1 Scope  





2 Provisions  



2.1  Recovery level  





2.2  Recording Requirements  





2.3  Leak Repair Requirements  





2.4  Leak Inspection Regulations  







3 Credentialing and Exams  





4 See also  





5 References  














Section 608







Add links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Section 608 (together with Section 609, which covers motor vehicles) of the Clean Air Act serves as the main form of occupational licensure for technicians in the heating, ventilation, and air conditioning (HVAC) industry in the United States.[1] The law requires that all persons who maintain, service, repair or dispose of appliances that contain regulated refrigerants be certified in proper refrigerant handling techniques.[2] The regulatory program helps to minimize the release of refrigerants, and in particular ozone depleting refrigerants such as chlorofluorocarbons and hydrofluorocarbons, as well as other regulated refrigerants as determined by Section 612. The licensure program complies with the requirements under the Montreal Protocol. The Environmental Protection Agency (EPA) published implementing regulations at 40 CFR Part 82.[3]

Scope[edit]

There are four categories of certification:

Type Application
I Persons who maintain, service or repair small appliances with less than 5 lbs of refrigerant.
II Persons who maintain, service, repair or dispose of high pressure appliances, except for small appliances.
III Persons who maintain, service, repair, or dispose of low pressure appliances.
Universal Persons who maintain, service, repair, or dispose of any appliance in categories of types I, II, or III.

A technician with the required level of certification may also legally purchase regulated refrigerants. And technicians who violate the Clean Air Act provisions may be fined, lose their certification, and may be required to appear in Federal court.[4]

Provisions[edit]

In general, along with general enforcement provisions, section 608 manages the following regulatory requirements:

Recovery level[edit]

For Type I systems the main requirement is to remove 80% of the refrigerant if the appliance's compressor is not running and 90% if running and evacuate to a 4 inch Hg vacuum.

For Type II or Type III applications, the appliance must be evacuated to the following levels for device manufactured after November 15, 1993 in order to recover the refrigerant

Application Required Evacuation
Very high pressure 0"Hg
High pressure w/<200 lbs of refrigerant 0"Hg
High pressure w/>=200 lbs of refrigerant 10"Hg
Medium pressure w/<200 lbs of refrigerant 10"Hg
Medium pressure w/>=200 lbs of refrigerant 15"Hg
Low pressure (Type III) 25mm Hg absolute

[6]

Where pressure classification of the refrigerant is defined by the refrigerant's pressure at 104F as

Type Pressure
Very High Pressure Above 355 psia
High Pressure Between 170 and 355 psia
Medium Pressure Between 45 psia and 170 psia
Low Pressure Below 45 psia

[7]

Recording Requirements[edit]

For systems containing 50 lbs or more of refrigerant, for each service, the owner must be supplied with information of:

And such records must be held for 3 years.[8]

Additionally, if an appliance leaks more than 125% of refrigerant, it must be reported to the EPA.[9]

Leak Repair Requirements[edit]

Leaks must be repaired in systems with greater than 50 lbs of refrigerant if the leak rate exceeds

Application Annual Leak Rate %
Industrial Process Refrigeration 30%
Commercial Refrigeration 20%
Comfort/Residential Cooling 10%

In which case, they must be repaired within 30 days/120 if industrial process shutdown is required. An initial verification test must then be done within 30/120 days, and then a follow-up test within 10 days of that. There are additional clauses for extensions if needed.

If the leak is not to be repaired, there must be a plan to retire or retrofit the appliance within 30 days, to be completed within one year. [10]

If more than a year is required, a report must be submitted, which must include:

Leak Inspection Regulations[edit]

Additional leak inspection frequencies following a leak must regard the following until the leak rate is within acceptable levels:

System Size Application Frequency
>=500lbs Industrial Process and Commercial Refrigeration Every 3 months for a year.
<500 lbs and >=50lbs Industrial Process and Commercial Refrigeration Annually
-- Comfort/Residential Cooling Annually

These leak inspections may be bypassed if the system is installed with an automatic leak detection system. [11]

Credentialing and Exams[edit]

EPA regulations require the test to be a "closed book" proctored exam. The only outside materials allowed are a temperature / pressure chart, scratch paper and a calculator. The certification exam contains 4 sections: Core, Type I, Type II, and Type III. Each section contains 25 multiple choice questions. The technician must achieve a passing score of 70% in each Type in which they are to be certified. All technicians must pass the CORE section before receiving any certification. A technician seeking certification must correctly answer 18 out of 25 questions on the CORE and at least one other section of the exam. A technician seeking Universal certification must correctly answer 18 out of 25 questions on each section of the exam.

In addition to covering EPA (in particular, Section 608) regulations, the exam also covers basic safety and occupational practices, along with fundamental concepts of stratospheric ozone protection (which are typically part of the Core exam).[2]

Many universities and colleges also have associate degrees and apprenticeship programs that teach HVAC fundamentals along with providing EPA examinations.[12][13][14]

See also[edit]

References[edit]

  1. ^ United States. Clean Air Act. "National recycling and emission reduction program." 42 U.S.C. 7671(g).
  • ^ a b "Section 608 Technician Certification". EPA. 2022-11-02.
  • ^ U.S. Environmental Protection Agency (EPA), Washington, D.C. Code of Federal Regulations, Title 40. "Part 82: Protection of Stratospheric Ozone. Subpart I: Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs."
  • ^ a b "EPA's Refrigerant Management Program: Questions and Answers for Section 608 Certified Technicians". 15 May 2018.
  • ^ "Section 608 of the Clean Air Act: Stationary Refrigeration and Air Conditioning" (PDF). EPA. EPA 430-F-18-001.
  • ^ "§ 82.156 Proper evacuation of refrigerant from appliances". eCFR. EPA.
  • ^ "§ 82.152 Definitions". eCFR. EPA.
  • ^ "§ 82.166 Reporting and recordkeeping requirements for leak repair". eCFR. EPA.
  • ^ "§ 82.157 Appliance maintenance and leak repair". eCFR. EPA.
  • ^ "§ 82.157 Appliance maintenance and leak repair". eCFR. EPA.
  • ^ "§ 82.157 Appliance maintenance and leak repair". eCFR. EPA.
  • ^ "Heating, Ventilating, Air Conditioning and Refrigeration". Big Rapids, MI: Ferris State University.
  • ^ "Heating, Air Conditioning & Refrigeration". Des Moines Area Community College. Retrieved 2023-03-20.
  • ^ "Section 608 Technician Certification Programs". EPA. 2023-02-22.


  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Section_608&oldid=1232307176"

    Categories: 
    Air pollution in the United States
    Environmental policy in the United States
    Heating, ventilation, and air conditioning
    Licensing
    Recycling by material
    Refrigerants
    Regulators of biotechnology products
    United States federal environmental legislation
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
    Wikipedia introduction cleanup from March 2023
    All pages needing cleanup
    Articles covered by WikiProject Wikify from March 2023
    All articles covered by WikiProject Wikify
     



    This page was last edited on 3 July 2024, at 02:12 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki