Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Protocol internals  



1.1  Additional CRC  







2 Cables  





3 Usage  





4 Devices  





5 References  














FICON






Deutsch
Español
Français

Русский
Українська
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Fibre Channel
Layer 4. Protocol mapping
LUN masking
Layer 3. Common services
Layer 2. Network
Fibre Channel fabric
Fibre Channel zoning
Registered state change notification
Layer 1. Data link
Fibre Channel 8b/10b encoding
Layer 0. Physical

FICON (Fibre Connection) is the IBM proprietary name for the ANSI FC-SB-3 Single-Byte Command Code Sets-3 Mapping Protocol for Fibre Channel (FC) protocol. It is a FC layer 4 protocol used to map both IBM's antecedent (either ESCON or parallel Bus and Tag) channel-to-control-unit cabling infrastructure and protocol onto standard FC services and infrastructure. The topology is fabric utilizing FC switches or directors. Valid rates include 1, 2, 4, 8, 16,[1] and 32 Gigabit per second data rates at distances up to 100 km.

FICON was introduced in 1998 as part of System/390 G5 IBM mainframe.[2] In July 2013, FICON replaced ESCON in new zEnterprise BC12/EC12, and later models,[3] [4] because of FICON's technical superiority (especially its higher performance) and lower cost.

Protocol internals[edit]

Each FICON channel port is capable of multiple concurrent data exchanges (a maximum of 32) in full duplex mode. Information for active exchanges is transferred in Fibre Channel sequences mapped as FICON Information Units (IUs) which consist of one to four Fibre Channel frames, only the first of which carries 32 bytes of FICON (FC-SB-3) mapping protocol. Each FICON exchange may transfer one or many such IUs.

FICON channels use five classes of IUs to conduct information transfers between a channel and a control unit. They are: Data, Command, Status, Control, and lastly Link Control. Only a channel port may send Command or Command and Data IUs, while only a control unit port may send Status IUs.

As with prior IBM mainframe channel protocols, there is a concept of a channel to control unit "connection". In its most primitive form, a connection is associated with a single channel program. In practice, a single channel program may result in the establishment of several sequential connections. This normally occurs during periods where data transfers become dormant while waiting for some type of independent device activity to complete (such as the physical positioning of tape or a disk access arm). In such cases, the connection may be closed by action of the device's control unit with the signaling of appropriate status. When the control unit is ready to resume such an interrupted connection, it signals the channel to reconnect and resume the interrupted channel program. By closing temporarily dormant connections, channel and control unit facilities may be better utilized to serve other active channel programs and certain protocol timeouts that might otherwise occur may be avoided.

FICON uses two Fibre Channel exchanges for a channel – control unit connection – one for each direction. So while a Fibre Channel exchange is capable of carrying a command and response on a single exchange, and all other FC-4 protocols work that way, the response to a FICON IU is always on a different exchange from the IU to which it is a response. The two exchanges that implement a connection are called an exchange pair (Note that the concept of the two exchanges being related exists only at the FC-4 layer). While other FC-4s have a single "data structure type" code that characterizes their IUs in Fibre Channel frame headers, FICON has two. One is for IUs from channel to control unit; the other for control unit to channel.

Except for some initialization dialogue that requires stronger synchronization, FICON uses Fibre Channel class of service 3 (Datagram). Thus, at the Fibre Channel physical (FC-2 and below) level, the communication is connectionless, frames and sequences may arrive out of order, and there is no acknowledgement of arrival. But all of that exists at the FC-4 level.

Additional CRC[edit]

The integrity of customer data carried within one or more IUs is protected by a running 32-bit cyclic redundancy check (CRC) contained in the last frame of an IU classified as an ending IU within each data transfer. This is in addition to the standard Fibre Channel CRC used to verify the integrity of each individual FC frame. As such, the FICON CRC has the capability of detecting missing or out of sequence frames/IUs.

Cables[edit]

FICON may employ Fibre Channel fiber optic cables with either short wavelength (multi-mode; 62.5 or 50 micrometer core) or long wavelength (single mode; 9 micrometer core). Long wavelength is used in the majority of applications owing to its superior optical power budget and bandwidth. FICON cannot use Copper Fibre Channel cables.

Usage[edit]

FICON is used exclusively with computers based on the IBM z/Architecture (current descendant of System/360, System/370, etc.), commonly called mainframes. FICON and its predecessors are the only protocols sufficient to communicate with traditional mainframe peripheral devices, especially for z/OS. However, most[dubiousdiscuss] mainframe operating systems also support FCP (SCSI command set over Fibre Channel).

FICON is technically quite similar to more popular storage protocols, such as FCP. Both FICON and FCP share levels 1–3 of Fibre Channel specifications. Some administrators argue that FICON offers somewhat easier troubleshooting in mainframe environments, but the inherent technical advantages and disadvantages between FICON and FCP are much alike. Some mainframe-specific setups, such as GDPS, require FICON (or its predecessor ESCON). Mainframe-attached storage, such as IBM's System Storage DS8000, often supports both protocols. The storage is divided into fixed block storage volumes (accessed with FCP) and mainframe-specific CKD/ECKD storage volumes (accessed with FICON and/or ESCON).

Devices[edit]

Disk storage products that can be attached via FICON include:

Tape storage facilities include:

Hardware Security Module (HSM) products that support FICON include:

Switches/directors that support FICON include:

Managed File Transfer products that support FICON include:

Other older FICON switching platforms are still in use.[when?] These include the McDATA 6064, CNT UMD, and CNT (Inrange) FC/9000. Inrange was acquired by CNT in 2003, CNT was acquired by McDATA in 2005, and in 2007 McDATA was in turn acquired by Brocade Communications Systems. Approximately 80% of FICON directors and switches installed in mainframe environments were Brocade products at the time. McDATA was well established in the mainframe directors space, manufacturing the 9032-3 and 9032-5 ESCON directors for IBM, as well as the FICON Bridge Card.[6] Brocade has many co-patents with IBM for FICON and ESCON technology. Cisco Systems was a relative newcomer to this space, with their first FICON director coming out in 2003.

Other manufacturers producing FICON-compatible equipment include Optica Technologies, and InfoPrint Solutions Company, which offers high-volume printers that can attach via FICON.

References[edit]

  1. ^ "Faster data access with FICON Express8 for System z10".
  • ^ New IBM S/390 Parallel Enterprise Servers -- Generation 5 Models, Announcement Letter: 198-115. IBM. May 7, 1998.
  • ^ IBM zEnterprise BC12 (zBC12) extends modern mainframe capabilities for enterprises of all sizes to help cut costs, improve service, and fuel innovation for business growth. IBM US Announcement Letter 113-121. July 23, 2013.
  • ^ IBM zEnterprise 114 - Freedom by design. IBM US Announcement Letter 111-136. IBM. July 12, 2011.
  • ^ "Payment Security Systems: payShield 9000". Thales Group. Archived from the original on 2013-11-13.
  • ^ Steve Guendert. "A Comprehensive Guide for Migrating from ESCON to FICON"

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=FICON&oldid=1223611700"

    Categories: 
    Fibre Channel
    IBM System/360 mainframe line
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
    Articles needing additional references from December 2014
    All articles needing additional references
    All accuracy disputes
    Articles with disputed statements from July 2010
    All articles with vague or ambiguous time
    Vague or ambiguous time from August 2011
     



    This page was last edited on 13 May 2024, at 07:37 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki