Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Glass tube bridges (KCl-type and ionic liquid salt bridge)  



1.1  KCl-type Salt Bridges  





1.2  Ionic Liquid Salt Bridges  







2 Filter paper bridges  





3 Charcoal salt bridges  





4 See also  





5 References  














Salt bridge






العربية
 / Bân-lâm-gú
Català
Deutsch
Español
فارسی
Français
Galego

Հայերեն
Bahasa Indonesia
Italiano
עברית
Nederlands

Norsk bokmål
Polski
Português

Svenska
Türkçe
Tiếng Vit

 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


An electrochemical cell (resembling a Daniell cell) with a filter paper salt bridge. The paper has been soaked with a Potassium nitrate solution.

Inelectrochemistry, a salt bridgeorion bridge is an essential laboratory device discovered over 100 years ago. [1] It contains an electrolyte solution, typically an inert solution, used to connect the oxidation and reduction half-cells of a galvanic cell (voltaic cell), a type of electrochemical cell. [1][2] In short, it functions as a link connecting the anode and cathode half-cells within an electrochemical cell.[3] It also maintains electrical neutrality within the internal circuit and stabilizes the junction potential between the solutions in the half-cells.[4] Additionally, it serves to minimize cross-contamination between the two half cells and helps concentrate our focus on unfolding the function of working electrodes of the half-cells. [1][5]

A salt bridge typically consists of tubes filled with an electrolyte solution. These tubes often have diaphragms such as glass frits at their ends to help contain the solution within the tubes and prevent excessive mixing with the surrounding environment.[3] When setting up a salt bridge between different solvents of half-cells, it is crucial to ensure that the electrolyte used in the bridge is soluble in both solutions and does not interact with any species present in either solutions. [3]

There are several types of salt bridges: glass tube bridges (traditional KCl-type salt bridge and ionic liquid salt bridge), filter paper bridges, porous frit salt bridges, fumed-silica, and agar gel salt bridges.

The following sections will explore in greater detail the characteristics and applications of glass tube bridges, filter paper bridges, fumed silica salt bridges, and charcoal salt bridges.

Glass tube bridges (KCl-type and ionic liquid salt bridge)[edit]

Glass tube salt bridges commonly consist of U-shaped Vycor tubes filled with a relatively inert electrolyte.[6] The electrolyte solution usually comprises a combination of cations, such as ammonium and potassium, and anions, including chloride and nitrate, which have similar mobility.[1][3] The combination is chosen which does not react with any of the chemicals used in the cell.

KCl-type Salt Bridges[edit]

Traditionally, concentrated aqueous potassium chloride (KCl) solution has been used for decades to neutralize the liquid-junction potential.[1] When comparing other salt solutions such as potassium bromide and potassium iodide to potassium chloride, potassium chloride is the most efficient in nullifying the junction potential.[1] Yet, the effectiveness of this salt bridge decreases as the ionic strength of the sample solution increases.[1]

Ionic Liquid Salt Bridges[edit]

Due to the numerous drawbacks of KCl-type salt bridges, ionic liquid salt bridges (ILSB) have been utilized to address the potentiometry issues arising from KCl-type salt bridges in electrochemical cells.[1][4] ILSBs demonstrate efficient performance in aqueous solutions of hydrophilic electrolytes. This is because ionic liquids do not mix with water - What??? as written, this statement makes no sense - contact author for explanation of immiscibility (they are immiscible), rendering them suitable as salt bridges for aqueous solutions.[1] Additionally, they are chemically inert and highly stable in water.[1]

The labeled salt bridge shows the U-shaped glass tube used as a salt bridge.


To set up a glass tube salt bridge, a U-shaped Vycor tube is fashioned to contain a suitable electrolyte solution. [3] Normally, glass frits, a porous material, cover the ends of the tube or the electrolyte is often gelified with agar-agar to help prevent the intermixing of fluids that might otherwise occur.[3]

The conductivity of a glass tube bridge primarily depends on the concentration of the electrolyte solution. At concentrations below saturation, an increase in concentration enhances conductivity. However, beyond-saturation electrolyte content and a narrow tube diameter may both reduce conductivity.[4]

Filter paper bridges[edit]

Porous paper such as filter paper may be used as a salt bridge if soaked in an appropriate electrolyte such as the electrolytes used in glass tube bridges. No gelification agent is required as the filter paper provides a solid medium for conduction. [7]

The conductivity of this kind of salt bridge depends on a number of factors: the concentration of the electrolyte solution, the texture of the paper, and the absorbing ability of the paper. Generally, smoother texture and higher absorbency equate to higher conductivity. [7]

To set up this type of salt bridge, laboratory filter paper can be used and rolled to form a shape that connects the two half-cells, typically rolled into a cylindrical shape.[7] The rolled filter paper is then soaked in an appropriate inert salt solution.[7] A straw can be used to shape the rolled filter paper into a U-shaped tube, providing mechanical strength to the soaked filter paper.[7][8] This filter paper can now be used to act as a salt bridge and connect the two half-cells.[7]

While filter paper salt bridges are inexpensive and easily accessible, one disadvantage of not using a straw to provide mechanical strength is that a new rolled and soaked filter paper must be used for each experiment.[7] Additionally, filter paper has limited longevity and poses a high risk of contamination.[3]

Charcoal salt bridges[edit]

A recent development is the charcoal salt bridge. It is considered an excellent option for a porous junction for the reference electrode in an alkaline solution.[9]

Charcoal (black box at the bottom of the cell) acts as a salt bridge to allow ion transfer.

A porous junction serves as a salt bridge between the two half-cells of reference and electrolyte solutions.[9] Other materials used for porous junctions, such as glass, Teflon, and agar gel, have their own benefits but also some significant drawbacks such as high cost and high risk of contamination.[9][3]

Therefore, the advantages of using charcoal as frits include its low cost and easy accessibility, as charcoal can be sourced from porous carbon materials.[9] Despite being fragile, charcoal facilitates efficient ion transfer due to its highly porous structure.[9]


See also[edit]

References[edit]

  1. ^ a b c d e f g h i j Kakiuchi, Takashi (2011-07-01). "Salt bridge in electroanalytical chemistry: past, present, and future". Journal of Solid State Electrochemistry. 15 (7): 1661–1671. doi:10.1007/s10008-011-1373-0. ISSN 1433-0768.
  • ^ "5. Electrochemical Cells". Chemistry LibreTexts. 2017-05-18. Retrieved 2024-04-07.
  • ^ a b c d e f g h Doménech-Carbó, Antonio (2013-11-01). "György Inzelt, Andrzej Lewenstam, and Fritz Scholz (eds.), Handbook of Reference Electrodes". Journal of Solid State Electrochemistry. 17 (11): 2967–2968. doi:10.1007/s10008-013-2160-x. ISSN 1433-0768.
  • ^ a b c Kakiuchi, Takashi (2014-08-01). "Ionic liquid salt bridge — Current stage and perspectives: A mini review". Electrochemistry Communications. 45: 37–39. doi:10.1016/j.elecom.2014.05.016. ISSN 1388-2481.
  • ^ Anderson, Evan L.; Troudt, Blair K.; Bühlmann, Philippe (2020). "Critical Comparison of Reference Electrodes with Salt Bridges Contained in Nanoporous Glass with 5, 20, 50, and 100 nm Diameter Pores". Analytical Sciences. 36 (2): 187–191. doi:10.2116/analsci.19P235.
  • ^ Clem, Ray G.; Jakob, Fredi.; Anderberg, Dane. (1971-02-01). "Fumed silica salt-bridges". Analytical Chemistry. 43 (2): 292–293. doi:10.1021/ac60297a014. ISSN 0003-2700.
  • ^ a b c d e f g Malike Devi, G.; Padmavathi, D. A.; Sanjeev, R.; Jagannadham, V. (2016). "Filter Paper Salt Bridge in Potentiometric Titrations: An Undergraduate Laboratory Chemical Education Article". World Journal of Chemical Education. 4 (6): 117–123 – via Science & Education Publishing.
  • ^ "CEJ Vol. 8, No. 2 (Serial No. 15). Reg. No. 8-11". www.edu.utsunomiya-u.ac.jp. Retrieved 2024-04-15.
  • ^ a b c d e Lee, Jun-Seob (2020-02-15). "Use of a charcoal salt bridge to a reference electrode in an alkaline solution". Journal of Electroanalytical Chemistry. 859: 113872. doi:10.1016/j.jelechem.2020.113872. ISSN 1572-6657.
  • t
  • e

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Salt_bridge&oldid=1227125436"

    Categories: 
    Electrochemical concepts
    Laboratory equipment
    Electrochemistry stubs
    Hidden categories: 
    Articles with short description
    Short description is different from Wikidata
    Use American English from April 2019
    All Wikipedia articles written in American English
    All stub articles
     



    This page was last edited on 3 June 2024, at 21:30 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki