Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  



























Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Applications  



1.1  Weld verification  





1.2  Structural mechanics  





1.3  Relation to medical procedures  







2 Notable events in academic and industrial NDT  





3 ISO 9712  





4 Methods and techniques  





5 Personnel training, qualification and certification  



5.1  Certification schemes  





5.2  Levels of certification  







6 Terminology  





7 Reliability and statistics  





8 See also  





9 References  



9.1  Bibliography  







10 External links  














Nondestructive testing






العربية
 / Bân-lâm-gú
Čeština
Dansk
Español
Euskara
فارسی
Français

Hrvatski
Bahasa Indonesia
Italiano
עברית
Қазақша
Bahasa Melayu
Nederlands

Norsk bokmål
Polski
Português
Română
Русский
Srpskohrvatski / српскохрватски
Suomi
ி
Türkçe
Українська
Tiếng Vit

 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 




In other projects  



Wikimedia Commons
 


















From Wikipedia, the free encyclopedia
 


X-ray vault
X-ray vault used in Radiography

Nondestructive testing (NDT) is any of a wide group of analysis techniques used in science and technology industry to evaluate the properties of a material, component or system without causing damage.[1] The terms nondestructive examination (NDE), nondestructive inspection (NDI), and nondestructive evaluation (NDE) are also commonly used to describe this technology.[2] Because NDT does not permanently alter the article being inspected, it is a highly valuable technique that can save both money and time in product evaluation, troubleshooting, and research. The six most frequently used NDT methods are eddy-current, magnetic-particle, liquid penetrant, radiographic, ultrasonic, and visual testing.[3] NDT is commonly used in forensic engineering, mechanical engineering, petroleum engineering, electrical engineering, civil engineering, systems engineering, aeronautical engineering, medicine, and art.[1] Innovations in the field of nondestructive testing have had a profound impact on medical imaging, including on echocardiography, medical ultrasonography, and digital radiography.

Non-Destructive Testing (NDT/ NDT testing) Techniques or Methodologies allow the investigator to carry out examinations without invading the integrity of the engineering specimen under observation while providing an elaborate view of the surface and structural discontinuities and obstructions. The personnel carrying out these methodologies require specialized NDT Training as they involve handling delicate equipment and subjective interpretation of the NDT inspection/NDT testing results.

NDT methods rely upon use of electromagnetic radiation, sound and other signal conversions to examine a wide variety of articles (metallic and non-metallic, food-product, artifacts and antiquities, infrastructure) for integrity, composition, or condition with no alteration of the article undergoing examination. Visual inspection (VT), the most commonly applied NDT method, is quite often enhanced by the use of magnification, borescopes, cameras, or other optical arrangements for direct or remote viewing. The internal structure of a sample can be examined for a volumetric inspection with penetrating radiation (RT), such as X-rays, neutrons or gamma radiation. Sound waves are utilized in the case of ultrasonic testing (UT), another volumetric NDT method – the mechanical signal (sound) being reflected by conditions in the test article and evaluated for amplitude and distance from the search unit (transducer). Another commonly used NDT method used on ferrous materials involves the application of fine iron particles (either suspended in liquid or dry powder – fluorescent or colored) that are applied to a part while it is magnetized, either continually or residually. The particles will be attracted to leakage fields of magnetism on or in the test object, and form indications (particle collection) on the object's surface, which are evaluated visually. Contrast and probability of detection for a visual examination by the unaided eye is often enhanced by using liquids to penetrate the test article surface, allowing for visualization of flaws or other surface conditions. This method (liquid penetrant testing) (PT) involves using dyes, fluorescent or colored (typically red), suspended in fluids and is used for non-magnetic materials, usually metals.

Analyzing and documenting a nondestructive failure mode can also be accomplished using a high-speed camera recording continuously (movie-loop) until the failure is detected. Detecting the failure can be accomplished using a sound detector or stress gauge which produces a signal to trigger the high-speed camera. These high-speed cameras have advanced recording modes to capture some non-destructive failures.[4] After the failure the high-speed camera will stop recording. The captured images can be played back in slow motion showing precisely what happened before, during and after the nondestructive event, image by image.

Applications[edit]

NDT is used in a variety of settings that covers a wide range of industrial activity, with new NDT methods and applications, being continuously developed. Nondestructive testing methods are routinely applied in industries where a failure of a component would cause significant hazard or economic loss, such as in transportation, pressure vessels, building structures, piping, and hoisting equipment.

Weld verification[edit]

  1. Section of material with a surface-breaking crack that is not visible to the naked eye.
  2. Penetrant is applied to the surface.
  3. Excess penetrant is removed.
  4. Developer is applied, rendering the crack visible.

In manufacturing, welds are commonly used to join two or more metal parts. Because these connections may encounter loads and fatigue during product lifetime, there is a chance that they may fail if not created to proper specification. For example, the base metal must reach a certain temperature during the welding process, must cool at a specific rate, and must be welded with compatible materials or the joint may not be strong enough to hold the parts together, or cracks may form in the weld causing it to fail. The typical welding defects (lack of fusion of the weld to the base metal, cracks or porosity inside the weld, and variations in weld density) could cause a structure to break or a pipeline to rupture.

Welds may be tested using NDT techniques such as industrial radiographyorindustrial CT scanning using X-raysorgamma rays, ultrasonic testing, liquid penetrant testing, magnetic particle inspection or via eddy current. In a proper weld, these tests would indicate a lack of cracks in the radiograph, show clear passage of sound through the weld and back, or indicate a clear surface without penetrant captured in cracks.

Welding techniques may also be actively monitored with acoustic emission techniques before production to design the best set of parameters to use to properly join two materials.[5] In the case of high stress or safety critical welds, weld monitoring will be employed to confirm the specified welding parameters (arc current, arc voltage, travel speed, heat input etc.) are being adhered to those stated in the welding procedure. This verifies the weld as correct to procedure prior to nondestructive evaluation and metallurgy tests.

Structural mechanics[edit]

Structure can be complex systems that undergo different loads during their lifetime, e.g. Lithium-ion batteries.[6] Some complex structures, such as the turbo machinery in a liquid-fuel rocket, can also cost millions of dollars. Engineers will commonly model these structures as coupled second-order systems, approximating dynamic structure components with springs, masses, and dampers. The resulting sets of differential equations are then used to derive a transfer function that models the behavior of the system.

In NDT, the structure undergoes a dynamic input, such as the tap of a hammer or a controlled impulse. Key properties, such as displacementoracceleration at different points of the structure, are measured as the corresponding output. This output is recorded and compared to the corresponding output given by the transfer function and the known input. Differences may indicate an inappropriate model (which may alert engineers to unpredicted instabilities or performance outside of tolerances), failed components, or an inadequate control system.

Reference standards, which are structures that intentionally flawed in order to be compared with components intended for use in the field, are often used in NDT. Reference standards can be with many NDT techniques, such as UT,[7]RT[8] and VT.

Relation to medical procedures[edit]

Chest radiography indicating a peripheral bronchial carcinoma.

Several NDT methods are related to clinical procedures, such as radiography, ultrasonic testing, and visual testing. Technological improvements or upgrades in these NDT methods have migrated over from medical equipment advances, including digital radiography (DR), phased array ultrasonic testing (PAUT), and endoscopy (borescope or assisted visual inspection).

Notable events in academic and industrial NDT[edit]

(Basic source for above: Hellier, 2001) Note the number of advancements made during the WWII era, a time when industrial quality control was growing in importance.

ISO 9712[edit]

This ISO 9712 requirements for principles for the qualification and certification of personnel who perform industrial non-destructive testing(NDT).[15]

The system specified in this International Standard can also apply to other NDT methods or to new techniques within an established NDT method, provided a comprehensive scheme of certification exists and the method or technique is covered by International, regional or national standards or the new NDT method or technique has been demonstrated to be effective to the satisfaction of the certification body.

The certification covers proficiency in one or more of the following methods: a) acoustic emission testing; b) eddy current testing; c) infrared thermographic testing; d) leak testing (hydraulic pressure tests excluded); e) magnetic testing; f) penetrant testing; g) radiographic testing; h) strain gauge testing; i) ultrasonic testing; j) visual testing (direct unaided visual tests and visual tests carried out during the application of another NDT method are excluded).

Methods and techniques[edit]

An example of a 3D replicating technique. The flexible high-resolution replicas allow surfaces to be examined and measured under laboratory conditions. A replica can be taken from all solid materials.

NDT is divided into various methods of nondestructive testing, each based on a particular scientific principle. These methods may be further subdivided into various techniques. The various methods and techniques, due to their particular natures, may lend themselves especially well to certain applications and be of little or no value at all in other applications. Therefore, choosing the right method and technique is an important part of the performance of NDT.

Personnel training, qualification and certification[edit]

Successful and consistent application of nondestructive testing techniques depends heavily on personnel training, experience and integrity. Personnel involved in application of industrial NDT methods and interpretation of results should be certified, and in some industrial sectors certification is enforced by law or by the applied codes and standards.[20]

NDT professionals and managers who seek to further their growth, knowledge and experience to remain competitive in the rapidly advancing technology field of nondestructive testing should consider joining NDTMA, a member organization of NDT Managers and Executives who work to provide a forum for the open exchange of managerial, technical and regulatory information critical to the successful management of NDT personnel and activities. Their annual conference at the Golden Nugget in Las Vegas is a popular for its informative and relevant programming and exhibition space

Certification schemes[edit]

There are two approaches in personnel certification:[21]

  1. Employer Based Certification: Under this concept the employer compiles their own Written Practice. The written practice defines the responsibilities of each level of certification, as implemented by the company, and describes the training, experience and examination requirements for each level of certification. In industrial sectors the written practices are usually based on recommended practice SNT-TC-1A of the American Society for Nondestructive Testing.[22] ANSI standard CP-189 outlines requirements for any written practice that conforms to the standard.[23] For aviation, space, and defense (ASD) applications NAS 410 sets further requirements for NDT personnel, and is published by AIA – Aerospace Industries Association, which is made up of US aerospace airframe and powerplant manufacturers. This is the basis document for EN 4179[24] and other (USA) NIST-recognized aerospace standards for the Qualification and Certification (employer-based) of Nondestructive Testing personnel. NAS 410 also sets the requirements also for "National NDT Boards", which allow and proscribe personal certification schemes. NAS 410 allows ASNT Certification as a portion of the qualifications needed for ASD certification.[25]
  2. Personal Central Certification: The concept of central certification is that an NDT operator can obtain certification from a central certification authority, that is recognized by most employers, third parties and/or government authorities. Industrial standards for central certification schemes include ISO 9712,[26] and ANSI/ASNT CP-106[27] (used for the ASNT ACCP [28] scheme). Certification under these standards involves training, work experience under supervision and passing a written and practical examination set up by the independent certification authority. EN 473[29] was another central certification scheme, very similar to ISO 9712, which was withdrawn when CEN replaced it with EN ISO 9712 in 2012.

In the United States employer based schemes are the norm, however central certification schemes exist as well. The most notable is ASNT Level III (established in 1976–1977), which is organized by the American Society for Nondestructive Testing for Level 3 NDT personnel.[30] NAVSEA 250-1500 is another US central certification scheme, specifically developed for use in the naval nuclear program.[31]

Central certification is more widely used in the European Union, where certifications are issued by accredited bodies (independent organizations conforming to ISO 17024 and accredited by a national accreditation authority like UKAS). The Pressure Equipment Directive (97/23/EC) actually enforces central personnel certification for the initial testing of steam boilers and some categories of pressure vessels and piping.[32] European Standards harmonized with this directive specify personnel certification to EN 473. Certifications issued by a national NDT society which is a member of the European Federation of NDT (EFNDT) are mutually acceptable by the other member societies [33] under a multilateral recognition agreement.

Canada also implements an ISO 9712 central certification scheme, which is administered by Natural Resources Canada, a government department.[34][35][36]

The aerospace sector worldwide sticks to employer based schemes.[37] In America it is based mostly on the Aerospace Industries Association's (AIA) AIA-NAS-410 [38] and in the European Union on the equivalent and very similar standard EN 4179.[24] However EN 4179:2009 includes an option for central qualification and certification by a National aerospace NDT boardorNANDTB (paragraph 4.5.2).

Levels of certification[edit]

Most NDT personnel certification schemes listed above specify three "levels" of qualification and/or certification, usually designated as Level 1, Level 2 and Level 3 (although some codes specify Roman numerals, like Level II). The roles and responsibilities of personnel in each level are generally as follows (there are slight differences or variations between different codes and standards):[26][24]

Terminology[edit]

The standard US terminology for Nondestructive testing is defined in standard ASTM E-1316.[39] Some definitions may be different in European standard EN 1330.

Indication
The response or evidence from an examination, such as a blip on the screen of an instrument. Indications are classified as trueorfalse. False indications are those caused by factors not related to the principles of the testing method or by improper implementation of the method, like film damage in radiography, electrical interference in ultrasonic testing etc. True indications are further classified as relevant and non relevant. Relevant indications are those caused by flaws. Non relevant indications are those caused by known features of the tested object, like gaps, threads, case hardening etc.
Interpretation
Determining if an indication is of a type to be investigated. For example, in electromagnetic testing, indications from metal loss are considered flaws because they should usually be investigated, but indications due to variations in the material properties may be harmless and nonrelevant.
Flaw
A type of discontinuity that must be investigated to see if it is rejectable. For example, porosity in a weld or metal loss.
Evaluation
Determining if a flaw is rejectable. For example, is porosity in a weld larger than acceptable by code?
Defect
A flaw that is rejectable – i.e. does not meet acceptance criteria. Defects are generally removed or repaired.[39]

Reliability and statistics[edit]

Probability of detection (POD) tests are a standard way to evaluate a nondestructive testing technique in a given set of circumstances, for example "What is the POD of lack of fusion flaws in pipe welds using manual ultrasonic testing?" The POD will usually increase with flaw size. A common error in POD tests is to assume that the percentage of flaws detected is the POD, whereas the percentage of flaws detected is merely the first step in the analysis. Since the number of flaws tested is necessarily a limited number (non-infinite), statistical methods must be used to determine the POD for all possible defects, beyond the limited number tested. Another common error in POD tests is to define the statistical sampling units (test items) as flaws, whereas a true sampling unit is an item that may or may not contain a flaw.[40][41] Guidelines for correct application of statistical methods to POD tests can be found in ASTM E2862 Standard Practice for Probability of Detection Analysis for Hit/Miss Data and MIL-HDBK-1823A Nondestructive Evaluation System Reliability Assessment, from the U.S. Department of Defense Handbook.

See also[edit]

References[edit]

  1. ^ a b Cartz, Louis (1995). Nondestructive Testing. A S M International. ISBN 978-0-87170-517-4.
  • ^ Charles Hellier (2003). Handbook of Nondestructive Evaluation. McGraw-Hill. p. 1.1. ISBN 978-0-07-028121-9.
  • ^ "Introduction to Nondestructive Testing". asnt.org.
  • ^ Bridges, Andrew (November 2013). "High Speed Cameras for Non-Destructive Testing". NASA TechBriefs. Retrieved 1 November 2013.
  • ^ Blitz, Jack; G. Simpson (1991). Ultrasonic Methods of Non-Destructive Testing. Springer-Verlag New York, LLC. ISBN 978-0-412-60470-6.
  • ^ Waldmann, T. (2014). "A Mechanical Aging Mechanism in Lithium-Ion Batteries". Journal of the Electrochemical Society. 161 (10): A1742–A1747. doi:10.1149/2.1001410jes.
  • ^ "EDM Notch Reference Standards » PH Tool". customers.phtool.com.
  • ^ "Radiography (RT) Reference Standards » PH Tool". customers.phtool.com.
  • ^ "Connecticut Digital Archive | Connect. Preserve. Share". collections.ctdigitalarchive.org. Retrieved 2019-08-18.
  • ^ "Today in History – Fales & Gray Explosion Underscores Need for a Hartford Hospital | Connecticut History | a CTHumanities Project". Retrieved 2019-08-17.
  • ^ "History of PI". www.ndt-ed.org. Archived from the original on 2009-08-23. Retrieved 2006-11-21.
  • ^ Singh S, Goyal A (2007). "The origin of echocardiography: a tribute to Inge Edler". Tex Heart Inst J. 34 (4): 431–8. PMC 2170493. PMID 18172524.
  • ^ U.S. Patent 3,277,302, titled "X-Ray Apparatus Having Means for Supplying An Alternating Square Wave Voltage to the X-Ray Tube", granted to Weighart on October 4, 1964, showing its patent application date as May 10, 1963 and at lines 1-6 of its column 4, also, noting James F. McNulty’s earlier filed co-pending application for an essential component of invention
  • ^ U.S. Patent 3,289,000, titled "Means for Separately Controlling the Filament Current and Voltage on a X-Ray Tube", granted to McNulty on November 29, 1966 and showing its patent application date as March 5, 1963
  • ^ "ISO 9712:2012 Non-destructive testing — Qualification and certification of NDT personnel".
  • ^ Ahi, Kiarash (2018). "A Method and System for Enhancing the Resolution of Terahertz Imaging". Measurement. 138: 614–619. Bibcode:2019Meas..138..614A. doi:10.1016/j.measurement.2018.06.044. S2CID 116418505.
  • ^ ASTM E1351: "Standard Practice for Production and Evaluation of Field Metallographic Replicas" (2006)
  • ^ BS ISO 3057 "Non-destructive testing - Metallographic replica techniques of surface examination" (1998)
  • ^ "Fundamentals of Resonant Acoustic Method NDT" (2005)
  • ^ "ICNDT Guide to Qualification and Certification of Personnel for NDT" (PDF). International Committee for NDT. 2012.
  • ^ John Thompson (November 2006). Global review of qualification and certification of personnel for NDT and condition monitoring. 12th A-PCNDT 2006 – Asia-Pacific Conference on NDT. Auckland, New Zealand.
  • ^ Recommended Practice No. SNT-TC-1A: Personnel Qualification and Certification in Nondestructive Testing, (2006)
  • ^ ANSI/ASNT CP-189: ASNT Standard for Qualification and Certification of Nondestructive Testing Personnel, (2006)
  • ^ a b c EN 4179: "Aerospace series. Qualification and approval of personnel for non-destructive testing" (2009)
  • ^ AIA NAS410
  • ^ a b ISO 9712: Non-destructive testing -- Qualification and certification of NDT personnel (2012)
  • ^ ANSI/ASNT CP-106: "ASNT Standard for Qualification and Certification of Nondestructive Testing Personnel" (2008)
  • ^ "ASNT Central Certification Program", ASNT Document ACCP-CP-1, Rev. 7 (2010)
  • ^ EN 473: Non-destructive testing. Qualification and certification of NDT personnel. General principles, (2008)
  • ^ Charles Hellier (2003). Handbook of Nondestructive Evaluation. McGraw-Hill. p. 1.25. ISBN 978-0-07-028121-9.
  • ^ Charles Hellier (2003). Handbook of Nondestructive Evaluation. McGraw-Hill. p. 1.26. ISBN 978-0-07-028121-9.
  • ^ Directive 97/23/EC of the European Parliament and of the Council of 29 May 1997 on the approximation of the laws of the Member States concerning pressure equipment, Annex I, paragraph 3.1.3
  • ^ EFNDT/SEC/P/05-006: Agreement for EFNDT multilateral recognition of NDT personnel certification schemes (2005)
  • ^ http://www.nrcan-rncan.gc.ca/smm-mms/ndt-end/index-eng.htm : The NDT Certifying Agency (CANMET-MTL)
  • ^ The relevant national standard for Canada is CAN/CGSB-48.9712-2006 "Qualification and Certification of Non-Destructive Testing Personnel.", which complies with the requirements of ISO 9712:2005 and EN 473:2000.
  • ^ Charles Hellier (2003). Handbook of Nondestructive Evaluation. McGraw-Hill. p. 1.27. ISBN 978-0-07-028121-9.
  • ^ R. Marini and P. Ranos: "Current Issues in Qualification and Certification of Non-Destructive Testing Personnel in the Aerospace Industry", ECNDT 2006 - Th.3.6.5
  • ^ AIA-NAS-410: "Aerospace Industries Association, National Aerospace Standard, NAS Certification and Qualification of Nondestructive Test Personnel"
  • ^ a b ASTM E-1316: "Standard Terminology for Nondestructive Examinations", The American Society for Testing and Materials, in Volume 03.03 NDT, 1997
  • ^ T. Oldberg and R. Christensen (1999). "Erratic Measure". 4 (5). NDT.net. {{cite journal}}: Cite journal requires |journal= (help)
  • ^ T. Oldberg (2005). "An Ethical Problem in the Statistics of Defect Detection Test Reliability". 10 (5). NDT.net. {{cite journal}}: Cite journal requires |journal= (help)
  • Bibliography[edit]

    • ASTM International, ASTM Volume 03.03 Nondestructive Testing
      • ASTM E1316-13a: "Standard Terminology for Nondestructive Examinations" (2013)
  • ASNT, Nondestructive Testing Handbook
  • Bray, D.E. and R.K. Stanley, 1997, Nondestructive Evaluation: A Tool for Design, Manufacturing and Service; CRC Press, 1996.
  • Charles Hellier (2003). Handbook of Nondestructive Evaluation. McGraw-Hill. ISBN 978-0-07-028121-9.
  • Shull, P.J., Nondestructive Evaluation: Theory, Techniques, and Applications, Marcel Dekker Inc., 2002.
  • EN 1330: Non-destructive testing. Terminology. Nine parts. Parts 5 and 6 replaced by equivalent ISO standards.
    • EN 1330-1: Non-destructive testing. Terminology. List of general terms (1998)
    • EN 1330-2: Non-destructive testing. Terminology. Terms common to the non-destructive testing methods (1998)
    • EN 1330-3: Non-destructive testing. Terminology. Terms used in industrial radiographic testing (1997)
    • EN 1330-4: Non-destructive testing. Terminology. Terms used in ultrasonic testing (2010)
    • EN 1330-7: Non-destructive testing. Terminology. Terms used in magnetic particle testing (2005)
    • EN 1330-8: Non-destructive testing. Terminology. Terms used in leak tightness testing (1998)
    • EN 1330-9: Non-destructive testing. Terminology. Terms used in acoustic emission testing (2009)
    • EN 1330-10: Non-destructive testing. Terminology. Terms used in visual testing (2003)
    • EN 1330-11: Non-destructive testing. Terminology. Terms used in X-ray diffraction from polycrystalline and amorphous materials (2007)
  • ISO 12706: Non-destructive testing. Penetrant testing. Vocabulary (2009)
  • ISO 12718: Non-destructive testing. Eddy current testing. Vocabulary (2008)
  • External links[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Nondestructive_testing&oldid=1225060309"

    Categories: 
    Nondestructive testing
    Maintenance
    Quality control
    Product testing
    Product certification
    Materials science
    Materials testing
    Tests
    Hidden categories: 
    CS1 errors: missing periodical
    Articles with short description
    Short description is different from Wikidata
    Wikipedia articles needing reorganization from August 2019
    Pages displaying wikidata descriptions as a fallback via Module:Annotated link
    Commons category link from Wikidata
    Articles with FAST identifiers
    Articles with BNE identifiers
    Articles with BNF identifiers
    Articles with BNFdata identifiers
    Articles with GND identifiers
    Articles with LCCN identifiers
    Articles with NDL identifiers
     



    This page was last edited on 22 May 2024, at 03:24 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki