Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Design  



1.1  Time-domain implementation  





1.2  Spectral-domain implementation  







2 Applications  





3 Considerations  



3.1  Spatial resolution  





3.2  Signal-to-noise ratio  







4 References  














Multiple scattering low coherence interferometry







Add links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Multiple scattering low coherence interferometry (ms/LCI) is an imaging technique that relies on analyzing multiply scattered light in order to capture depth-resolved images from optical scattering media. With current applications primarily in medical imaging, has the advantage of a higher range since forward scattered light attenuates less with depth when compared to the specularly reflected light that is assessed in more conventional imaging methods such as optical coherence tomography.[1] This allows ms/LCI to image through up to 90 mean free scattering paths, compared to roughly 27 scattering MFPs in OCT and 1–2 scattering MFPs in confocal microscopy.[2]

Design[edit]

Time-domain implementation[edit]

Early implementations of ms/LCI were in the time domain using lock-in detection in order to take advantage of long scanning depths as well narrow detection bandwidths.[2] As in traditional OCT, the beam interference coherence gates the light in order to filter out photons that have not traveled a sufficient path length. The use of distinct, non-intersecting illumination and collection beams allows for time insensitive triangulation of the light that also considers physical depth penetration into the media in order to reject diffuse backscattering light such that only forward scattered photons are analyzed. Unlike traditional OCT, the measured forward scattered light is diverged by a lens in order to isolate the angular component to be compared with the reference arm. Due to the dominance of forward scattering photons at deeper penetration depths, this technique enjoys superior imaging depth and high detection throughput but suffers from long signal acquisition time and poor spatial resolution inherent to time-domain techniques.

Spectral-domain implementation[edit]

By adapting techniques used in spectroscopic OCT, ms/LCI can be done in the spectral domain in order to provide faster acquisition time and various multispectral capabilities, including the use of localized contrast agents.[1] As in OCT, enhanced depth imaging is used to place the zero-path delay point behind the focal volume in order to increase sensitivity. A broadband supercontinuum laser source as well as a customized spectrometer detector are implemented in order to access the spectral domain, and a short-time Fourier transform method is used to process the interferograms as in spectroscopic OCT.

Diagram of a hypothetical ms/LCI setup.

Applications[edit]

Because of enhanced depth penetration, this technique's most promising applications lie in resolving features that exist deeper in tissue than other techniques such as OCT are capable of doing. Studies have determined ms/LCI's feasibility in a variety of clinical applications, including assessing burn injuries, as well as in vivo imaging of rat skin with superior depth results when compared to OCT.[3]

Considerations[edit]

Spatial resolution[edit]

Photons originating from the focal plane detected by ms/LCI will undergo multiple scattering events which causes extra travel time and resulting longer path lengths than the signal would otherwise indicate. This axial shift will make photons appear like they appear deeper from the sample than they actually are.

The presence of multiple scattering events causes a distribution of path lengths that intrinsically blurs the image, resulting in a maximum millimeter-scale resolution which is substantially poorer than OCT which operates at a micrometer-scale resolution.

Because of anisotropic propagation of light in tissue, the lateral profile will spread out slowly relative to axial profile, resulting in an elongated image.

Spectral-domain ms/LCI uniquely needs to account for the wavelength dependence of scattering when interpreting the reflectance depth profile as well as the transfer of information between layers; light emerging from deeper portions of tissue experience loss from absorption and scattering at all layers above it.

Signal-to-noise ratio[edit]

Predictably, ms/LCI requires high signal sensitivity in order to detect high-depth multiply scattered photons. Lock-in amplifiers help to increase signal-to-noise ratio (SNR) of the signals in both cases, and the use of apertures and precise illumination angles can minimize the amount of scattered light detected from superficial depths.

In time-domain ms/LCI, long integration times and depth scans provide improved contrast and sensitivity while sacrificing acquisition time. The use of a balanced photoreceiver is helpful to increase signal-to-noise ratio in time-domain ms/LCI but is difficult to do in spectral-domain ms/LCI because the increased depth range results in higher modulation frequencies which are difficult to calibrate between spectrometers [4]

References[edit]

  1. ^ a b Matthews, Thomas E.; Giacomelli, Michael G.; Brown, William J.; Wax, Adam (1 December 2013). "Fourier domain multispectral multiple scattering low coherence interferometry". Applied Optics. 52 (34): 8220–8228. Bibcode:2013ApOpt..52.8220M. doi:10.1364/AO.52.008220. PMID 24513821. Retrieved 26 November 2018.
  • ^ a b Giacomelli, Michael G.; Wax, Adam (17 February 2011). "Imaging beyond the ballistic limit in coherence imaging using multiply scattered light". Optics Express. 19 (5): 4268–4279. Bibcode:2011OExpr..19.4268G. doi:10.1364/OE.19.004268. PMC 3368313. PMID 21369257. Retrieved 26 November 2018.
  • ^ Zhao, Yang; Maher, Jason R.; Ibrahim, Mohamed M.; Chien, Jennifer S.; Levinson, Howard; Wax, Adam (1 Oct 2016). "Deep imaging of absorption and scattering features by multispectral multiple scattering low coherence interferometry". Biomedical Optics Express. 7 (10): 3916–3926. doi:10.1364/BOE.7.003916. PMC 5102527. PMID 27867703. Retrieved 26 November 2018.
  • ^ Kuo, Wen-Chuan; Lai, Chih-Ming; Huang, Yi-Shiang; Chang, Cheng-Yi; Kuo, Yue-Ming (7 August 2013). "Balanced detection for spectral domain optical coherence tomography". Optics Express. 21 (16): 19280–19291. Bibcode:2013OExpr..2119280K. doi:10.1364/OE.21.019280. PMID 23938845. Retrieved 26 November 2018.

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Multiple_scattering_low_coherence_interferometry&oldid=1188360603"

    Categories: 
    Imaging
    Medical imaging
    Hidden categories: 
    Articles needing additional references from December 2018
    All articles needing additional references
     



    This page was last edited on 4 December 2023, at 22:46 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki