Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Design and manufacture  





2 Installation  





3 Safety  





4 See also  





5 References  














I-joist






Deutsch
فارسی
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


I-joists
An I-joist
A partially constructed floor built with I-joists

An engineered wood joist, more commonly known as an I-joist, is a product designed to eliminate problems that occur with conventional wood joists. Invented in 1969, the I-joist is an engineered wood product that has great strength in relation to its size and weight. The biggest notable difference from dimensional lumber is that the I-joist carries heavy loads with less lumber than a dimensional solid wood joist.[1] As of 2005, approximately 50% of all wood light framed floors used I-joists.[2][clarification needed] I-joists were designed to help eliminate typical problems that come with using solid lumber as joists.

The advantage of I-joists is they are less likely to bow, crown, twist, cup, check, or split as would a piece of dimensional lumber. I-joists' dimensional soundness and little or no shrinkage help eliminate squeaky floors.

The disadvantage of I-joists is very rapid structural failure when directly exposed to fire (much like trusses), reducing the time available for residents to escape and increasing the danger to firefighters.

Design and manufacture[edit]

An I-joist has two main parts, the web and flange. The web is sandwiched between a top and bottom flange, creating the "I" shape. The flange can be made from laminated veneer lumber or solid wood finger-jointed together for ultimate strength. It is grooved on one side to receive the web. The web is typically made from plywood, laminated veneer lumber, or oriented strand board. After sizing the webs and flanges, they are assembled with water-resistant glue by pressing the web into the top and bottom flange. After assembly, the I-joist is end-trimmed and heat-cured or left at room temperature to reach approximately equilibrium moisture content. Sizes vary according to the I-joist's intended load and span. Depths can range from 9+14 to 24 inches (230–610 mm) and reach up to 80 feet (24 m) in length, although 40 to 42 feet (12–13 m) is more common. The intended use for an I-joist is for floor and roof joists, wall studs, and roof rafters in both residential and commercial construction.[1]

Installation[edit]

I-joist

I-joists require correct installation. The most common mistake is misplacing or improperly sizing holes in the web, which can compromise the joist's strength, potentially leading to structural failure.

Common mistakes made with installing I-joists include cutting or chiseling the flange, improperly sized joist hangers, improper nailing and wrong-sized nails. The rim joist depth must match the I-joist size. Mismatches can strain the joist.

A similar situation occurs where the I-joist crosses a main beam. Installing squash blocks (2×4 materials 116 in or 1.6 mm higher than the I-joist) alongside the I-joists transfers the load from the I-joist onto the beam. Missed nails and glue setting too fast can lead to an uneven or squeaky floor.[3]

Safety[edit]

The lightweight nature of I-joists makes them more vulnerable to fire than dimensional lumber.[4] A report by Underwriters Laboratories found that structural assemblies composed of I-joists fail significantly sooner under fire conditions than those composed of dimensional lumber.[5] Fire-induced failures of lightweight trusses and I-joists have led to the deaths of several firefighters.[6] In order to use i-joists in a fire-rated assembly, additional detailing is required to ensure building safety.[7]

See also[edit]

References[edit]

  1. ^ a b Vogt, Floyd. Carpentry. 4th ed. Clifton Park, NY: Thompson Delmar Learning, 2001
  • ^ Allen, Edward, and Joseph Iano. Fundamentals of Building Construction. Vol. 4th. Hoboken, NJ: John Wiley & Sons Inc, 2004
  • ^ Eck, Curtis. "Wood I-Joist Dos and Donts". Journal of Light Construction (Sept. 1995)
  • ^ "Structural Collapse Under Fire Conditions". May 2008.
  • ^ "Report on Structural Stability of Engineered Lumber in Fire Conditions" (PDF). Underwriters Laboratories. 30 September 2008. Archived from the original (PDF) on July 1, 2017.
  • ^ Earls, Alan (July 2009). "Lightweight Construction". National Fire Protection Association Journal. Retrieved November 6, 2020.
  • ^ "I-Joist Fire Assemblies - APA – The Engineered Wood Association". apawood.org. Retrieved 2022-10-07.
  • Lumber/
    timber

  • Beam
  • Bressummer
  • Cruck
  • Flitch beam
  • Flooring
  • Joist
  • Lath
  • Molding
  • Panelling
  • Plank
  • Plate
  • Post
  • Purlin
  • Rafter
  • Railroad ties
  • Reclaimed
  • Shingle
  • Siding
  • Sill
  • Stud
  • Timber truss
  • Treenail
  • Truss
  • Utility pole
  • Engineered
    wood

  • Glued laminated timber
  • I-joist
  • Fiberboard
  • Oriented strand board
  • Oriented structural straw board
  • Particle board
  • Plywood
  • Structural insulated panel
  • Wood–plastic composite
  • Fuelwood

  • Firelog
  • Firewood
  • Pellet fuel
  • Wood fuel
  • Fibers

  • Corrugated fiberboard
  • Paper
  • Paperboard
  • Pulp
  • Pulpwood
  • Rayon
  • Derivatives

  • Cellulose
  • Hemicellulose
  • Cellulosic ethanol
  • Dyes
  • Lignin
  • Liquid smoke
  • Lye
  • Methanol
  • Pyroligneous acid
  • Pine tar
  • Pitch
  • Sandalwood oil
  • Tannin
  • Wood gas
  • By-products

  • Black liquor
  • Ramial chipped wood
  • Sawdust
  • Tall oil
  • Wood flour
  • Wood wool
  • Woodchips
  • Historical

  • Bavin (wood)
  • Billet (wood)
  • Clapboard
  • Dugout canoe
  • Potash
  • Sawdust brandy
  • Split-rail fence
  • Tanbark
  • Timber framing
  • Wooden masts
  • See also

  • Certified wood
  • Destructive distillation
  • Dry distillation
  • Engineered bamboo
  • Forestry
  • List of woods
  • Mulch
  • Non-timber forest products
  • Papermaking
  • Wood drying
  • Wood preservation
  • Wood processing
  • Woodworking
  • Commons
  • WikiProject Forestry

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=I-joist&oldid=1234558319"

    Categories: 
    Building materials
    Engineered wood
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
    Wikipedia articles needing clarification from December 2023
     



    This page was last edited on 15 July 2024, at 00:07 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki