1 Role of airport fire services  





2 Levels of fire cover  





3 Levels of response  





4 Rank structure  





5 Other incidents  





6 Fire appliances  





7 Training  





8 References  














Airport rescue and firefighting services in the United Kingdom







Add links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


The provision of rescue and firefighting services (RFFS) at all airports and aerodromes in the United Kingdom is a requirement under British law and under international agreements[which?] set out by the International Civil Aviation Organization.

In the UK airport fire services are usually referred to as "rescue and firefighting services" in contrast to the term "fire and rescue service" (FRS) used by local authority fire services.

Role of airport fire services[edit]

The principal objective of an airport fire and rescue service is "to save lives in the event of an aircraft accident or incident". This also applies to any other incident where life and property can be saved.

Levels of fire cover[edit]

The number and type of firefighting appliances based at an airport will be determined by the airport's category and task and resource analysis (TRA).

Airports in the UK are categorised from 1 to 10 dependent on the type and size of aircraft they handle.[1]

A category 10 airport caters for the biggest aircraft, namely the Airbus A380, and therefore requires extensive rescue and firefighting cover as determined by the Civil Aviation Authority.

Often the RFFS will also be responsible for providing medical cover at the airport. The majority of UK airport firefighters are trained to emergency medical technician status.

Levels of response[edit]

The airport RFFS will respond to all aircraft emergencies within the airport's boundaries and will also respond to off-airport incidents that fall within a 6-degree cone from the end of each runway. If a special request has been made by the local authority, then dependent on circumstances, major foam tenders may be dispatched.

All incidents that occur outside of the airport boundary are the responsibility of the local authority fire and rescue service serving that location.

Whilst local authority FRS firefighters are trained to deal with aircraft accidents they do not receive the same level of training as airport firefighters whose expertise is more specialist.

Rank structure[edit]

For the most part, a RFFS follows the same rank structure as a local authority FRS. Senior officers, however, are given slightly different titles. The highest-ranking airport fire officer is known as an "AFM" (airport fire manager). Depending on the service the senior officer may also be referred to as the chief fire officer or the senior airport fire officer (SAFO).

There is mainly a five rank structure at the majority of UK airports;

AFM Airport fire manager Assumes overall control of the fire crews/station
STM Station/watch manager Assumes control of the daily needs of the station
CM Crew manager Assumes control of the daily duties & training of the crews
CC Crew commander Takes the lead roles at an incident BA-ECO and/or BA team leader
FF Firefighter Carries out duties as delegated by CM/CC

This list of rank structure is not exhaustive or limited – other airports may adopt more ranks, especially larger aerodromes (Cat6+).

Other incidents[edit]

Like any modern FRS, airport crews will deal with road traffic collisions on airport property, as well as chemical spillages, fires/rescues in airport buildings and special service calls on-site if resourced with a form of domestic vehicle/facilities.

Some incidents are wherever possible passed onto the local authority fire service so that the airport crews can return to give fire cover to the runway.

Large airport fire services such as that based at Heathrow Airport have sufficient personnel and vehicles to deal with most emergencies on-site, although the LAFRS are called to most incidents as support and/or lead agency.

When an airport is located near a body of water such as a river, the airport fire service will be required to operate a water rescue service. London City Airport FRS, for example, are capable of performing advanced water rescue and is equipped with several rescue craft for dealing with aircraft incidents in the surrounding Docklands area.

Fire appliances[edit]

Rosenbauer Panther at Farnborough Airfield during the 2008 Farnborough Airshow
Manchester Airport Fire Engine - Scania P124C 420
Two Land Rover-based fire tenders at Caernarfon Airport
Crash tender at Oxford Airport

The number and type of firefighting appliances based at an airport will be determined by the airport's category. Airports in the UK are categorised from 1 to 10, dependent on the type and size of aircraft they handle, so a category 10 airport caters for the biggest aircraft and therefore requires extensive rescue and firefighting cover as determined by the TRA.

The fire appliances used by airport fire and rescue services normally consist of a fleet of large high-volume pumping vehicles capable of carrying an enormous amount of foam, or other fire extinguishing media and equipment on bulk, and then applying it under massive pressure and volume at the fire scene.

Most airport fire appliances are equipped with a roof-mounted high volume 'monitor' or 'nozzle' which can shoot fire extinguishing media huge distances. This means that an approaching fire appliance can begin tackling flames before it has arrived close to the scene of the fire.

A new type of roof-mounted monitor has been introduced in the UK; commonly known as a 'snozzle', it consists of an extensible boom capable of reaching the upper decks of the A380 to extinguish fires and is equipped with an infra-red camera, a variable output 'nozzle' and a device resembling a spike that can pierce the fuselage of an aircraft and deliver large amounts of water and foam inside the aircraft. This makes airport firefighting safer as firefighters do not need to set foot inside the aircraft to extinguish fires, as they can do it from the safety of their fire appliance using the snozzle.

Because of their sheer size, airport fire appliances require powerful engines to propel them. In fact, by law, the airport fire appliances should be capable of reaching any incident within the airport (including the predetermined boundaries outside of the airport) within three minutes (as set by the CAA).

Augmenting the capability of the huge fire appliances are vehicles known as either first attack/first strike or rapid intervention vehicles.

They are capable of arriving at the scene of an incident much quicker to begin rescue or firefighting operations. Such appliances vary from small Range Rover-based fire appliances to much larger truck-based pumps.

In larger airports, the rapid intervention vehicles and high volume pumping appliance (volumes up to 5,000 litres/minute) are supported by "domestic" type fire appliances similar to those used by the local authority FRS.

They are mainly used to respond to emergencies within the buildings around the airport, but also assist at aircraft incidents.

A typical category 10 airport, such as London Heathrow, operates out of two fire stations (located in the east and west of the airport) in order to achieve the three-minute response time to any location within the airport boundary. Each station operates a Scania domestic pump, two six-wheel-drive major foam tenders and a similar but smaller four-wheel-drive light foam tender. The Heathrow FRS also operates two Mitsubishi Shogun command vehicles out of the main fire station, a Scania hose-layer, several auxiliary vehicles (such as a personnel carrier) along with a couple of reserve foam tenders and, to meet category 10 requirements, a Scania 42 m aerial ladder platform to reach the upper deck of the A380.

Training[edit]

ICAO Annex 14, § 9.2.34 directs that: All rescue and firefighting personnel shall be properly trained to perform their duties in an efficient manner and shall participate in live fire-drills commensurate with the types of aircraft and type of rescue and firefighting equipment in use at the aerodrome, including pressure-fed fuel fires.[2]

Airport firefighters specialise in dealing with complex fires and rescues from aircraft. A great deal of their daily routine is spent training and drilling for such eventualities.

Unlike their local authority counterparts, airport firefighters have to re-qualify every four years to be deemed competent.

There are a number of reasons for this:

References[edit]


Retrieved from "https://en.wikipedia.org/w/index.php?title=Airport_rescue_and_firefighting_services_in_the_United_Kingdom&oldid=1225348583"

Categories: 
Fire and rescue services of the United Kingdom
Aircraft rescue and firefighting
Hidden categories: 
All articles with dead external links
Articles with dead external links from March 2023
Articles with permanently dead external links
Use dmy dates from April 2022
Articles needing additional references from April 2008
All articles needing additional references
All articles with specifically marked weasel-worded phrases
Articles with specifically marked weasel-worded phrases from July 2019
 



This page was last edited on 23 May 2024, at 21:25 (UTC).

Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



Privacy policy

About Wikipedia

Disclaimers

Contact Wikipedia

Code of Conduct

Developers

Statistics

Cookie statement

Mobile view



Wikimedia Foundation
Powered by MediaWiki