Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Implementation  





2 See also  





3 References  














Delayed extraction






Italiano
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Delayed extraction with laser desorption ionization. Top: the laser fires at t=0 forming a fast "red" ion and slow "blue" ion of the same m/z, Middle: the red ion takes the lead since it has a greater velocity (and kinetic energy) but since it is farther from the acceleration plate at voltage +V, it gains less energy than the blue ion. Bottom: The blue ion has gained sufficient energy such that it arrives at the detector at the same time as the red ion.

Delayed extraction is a method used with a time-of-flight mass spectrometer in which the accelerating voltage is applied after some short time delay following pulsed laser desorption/ionization from a flat surface of target plate or, in other implementation, pulsed electron ionizationorResonance enhanced multiphoton ionization in some narrow space between two plates of the ion extraction system. The extraction delay can produce time-of-flight compensation for ion energy spread and improve mass resolution.

Implementation

[edit]

Resolution can be improved in time-of-flight mass spectrometer with ions produced at high vacuum conditions (better than few microTorr) by allowing the initial packet ions to spread in space due to their translational energy before being accelerated into the flight tube. With ions produced by electron ionization or laser ionization of atoms or molecules from a rarefied gas, this is referred to as "time-lag focusing".[1] With ions produced by laser desorption/ionization[2]orMALDI[3][4] from a conductive surface of target plate, this is referred as "delayed extraction."

With delayed extraction, the mass resolution is improved due to the correlation between velocity and position of the ions after those have been produced in the ion source. Ions produced with greater kinetic energy have a higher velocity and during the delay time move closer to the extraction electrode before the accelerating voltage is applied across the target or pulsed electrode. The slower ions with less kinetic energy stay closer to a surface of the target electrode or pulsed electrode when the accelerating voltage is applied and therefore start being accelerated at a greater potential compared to the ions farther from the target electrode. With the proper delay time, the slower ions will receive enough extra potential energy to catch the faster ions after flying some distance from the pulsed acceleration system. Ions of the same mass-to-charge ratio will then drift through the flight tube to the detector in the same time.

See also

[edit]

References

[edit]
  1. ^ Wiley, W. C.; McLaren, I. H. (1955), "Time-of-Flight Mass Spectrometer with Improved Resolution", Review of Scientific Instruments, 26 (12): 1150, Bibcode:1955RScI...26.1150W, doi:10.1063/1.1715212
  • ^ V. S. Antonov, V. S. Letokhov, and A. N. Shibanov, (1980) Formation of molecular ions as a result of irradiation of the surface of molecular crystals Archived 2015-06-10 at the Wayback Machine, Pis'ma Zh. Eksp. Teor. Fiz., 31, 471; JETP Lett., 31, 441.
  • ^ Brown RS, Lennon JJ (July 1995), "Mass resolution improvement by incorporation of pulsed ion extraction in a matrix-assisted laser desorption/ionization linear time-of-flight mass spectrometer", Anal. Chem., 67 (13): 1998–2003, doi:10.1021/ac00109a015, PMID 8694246.
  • ^ Colby, Steven M.; King, Timothy B.; Reilly, James P.; Lubman, D. M. (1994), "Improving the resolution of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry by exploiting the correlation between ion position and velocity", Rapid Communications in Mass Spectrometry, 8 (11): 865, Bibcode:1994RCMS....8..865C, doi:10.1002/rcm.1290081102

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Delayed_extraction&oldid=1198717674"

    Category: 
    Mass spectrometry
    Hidden category: 
    Webarchive template wayback links
     



    This page was last edited on 24 January 2024, at 22:09 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki