1 Differences from high dead space syringes  





2 History of needle and syringe designs  



2.1  Various designs of low dead space syringes  







3 Designs  



3.1  Fixed needle design  





3.2  Detachable needle design  







4 WHO guidelines for people who inject drugs  





5 Benefits of low dead space syringes  





6 Criticism of low dead space syringe distribution  





7 References  














Low dead space syringe







 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Alow dead space syringe (LDSS) or low dead-volume syringe is a type of syringe with a design that seeks to limit dead space that exists between the syringe hub and needle.

Differences from high dead space syringes[edit]

1-ml syringe design yields 2 micro literes and standard syringe and needle hub yield 84 micro liters on average.
Example a low and high dead space syringe and the average fluid remaining after complete depression of the plunger.

The difference between high and low dead space syringes is determined by the average quantity of fluid that cannot be expelled from the device. Although no set standard for the designation of low dead space syringes and needles exists, it is the convention to designate any needle or syringe design that deviates from the standard needle and syringe design as low dead space if this new design yields a lower dead space.[1]

As opposed to low dead space syringes, high dead space syringes are conventional needle and syringe designs. The term "high dead space" refers to the fluid remaining within the needle and between the syringe hub and the plunger. This space can be as high as 84 micro liters in conventional syringes.[2] Conventional high dead space syringes have existed since the mass production of plastic syringes with removable needles in 1961.[3]

However, there are problems associated with the dead space in syringes: medication waste,[4] disease transmission,[2] and inaccurate dosing.[5] Specifically, there is some data to suggest that disease transmission for people who inject drugs and carry Hepatitis C virus can be reduced with the use of low dead space syringes.[6] Low dead space syringes reduce this risk by minimizing the amount of space within the syringe for blood to enter.[7]

History of needle and syringe designs[edit]

The first hypodermic needle was first used by Dr. Alexander Wood and immediately efforts were made to improve the design. It was not until 1954, with the need for massive syringe distribution of Dr. Salk's polio vaccine, that the first disposable syringes were created. Initially, they were made of glass. In 1961 plastic disposable syringes became available.[8] The advent of the first low dead space syringe occurred with the creation of 1-ml syringes designed specifically for the administration of insulin. Then amongst the scare of HIV and rising concern of other communicable diseases to healthcare workers the creation of safety syringes occurred in 1988. As of the last few years new designs have emerged that work on a needle that is low dead space and fits onto and transforms high dead space syringes into low dead space syringes. One design achieves this by creating a plunger that inserts itself into the syringe neck to expel as much fluid as possible from the syringe body, thus reducing the amount of space available within the neck.[9]

Various designs of low dead space syringes[edit]

Standard high dead space needle and syringe with extended plunger
1-ml syringe, "insulin syringe"
Standard high dead space syringe with low dead space needle

Designs[edit]

Fixed needle design[edit]

The insulin syringe was the first syringe that is considered low dead space. It was initially created with low dead space for accurate measuring and mixing of fast and slow acting insulin, which had the added benefit of wasting as little of the expensive drug as possible. An attached short and small gauge needle was also designed into the syringe to prevent the needle from detaching during administration of insulin and to decrease pain from frequent injections.[9]

Detachable needle design[edit]

Low dead space can be achieved in detachable syringes and needles through designing either the syringe or needle components to have low dead space.

Currently, the design of the low dead space needle incorporates a plastic neck that fits within the neck of a standard syringe hub.

A low dead space syringe is accomplished by using a standard syringe body with an extended plunger that inserts into the neck of the syringe body to expel more fluid from the syringe.

WHO guidelines for people who inject drugs[edit]

According to WHO guidelines for people who inject drugs it is suggested that needle exchange programs provide low dead space syringes for distribution to people who inject drugs due to evidence that the provision of low dead space syringes leads to a reduction in the transmission of HIV, and hepatitis B and C.[10][11]

Benefits of low dead space syringes[edit]

Criticism of low dead space syringe distribution[edit]

Critics of low dead space syringe distribution to needle exchange programs claim that real world pilot studies do not exist to support findings within labs. Some proponents point to America and its low prevalence of HIV and hepatitis among people who inject drugs and cite the reason for such low prevalence to low dead space syringes already being the standard preferred syringe in the United States and successful anti-needle sharing campaigns. Other critics argue that countries like Vietnam, where low dead space needles are distributed and available, have the highest rates of HIV among people who inject drugs. However, proponents claim that low dead space syringes are still difficult to get and many people who use low dead space syringes still use high dead space syringes and thus reduce the potential effect of using low dead space syringes.[13][14]

References[edit]

  1. ^ Modeling the effect of high dead‐space syringes on the human immunodeficiency virus (HIV) epidemic among injecting drug users Bobashev, Georgiy V.; Zule, William A. Addiction, 2010, Vol.105(8), pp.1439-1447, 2010
  • ^ a b c Modeling the effect of high dead‐space syringes on the human immunodeficiency virus (HIV) epidemic among injecting drug users. Addiction [0965-2140] Bobashev yr:2010 vol:105 iss:8 pg:1439 -1447
  • ^ "Why the Invention of the Syringe Was a Game Changer". Archived from the original on April 27, 2012.
  • ^ a b c Strauss K, van Zundert A, Frid A, Costigliola V. "Pandemic influenza preparedness: the critical role of the syringe". Erembodegem-Dorp 86, European Medical Association
  • ^ a b Inadvertent overdosing of neonates as a result of the dead space of the syringe hub and needle. Archives of Disease in Childhood: Fetal and Neonatal Edition [1359-2998] Bhambhani yr:2005 vol:90 iss:5 pg:F444 -5
  • ^ Trickey, A., May, M. T., Hope, V., Ward, Z., Desai, M., Heinsbroek, E., . . . Vickerman, P. (2018). Usage of low dead space syringes and association with hepatitis C prevalence amongst people who inject drugs in the UK. Drug and Alcohol Dependence, 192, 118-124. doi:10.1016/j.drugalcdep.2018.07.041
  • ^ Carroll, Jennifer J. (15 June 2019). Narkomania: Drugs, HIV, and Citizenship in Ukraine. Cornell University Press. p. 47. ISBN 978-1-5017-3693-3.
  • ^ Howard-Jones, N. A Critical Study of the Origins and Early Development of Hypodermic Medication
  • ^ a b "Archived copy" (PDF). Archived from the original (PDF) on 2015-05-08. Retrieved 2016-02-08.{{cite web}}: CS1 maint: archived copy as title (link)
  • ^ http://apps.who.int/iris/bitstream/10665/77969/1/9789241504379_eng.pdf [bare URL PDF]
  • ^ http://apps.who.int/iris/bitstream/10665/75357/1/9789241504041_eng.pdf [bare URL PDF]
  • ^ Rannou, M. Lheureux, N. Prangere, T. Legrand, J. Huglo, D. (2012) Absorption of radiopharmaceuticals to plastic syringes: Measurement and consequences. European Journal of Nuclear Medicine and Molecular Imaging. (39)S528-S529.
  • ^ Low dead space syringes: Authors’ response Zule, William A.; Cross, Harry E.; Stover, John; Pretorius, Carel International Journal of Drug Policy, 2013, Vol.24(1), pp.21-22, 2013
  • ^ Could low dead-space syringes really reduce HIV transmission to low levels? International Journal of Drug Policy [0955-3959] Vickerman yr:2013 vol:24 iss:1 pg:8 -14

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Low_dead_space_syringe&oldid=1191537607"

    Category: 
    Medical equipment
    Hidden categories: 
    CS1 maint: archived copy as title
    All articles with bare URLs for citations
    Articles with bare URLs for citations from March 2022
    Articles with PDF format bare URLs for citations
    Articles needing additional references from February 2021
    All articles needing additional references
     



    This page was last edited on 24 December 2023, at 04:20 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki