Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 History  





2 Technologies  



2.1  Electrical  





2.2  Optical  





2.3  Fitness metrics  







3 Accuracy  





4 See also  





5 References  





6 External links  














Heart rate monitor






العربية
Català
Dansk
Deutsch
Eesti
Español
Euskara
فارسی
Français

Italiano
Қазақша
Latviešu
Magyar
Nederlands

Norsk bokmål
Polski
Русский

Suomi
ி
Українська


 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 




In other projects  



Wikimedia Commons
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Smartwatch displaying a reading of 92 beats per minute

Aheart rate monitor (HRM) is a personal monitoring device that allows one to measure/display heart rate in real time or record the heart rate for later study. It is largely used to gather heart rate data while performing various types of physical exercise. Measuring electrical heart information is referred to as electrocardiography (ECG or EKG).

Medical heart rate monitoring used in hospitals is usually wired and usually multiple sensors are used. Portable medical units are referred to as a Holter monitor. Consumer heart rate monitors are designed for everyday use and do not use wires to connect.

History

[edit]

Early models consisted of a monitoring box with a set of electrode leads which attached to the chest. The first wireless EKG heart rate monitor was invented in 1977 by Polar Electro as a training aid for the Finnish National Cross Country Ski team. As "intensity training" became a popular concept in athletic circles in the mid-80s, retail sales of wireless personal heart monitors started in 1983.[1]

Technologies

[edit]
X-ray image of a chest strap (left: frontal view; right: side view). Visible is the circuit board, the antenna for data transfer, the battery and the connections to the electrodes in the adjoining belt at picture top and bottom.

Modern heart rate monitors commonly use one of two different methods to record heart signals (electrical and optical). Both types of signals can provide the same basic heart rate data, using fully automated algorithms to measure heart rate, such as the Pan-Tompkins algorithm.[2]

ECG (Electrocardiography) sensors measure the bio-potential generated by electrical signals that control the expansion and contraction of heart chambers, typically implemented in medical devices.

PPG (Photoplethysmography) sensors use a light-based technology to measure the blood volume controlled by the heart's pumping action.

Electrical

[edit]

The electrical monitors consist of two elements: a monitor/transmitter, which is worn on a chest strap, and a receiver. When a heartbeat is detected, a radio signal is transmitted, which the receiver uses to display/determine the current heart rate. This signal can be a simple radio pulse or a unique coded signal from the chest strap (such as Bluetooth, ANT, or other low-power radio links). Newer technology prevents one user's receiver from using signals from other nearby transmitters (known as cross-talk interference) or eavesdropping. Note, the older Polar 5.1 kHz radio transmission technology is usable underwater. Both Bluetooth and Ant+ use the 2.4 GHz radio band, which cannot send signals underwater.

Optical

[edit]
Welsh Government video: a smart phone heart rate monitor, 2016

More recent devices use optics to measure heart rate by shining light from an LED through the skin and measuring how it scatters off blood vessels. In addition to measuring the heart rate, some devices using this technology are able to measure blood oxygen saturation (SpO2). Some recent optical sensors can also transmit data as mentioned above.

Newer devices such as cell phones or watches can be used to display and/or collect the information. Some devices can simultaneously monitor heart rate, oxygen saturation, and other parameters. These may include sensors such as accelerometers, gyroscopes, and GPS to detect speed, location and distance.[3] In recent years, it has been common for smartwatches to include heart rate monitors, which has greatly increased popularity.[4] Some smartwatches, smart bands and cell phones often use PPG sensors.[5]

Fitness metrics

[edit]

Garmin (Venu Sq 2 and Lily*), Polar Electro (Polar H9, Polar H10, and Polar Verity Sense),[6] Suunto, Samsung Galaxy Watch (Galaxy Watch 5 and Galaxy Watch 6*), Google (Pixel Watch 2*), Spade and Company, Vital Fitness Tracker**, Apple Watch (Series 7**, Series 9*, Apple Watch SE*, Apple Watch Ultra 2*), Mobvoi (TicWatch Pro 5*) and Fitbit (Versa 3** and Versa 4*) are vendors selling consumer heart rate products. Most companies use their own proprietary heart rate algorithms.[7][8]

Accuracy

[edit]

The newer, wrist based heart rate monitors have achieved almost identical levels of accuracy as their chest strap counterparts with independent tests showing up to 95% accuracy, but sometimes more than 30% error can persist for several minutes.[9] Optical devices can be less accurate when used during vigorous activity,[10] or when used underwater.

Currently, heart rate variability is less available on optical devices.[11] Apple introduced HRV data collection to the Apple Watch devices in 2018.[12] Fitbit started offering HRV monitoring on their devices starting from the Fitbit Sense, released in 2020.[13]

See also

[edit]

References

[edit]
  1. ^ Burke E, ed. (1998). Precision Heart Rate Training. Champaign, IL: Human Kinetics. ISBN 978-0-88011-770-8.
  • ^ Pan J, Tompkins WJ (March 1985). "A real-time QRS detection algorithm". IEEE Transactions on Bio-Medical Engineering. 32 (3): 230–236. doi:10.1109/TBME.1985.325532. PMID 3997178. S2CID 14260358.
  • ^ Lloret J, Sendra S, Ardid M, Rodrigues JJ (2012). "Underwater wireless sensor communications in the 2.4 GHz ISM frequency band". Sensors. 12 (4): 4237–4264. Bibcode:2012Senso..12.4237L. doi:10.3390/s120404237. PMC 3355409. PMID 22666029.
  • ^ Saygin D, Tabib T, Bittar HE, Valenzi E, Sembrat J, Chan SY, et al. (2020). "Transcriptional profiling of lung cell populations in idiopathic pulmonary arterial hypertension". Pulmonary Circulation. 10 (1). doi:10.1109/ISBB.2015.7344944. PMC 7052475. PMID 32166015. S2CID 10254964.
  • ^ Song, Victoria (1 April 2022). "How to measure heart rate on your smartwatch / Smartwatches have beefed up their heart health features in recent years". The Verge. Retrieved 27 February 2024.
  • ^ Sawh, Michael (4 June 2021). "Polar Verity Sense review". techradar.com. Retrieved 27 February 2024.
  • ^ Colon, Alex; Moscaritolo, Angela (20 December 2023). "The Best Smartwatches for 2024 (*Note: PC Magazine top 10 pick for 2024)". pcmag.com. Retrieved 27 February 2024.
  • ^ "The Top Three Smartwatches Ranked (**Note: smart watch review top 3 pick for 2022)". smartwatchreview.org. 20 December 2023. Retrieved 27 February 2024.
  • ^ Haskins T (23 April 2022). "Chest Strap Vs Wrist Based HR Accuracy". CardioCritic.com.
  • ^ "ECG vs PPG for Heart Rate Monitoring: Which is Best?". neurosky.com. 28 January 2015. Retrieved 2018-11-28.
  • ^ Barnhart P (21 March 2022). "Are Wrist Type Monitors Reliable?". All The Stuff.
  • ^ Caldwell S (26 March 2018). "Heart Rate Variability (HRV): What is it, and why does Apple track it?". iMore. Retrieved 2022-01-24.
  • ^ "A timeline and history of Fitbit". verizon.com. Retrieved 2024-05-13.
  • [edit]
    Retrieved from "https://en.wikipedia.org/w/index.php?title=Heart_rate_monitor&oldid=1223667548"

    Categories: 
    Biomedical engineering
    Diagnostic cardiology
    Exercise equipment
    Finnish inventions
    Medical monitoring equipment
    Physiological instruments
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
    Articles with hAudio microformats
    Commons link is locally defined
     



    This page was last edited on 13 May 2024, at 16:05 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki