Composition)". Langmuir. 19 (22): 9276–9283. doi:10.1021/la0346447. ISSN 0743-7463.
  • ^ Bard, Allen J.; Larry R. Faulkner (2000-12-18). Electrochemical Methods: Fundamentals and Applications (2 ed.). Wiley. ISBN 978-0-471-04372-0.
  • ^ Zoski, Cynthia G. (2007-02-07). Handbook of Electrochemistry. Elsevier Science. ISBN 978-0-444-51958-0.
  • ^ Kissinger, Peter; William R. Heineman (1996-01-23). Laboratory Techniques in Electroanalytical Chemistry, Second Edition, Revised and Expanded (2 ed.). CRC. ISBN 978-0-8247-9445-3.
  • ^ Skoog, Douglas A.; F. James Holler; Timothy A. Nieman (1997-09-03). Principles of Instrumental Analysis (5 ed.). Brooks Cole. ISBN 978-0-03-002078-0.
  • ^ Baars, A.; M. Sluyters-Rehbach; J. H. Sluyters (January 1994). "Application of the dropping mercury microelectrode (DMμE) in electrode kinetics and electroanalysis". Journal of Electroanalytical Chemistry. 364 (1–2): 189–197. doi:10.1016/0022-0728(93)02918-8.[dead link]
  • ^ R. Narayan. "The hanging mercury drop electrode". sciencedirect.com. Retrieved 13 November 2023.
  • ^ Bard, Allen J.; Larry R. Faulkner (2000-12-18). Electrochemical Methods: Fundamentals and Applications (2 ed.). Wiley. ISBN 978-0-471-04372-0.
  • ^ Zoski, Cynthia G. (2007-02-07). Handbook of Electrochemistry. Elsevier Science. ISBN 978-0-444-51958-0.
  • ^ Kissinger, Peter; William R. Heineman (1996-01-23). Laboratory Techniques in Electroanalytical Chemistry, Second Edition, Revised and Expanded (2 ed.). CRC. ISBN 978-0-8247-9445-3.
  • ^ Skoog, Douglas A.; F. James Holler; Timothy A. Nieman (1997-09-03). Principles of Instrumental Analysis (5 ed.). Brooks Cole. ISBN 978-0-03-002078-0.

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Liquid_metal_electrode&oldid=1228971263#Dropping_mercury_electrode"

    Category: 
    Electrodes
    Hidden categories: 
    All articles with dead external links
    Articles with dead external links from March 2019
    Articles with short description
    Short description is different from Wikidata
    Wikipedia introduction cleanup from July 2022
    All pages needing cleanup
    Articles covered by WikiProject Wikify from July 2022
    All articles covered by WikiProject Wikify
    All articles with unsourced statements
    Articles with unsourced statements from July 2022
     



    This page was last edited on 14 June 2024, at 04:44 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki