Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Contents  





2 Annex  





3 History  





4 References  














IEEE 693







Add links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


The IEEE 693: Recommended Practice for Seismic Design of Substations.[1] is a Institute of Electrical and Electronics Engineers standard. This standard is recognized also by American National Standards Institute, and is used mainly in the American Continent.[2]

The goal of the standard is to provide a single set of rules and regulations that cover the seismic design of both new and existing electrical substations, hence leading to standardization.[3] The standard provides the minimum requirements that the design of an electrical substation (except nuclear power plants) must adhere to. The norm includes the design of circuit breakers, transformers, disconnect and grounding switches, instrument transformers, circuit switches, surge arresters, and other equipment.[4]

Contents[edit]

The norm contains the 8 chapters named below:[5]

  1. Overview
  2. Normative references
  3. Definitions, acronyms, and abbreviations
  4. Instructions
    1. General
    2. Specifying this recommended practice in user's specification
    3. Standardization of criteria
    4. Selection of qualification level
    5. Witnessing of shake-table testing
    6. Optional qualification methods
    7. Qualifying equipment by group
    8. Inherently acceptable equipment
    9. Shake-table facilities
    10. Equipment too large to be tested in its in-service configuration
    11. Report templates
  5. Installation considerations
    1. General
    2. Equipment assembly
    3. Site response characteristics
    4. Soil-structure interaction
    5. Support structures
    6. Base isolation
    7. Suspended equipment
    8. Anchorage
    9. Conductor induced loading
      1. Interconnections with adjacent equipment
      2. Observed component displacements
      3. Decoupling equipment through flexible bus-work
      4. Conductor installation
    10. Short-circuit loads
    11. Wind and ice loads
  6. Qualification methods: an overview
    1. General
    2. Analysis methods
      1. Static analysis
      2. Static coefficient analysis
      3. Response spectrum dynamic analysis
      4. Time history dynamic analysis
    3. Testing methods
    4. Special test cases
    5. Qualification method for specific equipment
    6. Functionality of equipment
    7. Qualification by seismic experience data
    8. Response spectra
    9. Damping
  7. Design considerations
    1. Structural supports, excluding foundations
    2. Foundation analysis
    3. Station service
    4. Emergency power systems
    5. Telecommunication quipment
  8. Seismic performance criteria for electrical substation equipment
    1. Introduction
    2. Objective
    3. Seismic qualification levels
      1. High seismic level
      2. Moderate seismic level
      3. Low seismic level
    4. Projected performance
      1. Performance levels
        1. High
        2. Moderate
        3. Low
    5. Seismic qualification
      1. High and moderate seismic qualification levels
      2. Low seismic qualification level
    6. Selecting the seismic level for seismic qualification

The norm specifies 3 seismic qualification levels (high, medium, low).[6] The Zero Period Acceleration (ZPA) (a.k.a. Peak Ground Acceleration) for the high and the medium qualifications levels are set to be 0.5g and 0.25 respectively (no calculation is required for equipment with "low" qualification), where g stands for acceleration due to gravity. The Peak Acceleration (i.e. the peak of the Response Spectrum) at 2% damping is lower than 1.65g and 0.85g for high and medium qualification respectively, with the cutoff frequency defined as 33Hz.[3]

The qualification is allowed through one of the following:[7]

The norm suggests that most equipment in the same area be given the same qualification level (for interchangeability and redundancy).

Annex[edit]

There are a total of 22 annexes in the standard, 19 of which are normative, and the other 3 are informative.[5]

History[edit]

The first version of the standard was released in 1997, with a revised version released in 2005 and later in 2018.[9]

References[edit]

  1. ^ "IEEE Standards Association". IEEE Standards Association. Retrieved 2024-01-04.
  • ^ https://www.researchgate.net/publication/333402654_Overview_of_Major_Seismic_Standards_for_High_Voltage_Electrical_Equipment_Proposal_for_Harmonization_of_IEC_62271-207_with_IEEE_693
  • ^ a b KING, Alan; FRONK, Rulon (Aug 2004). "AN OVERVIEW OF IEEE 693 – IEEE RECOMMENDED PRACTICE FOR THE SEISMIC DESIGN OF SUBSTATIONS" (PDF).
  • ^ "IEEE 693". TRU Compliance. Retrieved 2024-01-11.
  • ^ a b IEEE Recommended Practice for Seismic Design of Substations (PDF). doi:10.1109/IEEESTD.2019.8686442. ISBN 978-1-5044-5486-5. Retrieved 2024-01-09.
  • ^ Kotanidis, Christos (2018-06-01). "IEEE 693-2005 Required Response Spectra (RRS) for various damping..." ResearchGate. Retrieved 2023-01-09.
  • ^ Kelechava, Brad (2019-05-16). "IEEE Recommended Practice for Seismic Design of Substations". The ANSI Blog. Retrieved 2024-01-09.
  • ^ Kotanidis, Christos; Palaiochorinou, Anastasia (2018-06-01). "Overview of Major Seismic Standards for High Voltage Electrical Equipment. Proposal for Harmonization of IEC 62271-207 with IEEE 693". ResearchGate. Retrieved 2023-01-09.
  • ^ Fujisaki, Eric; Kempner, Leon; Knight, Brian; Riker, Craig (November 2018). Seismic Design of Substations—IEEE Standard 693 Gets a Major Update. American Society of Civil Engineers. pp. 219–232. doi:10.1061/9780784481837.021. ISBN 978-0-7844-8183-7. S2CID 215940532.

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=IEEE_693&oldid=1196534792"

    Category: 
    Institute of Electrical and Electronics Engineers
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
     



    This page was last edited on 17 January 2024, at 20:14 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki