Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 History  





2 Applications  





3 Endotracheal tube  





4 Tracheostomy tube  





5 Tracheal button  





6 See also  





7 References  





8 Further reading  





9 External links  














Tracheal tube






العربية
Deutsch
Ελληνικά
Español
فارسی
Français
Bahasa Indonesia
Italiano
עברית
Nederlands

Norsk bokmål
Polski
Српски / srpski
Suomi
Svenska
Українська
اردو
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 




In other projects  



Wikimedia Commons
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Tracheal tube
ICD-9-CM96.04

[edit on Wikidata]

Atracheal tube is a catheter that is inserted into the trachea for the primary purpose of establishing and maintaining a patent airway and to ensure the adequate exchangeofoxygen and carbon dioxide.

Many different types of tracheal tubes are available, suited for different specific applications:

History[edit]

Portex Medical (England and France) produced the first cuff-less plastic 'Ivory' endotracheal tubes.[1] Ivan Magill later added a cuff (these were glued on by hand to make the famous Blue-line tube copied by many other manufacturers). Maeterlinck GmbH developed the disposable endotracheal tube and produced many design variations, adding the 'Murphy Eye' to their tubes in case of 'accidental' placement of the tube to avoid right bronchial occlusion. David S. Sheridan was one of the manufacturers of the American markets "disposable" plastic tracheal tube now used routinely in surgery. Previously, red rubber (Rusch-Germany) tubes were used, then sterilized for re-use. [2]

Applications[edit]

Tracheal tubes can also be used to deliver oxygen in higher concentrations than found in air, or to administer other gases such as helium, nitric oxide, nitrous oxide, xenon, or certain volatile anesthetic agents such as desflurane, isoflurane, or sevoflurane. Tracheal tubes may also be used as a route for administration of certain medications such as salbutamol, atropine, epinephrine, ipratropium, and lidocaine. Tracheal tubes are commonly used for airway management in the settings of general anesthesia, critical care, mechanical ventilation, and emergency medicine.[3]

Endotracheal tube[edit]

Age Weight (Inner)
diameter
(mm)
Preterm kg 2.5–3.0[4]
0–6 months 3.5 kg 3.0–3.5[4]
6–12 months kg 3.5–4.0[4]
1–3 years 10–12 kg 4.0–4.5[4]
4–7 years 16–18 kg 5.0–5.5[4]
8–10 years 24–30 kg 5.5–6.5[4]
Adult female 7.0–7.5[5]
Adult male 8.0–8.5[5]
A typical cuffed endotracheal tube, constructed of polyvinyl chloride
A Carlens double-lumen endotracheal tube, commonly used for thoracic surgical operations such as VATS lobectomy

Most endotracheal tubes today are constructed of polyvinyl chloride, but specialty tubes constructed of silicone rubber, latex rubber, or stainless steel are also widely available. Most tubes have an inflatable cuff to seal the trachea and bronchial tree against air leakage and aspiration of gastric contents, blood, secretions, and other fluids. Uncuffed tubes are also available, though their use is limited mostly to pediatric patients (in small children, the cricoid cartilage, the narrowest portion of the pediatric airway, often provides an adequate seal for mechanical ventilation).

Types of endotracheal tubes include oral or nasal, cuffed or uncuffed, preformed (e.g. RAE (Ring, Adair, and Elwyn) tube), reinforced tubes, and double-lumen endobronchial tubes. For human use, tubes range in size from 2 to 10.5 mm in internal diameter (ID). The size is chosen based on the patient's body size, with the smaller sizes being used for pediatric and neonatal patients. Tubes larger than 6 mm ID usually have an inflatable cuff. Originally made from red rubber, most modern tubes are made from polyvinyl chloride. Those placed in a laser field may be flexometallic. Robertshaw (and others) developed double-lumen endobronchial tubes for thoracic surgery. These allow single-lung ventilation while the other lung is collapsed to make surgery easier. The deflated lung is re-inflated as surgery finishes to check for fistulas (tears). Another type of endotracheal tube has a small second lumen opening above the inflatable cuff, which can be used for suction of the nasopharngeal area and above the cuff to aid extubation (removal). This allows suctioning of secretions that sit above the cuff which helps reduce the risk of chest infections in long-term intubated patients.

The "armored" endotracheal tubes are cuffed, wire-reinforced, silicone rubber tubes that are quite flexible but yet difficult to compress or kink. This can make them useful for situations in which the trachea is anticipated to remain intubated for a prolonged duration, or if the neck is to remain flexed during surgery. Polyvinyl chloride tubes are relatively stiff in comparison. Preformed tubes (such as the oral and nasal RAE tubes, named after the inventors Ring, Adair and Elwyn) are also widely available for special applications. These may also be constructed of polyvinyl chloride or wire-reinforced silicone rubber. Other tubes (such as the Bivona Fome-Cuf tube) are designed specifically for use in laser surgery in and around the airway. Various types of double-lumen endotracheal (actually, endobronchial) tubes have been developed (Carlens,[6] White, Robertshaw, etc.) for ventilating each lung independently—this is useful during pulmonary and other thoracic operations.

Tracheostomy tube[edit]

Several types of tracheostomy tubes are available, depending on the requirements of the patient, including Shiley, Bivona (a silicon tube with metal rings that are good for airways with damage to the tracheal rings or otherwise not straight), and fenestrated.[7]

Tracheal button[edit]

A tracheal button is generally used in people with severe obstructive sleep apnea, who often wear this device during waking hours and remove it while sleeping to ensure a patent airway and reduce the risk of asphyxiation. Since the tube does not extend far into the trachea, it is easy to breathe and speak with the device in place.

See also[edit]

References[edit]

  1. ^ Dunn, Peter F.; Goulet, Robert L. (2000). "Endotracheal Tubes and Airway Appliances". International Anesthesiology Clinics. 38 (3): 65–94. doi:10.1097/00004311-200007000-00006. ISSN 0020-5907. S2CID 27411412.
  • ^ Hood, R. Maurice; Rush, Clyde E. (March 1962). "LETHAL HAZARDS OF THE MöRCH RESPIRATOR". The Journal of Thoracic and Cardiovascular Surgery. 43 (3): 338–342. doi:10.1016/s0022-5223(20)31610-x. ISSN 0022-5223. PMID 13908743.
  • ^ Edling, Christer (2020-10-28), "Anesthetic Gases", Occupational Hazards in the Health Professions, CRC Press, pp. 121–130, doi:10.1201/9781003068617-6, ISBN 9781003068617, S2CID 243089311, retrieved 2023-05-24
  • ^ a b c d e f "Equipment Sizing Chart". University of Iowa Children's Hospital. Retrieved 2015-11-07.
  • ^ a b Varshney, Manu; Kumar, Rakesh; Sharma, Kavita; Varshney, PreetiG (2011). "Appropriate depth of placement of oral endotracheal tube and its possible determinants in Indian adult patients". Indian Journal of Anaesthesia. 55 (5): 488–93. doi:10.4103/0019-5049.89880. ISSN 0019-5049. PMC 3237149. PMID 22174466.
  • ^ Carlens E (October 1949). "A new flexible double-lumen catheter for bronchospirometry". J Thorac Surg. 18 (5): 742–746. doi:10.1016/S0096-5588(20)31326-X. PMID 18149050.
  • ^ Specification for Tracheostomy Tubes-Pediatric Tracheostomy Tubes, ASTM International, doi:10.1520/f1627, retrieved 2023-05-24
  • Further reading[edit]

    External links[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Tracheal_tube&oldid=1222555927"

    Categories: 
    Airway management
    Medical equipment
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
     



    This page was last edited on 6 May 2024, at 16:39 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki