Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Coagulase test  



1.1  Slide test  





1.2  Tube test  







2 References  





3 External links  














Coagulase






العربية
Español
فارسی
Français

עברית
Nederlands

Polski
Português
Svenska
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


S. aureus uses coagulase to form a fibrin coat from fibrinogen present in the bloodstream. This helps the bacteria evade detection and phagocytosis by the immune system.

Coagulase is a protein enzyme produced by several microorganisms that enables the conversion of fibrinogentofibrin. In the laboratory, it is used to distinguish between different types of Staphylococcus isolates. Importantly, S. aureus is generally coagulase-positive, meaning that a positive coagulase test would indicate the presence of S. aureus or any of the other 11 coagulase-positive Staphylococci.[1] A negative coagulase test would instead show the presence of coagulase-negative organisms such as S. epidermidisorS. saprophyticus. However, it is now known that not all S. aureus are coagulase-positive.[2][3] Whereas coagulase-positive Staphylococci are usually pathogenic, coagulase-negative Staphylococci are more often associated with opportunistic infection.[4]

It is also produced by Yersinia pestis.[5]

Coagulase reacts with prothrombin in the blood. The resulting complex is called staphylothrombin, which enables the enzyme to act as a protease to convert fibrinogen, a plasma protein produced by the liver, to fibrin. This results in clotting of the blood. Coagulase is tightly bound to the surface of the bacterium S. aureus and can coat its surface with fibrin upon contact with blood. The fibrin clot may protect the bacterium from phagocytosis and isolate it from other defenses of the host.[6] The fibrin coat can therefore make the bacteria more virulent. Bound coagulase is part of the larger family of MSCRAMM adhesin proteins.

Coagulase test[edit]

The coagulase test has traditionally been used to differentiate Staphylococcus aureus from coagulase-negative staphylococci. S.aureus produces two forms of coagulase (i.e., bound coagulase and free coagulase). Bound coagulase, otherwise known as "clumping factor", can be detected by carrying out a slide coagulase test, and free coagulase can be detected using a tube coagulase test.

Slide test[edit]

A slide coagulase test is run with a negative control to rule out autoagglutination. Two drops of saline are put onto the slide labeled with sample number, Test (T) and control (C). The two saline drops are emulsified with the test organism using a wire loop, straight wire, or wooden stick. A drop of plasma (rabbit plasma anticoagulated with EDTA is recommended)[7] is placed on the inoculated saline drop corresponding to test, and mixed well, then the slide is rocked gently for about 10 seconds.

If the slide coagulase test is negative, a tube test should follow as a confirmation. Clumping in both drops is an indication of autoagglutination, so a tube test should be carried out. Tube test is not performed each institutions but most of the result depends on blood cultures from lab.

Tube test[edit]

A fibrin clot formed in a test tube by the coagulase reaction

The tube test uses rabbit plasma that has been inoculated with a staphylococcal colony (i.e., Gram-positive cocci which are catalase positive). The tube is then incubated at 37 °C for 1.5 hours. If negative, then incubation is continued up to 18 hours.

References[edit]

  1. ^ Becker et al., 2014. PMID 25278577
  • ^ Ryan KJ, Ray CG (editors) (2004). Sherris Medical Microbiology (4th ed.). McGraw Hill. ISBN 0-8385-8529-9.
  • ^ PreTest, Surgery, 12th ed., p.88
  • ^ González-Martín M, Suárez-Bonnet A, Tejedor-Junco MT (2020). "Virulence factors in coagulase-positive staphylococci of veterinary interest other than Staphylococcus aureus". Veterinary Quarterly. 40 (1): 118–131. doi:10.1080/01652176.2020.1748253. PMC 7178840. PMID 32223696.
  • ^ "coagulase"atDorland's Medical Dictionary
  • ^ Tortora, Gerard J.; Funke, Berdell R.; Case, Christine L. (2013). Microbiology: An Introduction (11 ed.). Glenview, IL: Pearson Education Inc. p. 434. ISBN 978-0-321-73360-3.
  • ^ A.Forbes, Betty; Daniel F.Sahm; Alice S.Weissfeld (1998). BAILEY& SCOTT'S Diagnostic Microbiology (Tenth ed.). Don Ladig. pp. 430–431. ISBN 0-8151-2535-6.
  • ^ "coagulase test"atDorland's Medical Dictionary
  • External links[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Coagulase&oldid=1231847571"

    Categories: 
    Microbiology
    EC 3.4.23
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
    Webarchive template wayback links
     



    This page was last edited on 30 June 2024, at 15:56 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki