Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  



























Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Measurement  





2 Factors affecting CVP  





3 See also  





4 References  





5 External links  














Central venous pressure






العربية
Català
Deutsch
Español
فارسی

Italiano
Nederlands

Norsk bokmål
Polski
Português
Русский
Српски / srpski
Svenska
ி
Українська

 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 




In other projects  



Wikimedia Commons
 


















From Wikipedia, the free encyclopedia
 


Central venous pressure (CVP) is the blood pressure in the venae cavae, near the right atrium of the heart. CVP reflects the amount of blood returning to the heart and the ability of the heart to pump the blood back into the arterial system. CVP is often a good approximation of right atrial pressure (RAP),[1] although the two terms are not identical, as a pressure differential can sometimes exist between the venae cavae and the right atrium. CVP and RAP can differ when arterial tone is altered. This can be graphically depicted as changes in the slope of the venous return plotted against right atrial pressure (where central venous pressure increases, but right atrial pressure stays the same; VR = CVP − RAP).

CVP has been, and often still is, used as a surrogate for preload, and changes in CVP in response to infusions of intravenous fluid have been used to predict volume-responsiveness (i.e. whether more fluid will improve cardiac output). However, there is increasing evidence that CVP, whether as an absolute value or in terms of changes in response to fluid, does not correlate with ventricular volume (i.e. preload) or volume-responsiveness, and so should not be used to guide intravenous fluid therapy.[2][3] Nevertheless, CVP monitoring is a useful tool to guide hemodynamic therapy. The cardiopulmonary baroreflex responds to an increase in CVP by decreasing systemic vascular resistance while increasing heart rate and ventricular contractility in dogs.[4]

Measurement[edit]

Site Normal
pressure range
(inmmHg)[5]
Central venous pressure 3–8
Right ventricular pressure systolic 15–30
diastolic 3–8
Pulmonary artery pressure systolic 15–30
diastolic 4–12
Pulmonary vein/

Pulmonary capillary wedge pressure

2–15
Left ventricular pressure systolic 100–140
diastolic 3–12

Normal CVP in patients can be measured from two points of reference:[citation needed]

CVP can be measured by connecting the patient's central venous catheter to a special infusion set which is connected to a small diameter water column. If the water column is calibrated properly the height of the column indicates the CVP.[citation needed]

In most intensive care units, facilities are available to measure CVP continuously.[citation needed]

Normal values vary between 4 and 12 cm H2O.

Factors affecting CVP[edit]

Factors that increase CVP include:[citation needed]

Factors that decrease CVP include:

See also[edit]

References[edit]

  1. ^ "Central Venous Catheter Physiology". Archived from the original on 2008-08-21. Retrieved 2009-02-27.
  • ^ Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, et al. (2004). "Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects" (PDF). Crit Care Med. 32 (3): 691–699. doi:10.1097/01.ccm.0000114996.68110.c9. PMID 15090949. S2CID 41905070.
  • ^ Marik P, Baram M, Vahid B (July 2008). "Does Central Venous Pressure Predict Fluid Responsiveness?" (PDF). Chest. 134 (1): 1351–1352. doi:10.1378/chest.08-1846. PMID 19059974. Archived from the original (PDF) on 2014-06-11. Retrieved 2012-12-09.
  • ^ Sala-Mercado JA, Moslehpour M, Hammond RL, Ichinose M, Chen X, Evan S, O'Leary DS, Mukkamala R (June 2014). "Stimulation of the Cardiopulmonary Baroreflex Enhances Ventricular Contractility in Awake Dogs: A Mathematical Analysis Study". American Journal of Physiology. Regulatory, Integrative and Comparative Physiology. 307 (4): R455–R464. doi:10.1152/ajpregu.00510.2013. PMC 4137157. PMID 24944253.
  • ^ Table 30-1 in: Goers TA, Klingensmith ME, Chen LE, Glasgow SC (2008). The Washington Manual of Surgery. Philadelphia: Wolters Kluwer Health/Lippincott Williams & Wilkins. ISBN 978-0-7817-7447-5.
  • External links[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Central_venous_pressure&oldid=1146724283"

    Categories: 
    Medical terminology
    Medical monitoring
    Cardiovascular physiology
    Hidden categories: 
    Articles with short description
    Short description is different from Wikidata
    All articles with unsourced statements
    Articles with unsourced statements from March 2021
    Articles with GND identifiers
     



    This page was last edited on 26 March 2023, at 15:58 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki