Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Construction  





2 Applications  





3 Technical Considerations  





4 See also  





5 References  





6 Further reading  





7 External links  














Moving-bed heat exchanger







Add links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 

(Redirected from Moving bed heat exchanger)

Moving Bed Heat Exchangers (known as MBHEs) are widely used in industry, on applications involving heat recovery (providing a high volumetric transfer area) and filtering (avoiding common operational problems in fixed bed or ceramic filters like the pressure drop increase during operation).[1]

Construction[edit]

The MBHE is a gravity driven indirect heat exchanger using fine grained bulk material. Media moves along heat transfer surfaces which can be tubes, plates or panels. MBHEs offer the advantages of little external equipment, a compact design, low maintenance cost and low construction costs.[2]

The Moving Bed Heat Exchanger can consist of several heat exchanger modules arranged one above the other. The product leaves the heat exchanger via the discharge bottom and a funnel. The funnel can be equipped with a collecting screw conveyor if necessary. This does not affect the moving bed. A roof-shaped protecting screen can be installed above the heat exchanger modules to keep out agglomerates and impurities that cannot pass safely through the tube packages. Baffle plates can be installed to prevent wear of the protective screen. At the water/steam side, the ends of the heat exchanger packages (ends of the cooling water tubes) are fitted with reversing chambers and sealed with removable end plates.

On the product side, the outer tubes of the heat exchanger packages are equipped with steel plate strips at the sides. Their patented design keeps the product inside the heat exchanger - without the side walls obstructing access to the inside or interfering with the product movement. In addition, doors can be fitted (to protect the environment and the product quality).[3]

Applications[edit]

Moving bed heat exchangers can be used for cooling or warming of all free-flowing bulk materials which correspond to the requirements of the apparatus, concerning grain size and angle of repose. The heat exchangers often can be found after rotary kilns and dryers to cool e.g. mineral (quartz sand, Ilmentit, etc.) or chemical products (fertilizer, soda, etc.). The entry temperatures of the products can reach up to 1200 °C.

Recent interest in renewable energy storage options has led to interest in MBHEs for transfer and storage of energy. Thermal Energy Storage (TES) systems utilizing low cost sand have been proposed.[4]

A study was conducted on the use of a Moving Bed Heat Exchanger-Filter (MHEF) for removing fine dust particles from gases. The influence of a number of variables was examined, including gas velocities, solid velocities, gas temperatures and dust sizes. The collection efficiency was found to decrease with increasing temperature; the total collection efficiency decreases strongly when the solid velocity increases. A stable numerical model for filtration and heat exchange was developed that predicts the two dimensional transient response of both solid and fluid phases. The numerical model incorporates variation in void fraction, velocities and transport coefficient due to combined processes of filtration and heat exchange.[5]

Technical Considerations[edit]

Moving bed heat exchangers have a relatively compact construction. Because of the working principle they need only a small base. However, depending on their application they can build relatively high. Because of having only few moved parts they have low electrical requirements and are low-maintenance. Problems with noise or dust contamination of the environments do not occur.

Particulate materials are a promising heat storage and heat transfer media for high temperature applications such as industrial processes, conventional power plants or Concentrating Solar Power (CSP). The flow behavior of the bulk material not only influences the design of the heat exchanger, but also affects the thermal behavior, since the contact time at the walls strongly depends on particle flowability. Occurrence of attrition leads to a deteriorated flow pattern, because the mean grain size and bulk porosity decrease as grain size distribution widens. This has a significant impact on design considerations.[6] .

See also[edit]

References[edit]

  1. ^ A. Soria-Verdugo*, J. A. Almendros-Ibáñez, U. Ruiz-Rivas, D. Santana (2009). "Interdisciplinary Transport Phenomena V, Preliminary Proceedings ITP-07-701 Proceedings of ITP2007Interdisciplinary Transport Phenomena V: Fluid, Thermal, Biological, Materials and Space SciencesOctober 14-19, 2007, Bansko, Bulgaria ITP-07-70 EXERGY OPTIMIZATION IN A STEADY MOVING BED HEAT EXCHANGER". Annals of the New York Academy of Sciences. 1161 (1): 584–600. doi:10.1111/j.1749-6632.2009.04091.x. hdl:10016/1222. PMID 19426351. S2CID 205931225.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  • ^ Baumann (2014). "Moving Bed Heat Exchangers for Use with Heat Storage in Concentrating Solar Plants: A Multiphase Model". Heat Transfer Engineering. 35 (3): 224–231. Bibcode:2014HTrEn..35..224B. doi:10.1080/01457632.2013.825154. S2CID 122278113.
  • ^ "Moving Bed Heat Exchangers". Grenzebach. Retrieved 15 October 2013.
  • ^ Matthew Golob; Sheldon Jeter; Dennis Sadowski. "HEAT TRANSFER COEFFICIENT BETWEEN FLAT SURFACE AND SAND" (PDF). Georgia Institute of Technology. Archived from the original (PDF) on 16 October 2013. Retrieved 16 October 2013.
  • ^ V. Henriquez; A. Macias-Machin (1997). "Hot gas filtration, using a moving bed heat exchanger-filter (MHEF)". Chemical Engineering and Processing: Process Intensification. 36 (5): 353–361. doi:10.1016/S0255-2701(97)00017-2. hdl:10553/76690.
  • ^ Torsten Baumann; Stefan Zunft. "Properties of Granular Materials for Use as Heat Transfer Media for a Moving Bed Heat Exchanger in CSP Applications" (PDF). Institute of Technical Thermodynamics. Retrieved 16 October 2013.
  • Further reading[edit]

    External links[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Moving-bed_heat_exchanger&oldid=1195383292"

    Categories: 
    Heat exchangers
    Cooling technology
    Hidden category: 
    CS1 maint: multiple names: authors list
     



    This page was last edited on 13 January 2024, at 16:40 (UTC).