Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Class 0  





2 Class I  





3 Class 0I  





4 Class II  





5 Class IIFE  





6 Class III  





7 See also  





8 References  





9 Sources  














Appliance classes






Català
Deutsch
Eesti
Español
فارسی
Français
Italiano
Bahasa Melayu
Nederlands

Polski
Português
Русский
Suomi
Українська
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 

(Redirected from IEC 60536-2)

Appliance classes (also known as protection classes) specify measures to prevent dangerous contact voltages on unenergized parts, such as the metallic casing, of an electronic device. In the electrical appliance manufacturing industry, the following appliance classes are defined in IEC 61140 and used to differentiate between the protective-earth connection requirements of devices.

Class 0

[edit]

These appliances have no protective-earth connection and feature only a single level of insulation between live parts and exposed metalwork. If permitted at all, Class 0 items are intended for use in dry areas only. A single fault could cause an electric shock or other dangerous occurrence, without triggering the automatic operation of any fuse or circuit breaker. Sales of such items have been prohibited in much of the world for safety reasons, for example in the UK by Section 8 of The Low Voltage Electrical Equipment (Safety) Regulations 1989 and New Zealand by the Electricity Act. A typical example of a Class 0 appliance is the old style of Christmas fairy lights. However, equipment of this class is common in some 120 V countries, and in much of the 230 V developing world, whether permitted officially or not. These appliances do not have their chassis connected to electrical earth. In many countries the plug of a class 0 equipment is such that it cannot be inserted to grounded outlet like Schuko. The failure of such an equipment in a location where there are grounded equipment can cause fatal shock if one touches both. Any Class 1 equipment will act like a Class 0 equipment when connected to an ungrounded outlet.

Class I

[edit]
Green ground wire with yellow stripe
Symbol used to mark the Protective Earthing Conductor terminal of Class I equipment

Appliance class I is not only based on the basic insulation, but the casing and other conductive parts are also connected with a low-resistant earth conductor. Hence, these appliances must have their chassis connected to electrical earth (US: ground) by a separate earth conductor (coloured green/yellow in most countries, green in India, USA, Canada and Japan). The earth connection is achieved with a three-conductor mains cable, typically ending with three-prong AC connector which plugs into a corresponding AC outlet.

Plugs are designed such that the connection to the protective earth conductor should be the first connection when plugged in. It should also be the last to be broken when the plug is removed.[1]

A fault in the appliance which causes a live conductor to contact the casing will cause a current to flow in the earth conductor. If large enough, this current will trip an over-current device (fuseorcircuit breaker [CB]) and disconnect the supply. The disconnection time has to be fast enough not to allow fibrillation to start if a person is in contact with the casing at the time. This time and the current rating in turn sets a maximum earth resistance permissible. To provide supplementary protection against high-impedance faults it is common to recommend a residual-current device (RCD) also known as a residual current circuit breaker (RCCB), ground fault circuit interrupter (GFCI), or residual current operated circuit-breaker with integral over-current protection (RCBO), which will cut off the supply of electricity to the appliance if the currents in the two poles of the supply are not equal and opposite.

Class 0I

[edit]

Electrical installations where the chassis is connected to earth with a separate terminal, instead of via the mains cable. In effect this provides the same automatic disconnection as Class I, for equipment that otherwise would be Class 0.

Class II

[edit]
Class II symbol

A Class II or double insulated electrical appliance uses reinforced protective insulation in addition to basic insulation. Hence, it has been designed in such a way that it does not require a safety connection to electrical earth (ground).

The basic requirement is that no single failure can result in dangerous voltage becoming exposed so that it might cause an electric shock and that this is achieved without relying on an earthed metal casing. This is usually achieved at least in part by having at least two layers of insulating material between live parts and the user, or by using reinforced insulation.

InEurope, a double insulated appliance must be labelled Class IIordouble insulated or bear the double insulation symbol: ⧈ (a square inside another square). As such, the appliance should not be connected to an earth conductor because the high-impedance casing will cause only low-fault currents that are unable to trigger the fusible cut-out.[1]

Insulated AC/DC power supplies (such as cell-phone chargers) are typically designated as Class II, meaning that the DC output wires are isolated from the AC input. The designation "Class II" should not be confused with the designation "Class 2", as the latter is unrelated to insulation (it originates from standard UL 1310, setting limits on maximum output voltage/current/power).

Class IIFE

[edit]

[1]

These devices have a Functional Earth "FE". This differs from a protective earth ground in that it does not offer shock protection from a hazardous voltage. However, it does help to mitigate electromagnetic noise or EMI. This is often important in Audio and Medical design. Note as they also include double insulation it means that users will not be able to come into contact with any live parts.

Class III

[edit]
Class III symbol

A Class III appliance is designed to be supplied from a separated extra-low voltage (SELV) power source. The voltage from a SELV supply is low enough such that under normal conditions a person can safely come into contact with an energized conductor without risk of electrical shock. The additional safety features required by Class I and Class II appliances are therefore not required. Specifically, Class III appliances are designed without an earth conductor and should not be connected to the earth grounding of the SELV power source.[1][why?] For medical devices, compliance with Class III is not considered sufficient protection, and furthermore, stringent regulations apply to such equipment.[2]

The Class III label does not guarantee a device's safety in any aspect other than electrical shock. Even at low voltages, abusive or unintended use (such as disassembly or incorrect installation[3]) may still yield dangerous outcomes. Although there should be no risk of receiving an electrical shock from Class III appliances, other electrical hazards (such as overheating and fire) must still be considered. For instance, a laptop or mobile phone might qualify as a Class III appliance if it is charged via an external SELV adapter, even though the onboard battery could pose a fire risk.

See also

[edit]

References

[edit]
  1. ^ a b c J. Lienig; H. Bruemmer (2017). "Sec. 3.4.2 Protection Classes". Fundamentals of Electronic Systems Design. Springer International Publishing. pp. 40–41. doi:10.1007/978-3-319-55840-0. ISBN 978-3-319-55839-4.
  • ^ Great Britain, Health and Safety Executive Staff (2015-10-31). Electricity at Work Regulations 1989. HSE Books. ISBN 9780717666362.
  • ^ Anker Innovations Limited. "Manual for Anker PowerCore 20000 PD" (PDF). Retrieved 3 August 2022.
  • Sources

    [edit]
    Retrieved from "https://en.wikipedia.org/w/index.php?title=Appliance_classes&oldid=1224783439"

    Categories: 
    Electric power
    IEC standards
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
    Articles needing additional references from June 2022
    All articles needing additional references
    Wikipedia articles needing clarification from May 2024
     



    This page was last edited on 20 May 2024, at 12:43 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki