1 Description  





2 Devices  



2.1  Hydropneumatic suspension  





2.2  Hydropneumatic lock  





2.3  Hydropneumatic recoil mechanism  





2.4  Hydropneumatic water hammer preventers  





2.5  Hydropneumatic pump controllers  





2.6  Hydropneumatic pulsation filters  





2.7  Hydropneumatic acceleration head reducers  





2.8  Pulsation dampeners  



2.8.1  Misuse of the term  







2.9  Hydropneumatic accumulators  



2.9.1  Non-hydropneumatic  









3 References  














Hydropneumatic device







Add links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 

(Redirected from Hydropneumatic)

Hydropneumatic devices (orhydro-pneumatic devices) are systems that operate using water and gas. The devices are used in various applications.

Description[edit]

A hydropneumatic device is a tool that functions by using using water and gas.[1] Hydropneumatic refers to the pneumatic (gas) and hydraulic (water) components needed for operation of the devices.

Hydropneumatic accumulators or pulsation dampeners are devices which prevent, but do not absorb, alleviate, arrest, attenuate, or suppress a shock that already exists, meaning that these devices prevent the creation of a shock wave at an otherwise earlier stage. These can include pulsation dampeners, hydropneumatic accumulators, water hammer preventers, water hammer arrestors, and other things.

Devices[edit]

Hydropneumatic suspension[edit]

Hydropneumatic lock[edit]

Hydropneumatic recoil mechanism[edit]

Hydropneumatic water hammer preventers[edit]

Hydropneumatic water hammer preventers are chambers of sufficient volume to allow an extension of time in which a given flow may be accelerated or decelerated without sudden large change in pressure. See also expansion tank. When shock waves of an incompressible fluid within a piping system exist, especially at a high velocity, there is a high chance for water hammer. To help prevent a swing check from slamming and causing water hammer, a spring-assisted non-slam check valve is installed. Rather than relying on flow or gravity to be closed, the non-slam design prevents a sudden velocity decrease and reverse flow.[2]

The hydropneumatic water hammer preventer chamber is generally adapted to contain a separator member which prevents the escape of a pre-filled compressed inert gas. They may be

  1. Placed closely before a valve that is closed quickly. Stops water hammering.
  2. Placed immediately after the discharge of a pump that is started fast into a pipe full of a long column of liquid. Reduces start up surge pressure.
  3. Placed immediately after a pump, which when caused to stop suddenly, enables a vacuum to form, which pulls the flow back towards the pump. Prevents an implosion bang.

Variations on the design include

  1. Having a separator membrane into the interior of which the liquid is communicated. Used for corrosive liquids, so that the chamber metal can be of low cost.
  2. Having a metal bellows separator membrane for use at low and higher temperatures than are compatible with an elastomeric or plastomeric[check spelling] membrane.
  3. Having a float separator to reduce the rate of gas absorption at the liquid interface, typically used in vessel chambers larger than 500 gallons.

Hydropneumatic pump controllers[edit]

Hydropneumatic pump controllers provide a

  1. Means of control for multiple fixed delivery volume, low cost low complexity pumps; to provide variable flow as required by small (say +/- 10 psi) pressure increase or decrease of a system.
  2. Means of control for pump unloading / recirculation against no pressure, without electric pressure switches.

The controllers are pressure cylinders containing a movable separator member between a gas and a liquid, said moveable member causing the actuation of directional control valve or valves. The controllers are used in a circuit after a pump that is followed by a valved-side branch, and beyond a check valve, so that this device can only discharge liquid volume by a pressure fall of the system.

Variations on the design include

  1. Having a protruding drive rod, cams from which trip valve handles.
  2. Having magnetically actuated reed switched.
  3. Having infrared signaling of separator position.

Hydropneumatic pulsation filters[edit]

Hydropneumatic pulsation filters provide means of reducing the amplitude of pressure changes the velocity of which is in the order of 1.4 km/s. All are used in industry.

A hydropneumatic pulsation filter is a pressure container with separate inlet and outlet, connectable to a pipe system so that all pressure changes must attempt to pass through said chamber. Entry and exit of said chamber being of a diameter relative to chamber diameter that provides a high discharge coefficient, and without close proximity of any reflective surface. Lack of any sudden change in cross section area of flow path that would reflect a pressure wave, i.e. no orifice plate(s). Variations include Combination "dual purpose" devices addressing "acceleration head reduction" by means of a gas containment.

The devices have applications by frequency response

Hydropneumatic acceleration head reducers[edit]

Hydropneumatic acceleration head reducers minimize the mass of liquid that has to be accelerated when flow velocity changes. Within a piping system, pressure rises when a volume of fluid becomes present. This acceleration head needs to be reduced to prevent damage to pump components and excessive noise.[3] These devices are typically mountable in any orientation such that the device is connectable directly to the suction check valve beneath the pump or directly to any vertical or horizontal discharge check valve; minimizing the length of any liquid column mass that will experience velocity change. Pump connection being separate from system connection so that no acceleration head changes occur due to reciprocation within one port.

Applications for hydropneumatic acceleration head reducers include

  1. Reduction in drive energy costs required by any pump.
  2. Reduction in pipe diameter and schedule (wall thickness) costs of any pipe system.
  3. Decrease in fatigue and increase in safety of all pressure piping systems.
  4. Increase in accuracy and automatability of all pressure and flow control instruments.
  5. Increase in rotating equipment life and MTBF.
  6. Reduction in service down time.

Variations on the design include

  1. For chemicals and process pump systems: having PTFE membranes.
  2. For sludges and slurries: having a clear unobstructed flow path direct from in to out.
  3. For general purposes: having an elastomeric bladder separator.

Pulsation dampeners[edit]

Misuse of the term[edit]

Some manufacturers of pulsation dampeners provide items which do not dampen pulsations. The compressibility of a gas, often nitrogen because it is inert at normal temperatures, stores any sudden volume change. Storing sudden volume change enables volume to change against a soft gas cushion, without the need to accelerate all the existing liquid in the system out of the way of the new volume coming from a pump. Therefore, as all the volume in a system does not have to be suddenly accelerated, the cushion is preventing "acceleration head" (force) having to be generated. The pressure pulse is accordingly not generated in the first place, so it is not dampened at all. The gas cushion simply allows volume change to be stored. The manufacturers are providing, are liquid accumulators, not an item which removes energy.

Hydropneumatic accumulators[edit]

Gas cushion (spring) pre-filled accumulators of liquids are called hydropneumatic accumulators. "Hydro" because a liquid (like water) is involved. "Pneumatic" because a gas (like air) is involved. "Accumulator" because the purpose is to store or accumulate liquid volume by easy compression of the gas. These devices are typified by having only one liquid connection that goes to a "T" on the system.

Non-hydropneumatic[edit]

There are other forms of accumulator used for fluid power hydraulic purposes. For example, coil spring plus sealed piston; though these are less popular. Therefore, a hydraulic accumulator is not necessarily a hydropneumatic accumulator.

References[edit]

  1. ^ "Definition of HYDROPNEUMATIC". www.merriam-webster.com. Retrieved 2024-01-17.
  • ^ "Preventing Water Hammer". DFT Inc. Retrieved 4 January 2016.
  • ^ David McComb (28 April 2014). "Sizing Pulsation Dampeners Is Critical to Effectiveness". Pumps & Systems. Retrieved 4 January 2016.

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Hydropneumatic_device&oldid=1196280875"

    Category: 
    Hydraulics
    Hidden categories: 
    Articles needing expert attention from November 2008
    All articles needing expert attention
    Technology articles needing expert attention
    Articles needing additional references from February 2017
    All articles needing additional references
    Articles with multiple maintenance issues
    All articles with unidentified words
    Articles with unidentified words from November 2019
     



    This page was last edited on 17 January 2024, at 00:53 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki