(Top)
 


1 Types  





2 Valves  





3 Physics  





4 See also  





5 References  



5.1  Sources  







6 External links  














Floodgate






العربية
Català
Čeština
Cymraeg
Deutsch
Español
Euskara
فارسی
Français
Galego
Հայերեն
Hrvatski
Bahasa Indonesia
Italiano

Қазақша

Português
Română
Русский
Srpskohrvatski / српскохрватски

Türkçe
Українська
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 




In other projects  



Wikimedia Commons
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Tokyo floodgates created to protect from typhoon surges

Floodgates, also called stop gates, are adjustable gates used to control water flow in flood barriers, reservoir, river, stream, or levee systems. They may be designed to set spillway crest heights in dams, to adjust flow rates in sluices and canals, or they may be designed to stop water flow entirely as part of a levee or storm surge system. Since most of these devices operate by controlling the water surface elevation being stored or routed, they are also known as crest gates. In the case of flood bypass systems, floodgates sometimes are also used to lower the water levels in a main river or canal channels by allowing more water to flow into a flood bypass or detention basin when the main river or canal is approaching a flood stage.

Types[edit]

Bulkhead gates are vertical walls with movable, or re-movable, sections. Movable sections can be lifted to allow water to pass underneath (as in a sluice gate) and over the top of the structure. Historically, these gates used stacked timbers known as stoplogs or wooden panels known as flashboards to set the dam's crest height. Some floodgates known as coupures in large levee systems slide sideways to open for various traffic. Bulkhead gates can also be made of other materials and used as a single bulkhead unit. Miter gates are used in ship locks and usually close at an 18° angle to approximate an arch.
A sluice gate on the Harran canal
Aflood wall gate at Harlan, Kentucky
Hinged crest gates, are wall sections that rotate from vertical to horizontal, thereby varying the height of the dam. They are generally controlled with hydraulic power, although some are passive and are powered by the water being impounded. Variations:
  • flap gate
  • fish-belly flap gates
  • Bascule gates
  • Pelican gates
AUS Army Corps of Engineers hinged bascule crest gate during installation
Fish belly flap gates at the Scrivener Dam, Canberra
Radial gates are rotary gates consisting of cylindrical sections. They may rotate vertically or horizontally. Tainter gates are a vertical design that rotates up to allow water to pass underneath. Low friction trunnion bearings, along with a face shape that balances hydrostatic forces, allow this design to close under its own weight as a safety feature.
Tainter gate diagram
Tainter gates and spillway
Drum gates are hollow gate sections that float on water. They are pinned to rotate up or down. Water is allowed into or out of the flotation chamber to adjust the dam's crest height.
Drum gates are controlled with valves.
Drum gates on a diversion dam
  • Roller gates are large cylinders that move in an angled slot. They are hoisted with a chain and have a cogged design that interfaces with their slot.
  • Clamshell gates have an external clamshell leaf design.
A roller gate on the Mississippi.
Clamshell floodgates at the Arrowrock Dam.
Fusegates are a mechanism designed to provide the controlled release of water in the event of exceptionally large floods. The design consists of free standing blocks (the fusegates) set side by side on a flattened spillway sill. The Fusegate blocks act as a fixed weir most of the time, but in excessive flood conditions they are designed to topple forward, allowing the controlled discharge of water. Multiple fusegates are generally set up side by side, with each fusegate designed to release under progressively extreme flooding, thus minimizing the impact of the floodwater on the river downstream.[1] The System was invented and patented by François Lempérière[2] for Hydroplus (Paris, France), subsidiary of GTM Entrepose. It has been installed on more than 50 dams around the world with sizes ranging from 1 m to more than 9 m in height. Fusegate are typically used to increase the storage capacity of existing dams or to maximize the discharge potential of undersized spillways.
Typical fusegate sketch
Fusegate in Terminus Dam - Lake Kaweah
Mitre gates

Valves[edit]

[clarification needed]

Discharge from a Howell-Bunger valve

Valves used in floodgate applications have a variety of design requirements and are usually located at the base of dams. Often, the most important requirement (besides regulating flow) is energy dissipation. Since water is very heavy, it exits the base of a dam with the enormous force of water pushing from above. Unless this energy is dissipated, the flow can erode nearby rock and soil and damage structures.

Other design requirements include taking into account pressure head operation, the flow rate, whether the valve operates above or below water, and the regulation of precision and cost.[citation needed]

Physics[edit]

Opened floodgates at the Merikoski Power PlantinOulu, Finland

The force on a rectangular flood gate can be calculated by the following equation:

where:

F = force measured in newtons (N)
p = pressure measured in pascal (Pa)
where:
A = area = rectangle: length × height measured in m2
where:
length = the horizontal length of a rectangular floodgate measured in metres
height = the height of a non-submerged flood gate from the bottom of the water column to the water surface measured in metres

If the rectangular flood gate is submerged below the surface the same equation can be used but only the height from the water surface to the middle of the gate must be used to calculate the force on the flood gate.

See also[edit]

References[edit]

  1. ^ "Fusegate Operation". www.Hydroplus.com. Archived from the original on 2013-10-23. Retrieved 2013-11-21.
  • ^ "Patents by Inventor Francois Lemperiere". Justia Patents.
  • Sources[edit]

    External links[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Floodgate&oldid=1221784453"

    Categories: 
    Dams
    Hydrology
    Water transport infrastructure
    Flood barriers
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
    Wikipedia articles needing clarification from March 2008
    All articles with unsourced statements
    Articles with unsourced statements from March 2008
    Commons link is on Wikidata
     



    This page was last edited on 1 May 2024, at 23:44 (UTC).