Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Design considerations  





2 Robustness requirements in Eurocodes  





3 See also  





4 References  





5 External links  














Structural robustness






العربية
Azərbaycanca
Беларуская
Чӑвашла
Deutsch
Հայերեն
Қазақша
Português
Русский
Svenska
Українська
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Robustness is the ability of a structure to withstand events like fire, explosions, impact or the consequences of human error, without being damaged to an extent disproportionate to the original cause – as defined in EN 1991-1-7 of the Accidental Actions Eurocode.[1]

A structure designed and constructed to be robust should not suffer from disproportionate collapse (progressive collapse) under accidental loading.[2] Buildings of some kinds, especially large-panel systems and precast concrete buildings, are disproportionately more susceptible to collapse; others, such as in situ cast concrete structures, are disproportionately less susceptible. The method employed in making a structure robust will typically depend on and be tailored to the kind of structure it is, as in steel framed building structural robustness is typically achieved through appropriately designing the system of connections between the frame's constituents.[2]

Design considerations[edit]

Three alternative measures are used, sometimes jointly, to achieve structural robustness and reduce the risk of disproportionate collapse.[3][4] These are:

Robustness requirements in Eurocodes[edit]

The requirements for structures in consequence classes 2 and 3 can be found in EN 1991-1-7 Eurocode 1 - Actions on structures - Part 1-7: General actions - Accidental actions. Additional requirements and requirements for structures in consequence class 1 can be found in the material specific Eurocode parts, EN 1992 for concrete structures, EN 1993 for steel structures and so on.

In EN 1991-1-7 buildings are categorised in consequences classes, considering the building type, occupancy and size.[1]

Consequence class 1, low consequences of failure:

Consequence class 2a, lower risk group - medium consequences of failure:

Consequence class 2b, upper risk group - medium consequences of failure:

Consequence class 3, high consequences of failure:

For buildings intended for more than one type of use, the consequences class should be that of the most onerous type.[2]

Buildings in consequence class 1 should be designed and constructed in accordance with EN 1990 - 1999 for satisfying stability in normal use, no specific consideration (required by EN 1991-1-7) is necessary with regard to accidental actions from unidentified causes.

Buildings in consequence class 2a (in addition to what is recommended for consequence class 1) should be provided with effective horizontal ties, or effective anchorage of suspended floors to walls.

Buildings in consequence class 2b (in addition to what is recommended for consequence class 1 and 2a) should be provided with effective vertical ties in all supporting columns and walls, or alternatively the building should be checked to ensure that upon the notional removal of each supporting column and each beam supporting a column, or any nominal section of load-bearing wall (one at a time in each storey of the building) the building remains stable and the local damage does not exceed a certain limit. Where the removal of such columns and sections of walls would result in an extent of damage in excess of the agreed limit, such elements should be designed as a key element.

For buildings in consequence class 3 a systematic risk assessment of the building taking into account both foreseeable and unforeseeable hazards, is required.

See also[edit]

References[edit]

  1. ^ a b EN 1991-1-7 Eurocode 1 - Actions on structures - Part 1-7: General actions - Accidental actions. CEN.
  • ^ a b c "Structural robustness". SteelConstruction.info. Retrieved 2013-06-15.
  • ^ "FIB bulletin 43 Structural connections for precast concrete buildings". FIB. Retrieved 2013-06-15.
  • ^ "International seminar on Precast Concrete Structures Accidental Actions and Progressive Collapse Arnold Van Acker" (PDF). Department of Civil Engineering Universidade Nova de Lisboa. Retrieved 2013-06-15.
  • External links[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Structural_robustness&oldid=1219172438"

    Categories: 
    Structural engineering
    Safety engineering
    Structural steel
    Concrete
    Infrastructure
    Civil engineering
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
    Articles with limited geographic scope from June 2023
    Europe-centric
    Pages displaying wikidata descriptions as a fallback via Module:Annotated link
    Pages displaying short descriptions of redirect targets via Module:Annotated link
    Articles with GND identifiers
     



    This page was last edited on 16 April 2024, at 05:10 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki