(Top)
 


1 Types of electrical currents used  





2 Equipment  





3 Demagnetizing parts  





4 Magnetic particle powder  



4.1  Magnetic particle carriers  







5 Inspection  





6 Standards  





7 References  





8 Further reading  





9 External links  














Magnetic particle inspection






Čeština
Deutsch
Español
فارسی
Français

Italiano
עברית


Polski
Svenska
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 




In other projects  



Wikimedia Commons
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 

(Redirected from Magnetic-particle inspection)

A technician performs MPI on a pipeline to check for stress corrosion cracking using what is known as the "black on white" method. No indications of cracking appear in this picture; the only marks are the "footprints" of the magnetic yoke and drip marks.
A close-up of the surface of a (different) pipeline showing indications of stress corrosion cracking (two clusters of small black lines) revealed by MPI. Cracks that would normally have been invisible are detectable due to the magnetic particles clustering at the crack openings. The scale at the bottom is numbered in centimetres.

Magnetic particle inspection (MPI) is a nondestructive testing process where a magnetic field is used for detecting surface, and shallow subsurface, discontinuities in ferromagnetic materials. Examples of ferromagnetic materials include iron, nickel, cobalt, and some of their alloys. The process puts a magnetic field into the part. The piece can be magnetized by direct or indirect magnetization. Direct magnetization occurs when the electric current is passed through the test object and a magnetic field is formed in the material. Indirect magnetization occurs when no electric current is passed through the test object, but a magnetic field is applied from an outside source. The magnetic lines of force are perpendicular to the direction of the electric current, which may be either alternating current (AC) or some form of direct current (DC) (rectified AC).

The presence of a surface or subsurface discontinuity in the material allows the magnetic flux to leak, since air cannot support as much magnetic field per unit volume as metals.

To identify a leak, ferrous particles, either dry or in a wet suspension, are applied to a part. These are attracted to an area of flux leakage and form what is known as an indication, which is evaluated to determine its nature, cause, and course of action, if any.

Types of electrical currents used[edit]

There are several types of electrical currents used in magnetic particle inspection. For a proper current to be selected one needs to consider the part geometry, material, the type of discontinuity one is seeking, and how far the magnetic field needs to penetrate into the part.

An AC electromagnet is the preferred method for find surface breaking indication. The use of an electromagnet to find subsurface indications is difficult. An AC electromagnet is a better means to detect a surface indication than HWDC, DC, or permanent magnet, while some form of DC is better for subsurface defects.

Equipment[edit]

A wet horizontal MPI machine with a 36 in (910 mm) coil
Using a similar machine, a U.S. Navy technician sprays magnetic particles on a test part under ultraviolet light.
An automatic wet horizontal MPI machine with an external power supply, conveyor, and demagnetizing system. It is used to inspect engine cranks.

A wet horizontal MPI machine is the most commonly used mass-production inspection machine. The machine has a head and tail stock where the part is placed to magnetize it. In between the head and tail stock is typically an induction coil, which is used to change the orientation of the magnetic field by 90° from the head stock. Most of the equipment is built for a specific application.

Mobile power packs are custom-built magnetizing power supplies used in wire wrapping applications.

Magnetic yoke is a hand-held device that induces a magnetic field between two poles. Common applications are for outdoor use, remote locations, and weld inspection. The drawback of magnetic yokes is that they only induce a magnetic field between the poles, so large-scale inspections using the device can be time-consuming. For proper inspection the yoke needs to be rotated 90 degrees for every inspection area to detect horizontal and vertical discontinuities. Subsurface detection using a yoke is limited. These systems used dry magnetic powders, wet powders, or aerosols.

Demagnetizing parts[edit]

A pull through AC demagnetizing unit

After the part has been magnetized it needs to be demagnetized. This requires special equipment that works the opposite way of the magnetizing equipment. The magnetization is normally done with a high current pulse that reaches a peak current very quickly and instantaneously turns off leaving the part magnetized. To demagnetize a part, the current or magnetic field needed has to be equal to or greater than the current or magnetic field used to magnetize the part. The current or magnetic field is then slowly reduced to zero, leaving the part demagnetized. A popular method to record residual magnetism is by using a Gauss meter.[2]

Magnetic particle powder[edit]

A common particle used to detect cracks is iron oxide, for both dry and wet systems.

After applying wet magnetic particles, a U.S. navy technician examines a bolt for cracks under ultraviolet light.

Magnetic particle carriers[edit]

It is common industry practice to use specifically designed oil and water-based carriers for magnetic particles. Deodorized kerosene and mineral spirits have not been commonly used in the industry for 40 years.[when?] It is dangerous to use kerosene or mineral spirits as a carrier due to the risk of fire.

Inspection[edit]

The following are general steps for inspecting on a wet horizontal machine:

  1. Workpiece is cleaned of oil and other contaminants.
  2. Necessary calculations done to know the amount of current required to magnetize the workpiece. Refer ASTM E1444/E1444M for formulas.
  3. The magnetizing pulse is applied for 0.5 seconds, during which the operator washes the workpiece with the particle, stopping before the magnetic pulse is completed. Failure to stop prior to end of the magnetic pulse will wash away indications.
  4. UV light is applied while the operator looks for indications of defects that are 0 to ±45 degrees from path the current flowed through the workpiece. Indications only appear 45 to 90 degrees of the magnetic field applied. The easiest way to quickly determine the direction of the magnetic field is running is to grasp the workpiece with either hand between the head stocks laying the thumb against the workpiece (do not wrap the thumb around the workpiece) this is called either left or right thumb rule or right hand grip rule. The direction the thumb points reveals the direction current is flowing. The magnetic field will be running 90 degrees from the current path. On complex geometry, like a crankshaft, the operator needs to visualize the changing direction of the current and magnetic field created. The current starts at 0 degrees then 45 degrees to 90 degree back to 45 degrees to 0 then -45 to -90 to -45 to 0 and this is repeated for each crankpin. Thus, it can be time consuming to find indications that are only 45 to 90 degrees from the magnetic field.
  5. The workpiece is either accepted or rejected, based on pre-defined criteria.
  6. The workpiece is demagnetized.
  7. Depending on requirements, the orientation of the magnetic field may need to be changed 90 degrees to inspect for indications that cannot be detected from steps 3 to 5. The most common way to change magnetic field orientation is to use a "coil shot". In Fig 1 a 36-inch coil can be seen then steps 4, 5, and 6 are repeated.

Standards[edit]

International Organization for Standardization (ISO)
European Committee for Standardization (CEN)
American Society of Testing and Materials (ASTM)
Canadian Standards Association (CSA)
Society of Automotive Engineers (SAE)
United States Military Standard

References[edit]

  1. ^ Betz, C. E. (1985), Principles of Magnetic Particle Testing (PDF), American Society for Nondestructive Testing, p. 234, ISBN 978-0-318-21485-6, archived from the original (PDF) on 2011-07-14, retrieved 2010-03-02.
  • ^ The Graduate Engineer (2 November 2021). "What Is MPI (Magnetic Particle Inspection)?". TheGraduateEngineer.com. The Graduate Engineer. Retrieved 16 November 2021.
  • Further reading[edit]

    External links[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Magnetic_particle_inspection&oldid=1210820468"

    Categories: 
    Nondestructive testing
    Casting (manufacturing)
    Welding
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
    Articles needing additional references from April 2010
    All articles needing additional references
    Wikipedia articles needing clarification from February 2016
    All articles with vague or ambiguous time
    Vague or ambiguous time from April 2021
    Commons category link is on Wikidata
    Articles with LCCN identifiers
    Articles with NDL identifiers
    Articles with NKC identifiers
     



    This page was last edited on 28 February 2024, at 14:02 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki