Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Background  





2 Sterilization methods in use  





3 Sterile processing technician  





4 Divisions  



4.1  Decontamination  





4.2  Sterilization and storage  





4.3  Distribution  







5 See also  





6 References  














Central sterile services department






Deutsch
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Sterile dental instruments from hospital central supply (barcoded label indicating sterilization date, expiry date and contents).

The central sterile services department (CSSD), also called sterile processing department (SPD), sterile processing, central supply department (CSD), or central supply, is an integrated place in hospitals and other health care facilities that performs sterilization and other actions on medical devices, equipment and consumables; for subsequent use by health workers in the operating theatre of the hospital and also for other aseptic procedures, e.g. catheterization, wound stitching and bandaging in a medical, surgical, maternityorpaediatric ward.[1]

Background

[edit]

The operations of a sterile services department usually consist of the cleaning, disinfection, and sterilization of reusable medical equipment. Reusable medical equipment, or RME, can consist of any medical equipment from stainless steel surgical instrumentation, to IV pumps and crash carts. RME is separated into three classes: non-critical, semi-critical, and critical, with each class requiring a minimum level of reprocessing.[2]

Non-critical items, such as IV poles and pumps, require a minimum of intermediate level disinfection which can be accomplished with most hospital disinfectants.[2]

Semi-critical items are items that are expected to have contact with what an intact mucous membrane, and normally consists of endoscopes like those used in colonoscopies. These items require high level disinfectants such as glutaraldehyde solution, peracetic acid, or hydrogen peroxide plasma.[2]

Critical items, which include any instrument which will be introduced into a patient blood stream or in a normally sterile area of the body, require sterilization.[2]

Sterilization methods in use

[edit]

Sterilization is the process of destroying all living organisms on an item and is the main task of most sterile services departments. Items to be sterilized must first be cleaned in a separate decontamination room and inspected for effectiveness, cleanliness and damage. There are multiple methods of sterilization, and which one is used is dependent on many factors including: operational cost, potential hazards to workers, efficacy, time, and composition of the materials being sterilized.[citation needed]

In the US, one of the cheapest and easiest methods is steam sterilization, where instrumentation trays and packages are placed in a chamber which is them filled with 250–270 °F (121–132 °C) steam, killing all microorganisms.[3]

Sterilization can also be achieved using ethylene oxide (ETO) gas. This process was created in the 1950s by the US military[4] and is used on items that cannot withstand the high temperatures of steam sterilization. ETO sterilization takes far longer than steam sterilization and is hazardous to workers, so alternative methods were created in the 1990s. The most common method for sterilizing at low temperatures today is by using hydrogen peroxide plasma, which has near zero risk to workers and cycles take a fraction of the time of ETO sterilization.[citation needed]

Depending on the healthcare facility's policy, there will be either an event related or time related sterile storage policy. If the policy is time related, an expiration date is placed on the sterile package, before being supplied to the end-user as a sterile product. If along the supply route, the sealed package got damaged or opened by a health worker, it needs to be returned to the CSSD for re-sterilization. If the healthcare facility's policy is event related, the package is considered sterile until an event occurs to compromise its sterility (e.g. opened, dropped package, high humidity conditions, etc.)[citation needed]

Decontamination is the most important step in the sterilization process beginning with point of use cleaning in the operating room. Items must be cleaned according to the manufacturer's instructions for use (IFU's). These must be followed for each item processed. Failure to properly clean a device will prevent sterilization from occurring. There are several factors that contribute to having a properly functioning decontamination area: [1] there must be proper dilution of detergents or damage to instruments will occur to include rusting and discoloration, [2] lumens are a big issue so there must be an assortment of brushes with varying lengths and diameters to thoroughly clean inside lumened instruments, [3] SPD staff need to be competent in the use of all processing equipment, [4] monthly in-service should be recurring and completed by the manufacturer's representative, [5] efficacy testing of the equipment should be completed and documented ensuring equipment is functioning as intended.[5]

Sterile processing technician

[edit]

A sterile processing technician is someone who cleans and sterilizes used surgical instruments and other medical supplies so that they can be safely redistributed and reused on future patients. This work is usually centralized in a special department of the medical facility. Job titles include the following:[citation needed]

Divisions

[edit]

Sterile processing departments are typically divided into four major areas to accomplish the functions of decontamination, assembly and sterile processing, sterile storage, and distribution.[6][7]

Decontamination

[edit]

Sterilization and storage

[edit]

Distribution

[edit]

See also

[edit]

References

[edit]
  1. ^ "Sterilization basics". University of Rochester. Retrieved 16 June 2016.
  • ^ a b c d Health, Center for Devices and Radiological. "Reprocessing of Reusable Medical Devices - What are Reusable Medical Devices?". www.fda.gov. Retrieved 2018-10-17.
  • ^ Rutala, W. A.; Stiegel, M. M.; Sarubbi, F. A. (1982-06-01). "Decontamination of laboratory microbiological waste by steam sterilization". Appl. Environ. Microbiol. 43 (6): 1311–1316. doi:10.1128/aem.43.6.1311-1316.1982. ISSN 0099-2240. PMC 244233. PMID 7103486.
  • ^ Reichert, Marimargaret; Young, Jack H. (1997). Sterilization Technology for the Health Care Facility. Jones & Bartlett Learning. ISBN 9780834208384.
  • ^ "Safety in the Operating Room Begins with Sterile Processing". 14 August 2018. Retrieved 2019-01-17.
  • ^ "Central sterile service department (CSSD) - Definition, Aim, Function and Activities, Advantages, Objectives and Functions, Planning, Basic Division, Equipment". BrainKart. Retrieved 2022-03-27.
  • ^ "Examining Central Sterile Services Department's role in patient safety". Omnia Health Insights. 2019-12-11. Retrieved 2022-03-27.

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Central_sterile_services_department&oldid=1226898320"

    Categories: 
    Hospital departments
    Medical hygiene organizations
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
    All articles with unsourced statements
    Articles with unsourced statements from September 2023
     



    This page was last edited on 2 June 2024, at 13:14 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki