1 History  





2 Method  





3 Scale  





4 Corrections  





5 See also  





6 Notes and references  














Wedgwood scale






Deutsch
Hrvatski

Português
Русский
Українська
Tiếng Vit
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Josiah Wedgwood

The Wedgwood scale (°W) is an obsolete temperature scale, which was used to measure temperatures above the boiling point of mercury of 356 °C (673 °F). The scale and associated measurement technique were proposed by the English potter Josiah Wedgwood in the 18th century. The measurement was based on the shrinking of clay when heated above red heat, and the shrinking was evaluated by comparing heated and unheated clay cylinders. It was the first standardised pyrometric device. The scale started at 1,077.5 °F (580.8 °C) being 0 °W and had 240 steps of 130 °F (72 °C). Both the origin and the step were later found inaccurate.

History

[edit]

The boiling point of mercury limits the mercury-in-glass thermometer to temperatures below 356 °C, which is too low for many industrial applications such as pottery, glass making and metallurgy.

To solve this problem, n 1782, Wedgwood created an accurately scaled pyrometric device, with details published in the Philosophical Transactions of the Royal Society of London in 1782 (Vol. LXXII, part 2). This led him to be elected a fellow of the Royal Society.[1][2][3][4] [5][6][7]

Method

[edit]
A device for converting the diameter of the annealed clay cylinder into the Wedgwood temperature.

A 0.5-inch-diameter cylinder made from pipe clay was dried at the temperature of boiling water. This would prepare it for heating in the oven in which the temperature was to be measured. During the annealing, sintering (merging) of fine particles resulted in contraction of clay. After cooling, the temperature was evaluated from the diameter difference before and after heating assuming that the contraction is linear with temperature.[8]

To facilitate the temperature calculation, Wedgwood built a device which would directly read the temperature. Two metal bars with scales on them were fixed one above another on a metal plate and inclined at a small angle. The spacing between the bars was 0.5 inches at one end and 0.3 inches at the lower end. The scale was divided into 240 equidistant parts. The unheated piece of clay would fit the 0.5-inch gap giving the zero temperature reading. After annealing, the clay cylinder would shrink and fit somewhere in between the left and right ends of the bars, and the temperature could be read from the scales on the bars.[9][10]

Scale

[edit]

The origin on the Wedgwood scale (0 °W) was set at the onset temperature of red heat, 1,077.5 °F (580.8 °C). The scale had 240 steps of 130 °F (72 °C) and extended up to 32,277 °F (17,914 °C).[8][11] Wedgwood tried to compare his scale with other scales by measuring the expansion of silver as a function of temperature. He also determined the melting points of three metals, namely copper (27 °W or 4,587 °F (2,531 °C)), silver (28 °W or 4,717 °F (2,603 °C)) and gold (32 °W or 5,237 °F (2,892 °C)). All these values are at least 2,500 °F (1,400 °C) too high.[12]

Corrections

[edit]

Louis-Bernard Guyton de Morveau used his pyrometer to evaluate the temperature scale of Wedgwood and came to the conclusion that the starting point should be significantly lower, at 517 °F (269 °C) instead of 1,077.5 °F (580.8 °C), and that the steps should be nearly halved from 130 °F (72 °C) to no more than 62.5 °F (34.7 °C). However, even after this revision the Wedgwood measurements overestimated the melting points of elements.[10]

See also

[edit]

Notes and references

[edit]
  1. ^ "Wedgwood Pyrometer by J. Newman, 1827-56 | Science Museum Group Collection".
  • ^ "Museo Galileo - Wedgwood pyrometer".
  • ^ "Image of wedgwood pyrometer, 1786. By Science & Society Picture Library".
  • ^ "Wedgwood's pyrometer".
  • ^ "Philosophical Transactions of the Royal Society of London. Vol. LXXII. For the Year 1782. Part II". The London Medical Journal. 4 (3): 225–235. 1783. PMC 5545481.
  • ^ Chaldecott, J. A. (1975). "Presidential Address: Josiah Wedgwood (1730–95): Scientist". The British Journal for the History of Science. 8 (1): 1–16. doi:10.1017/s0007087400013674. JSTOR 4025813.
  • ^ "BBC – History – Historic Figures: Josiah Wedgwood (1730–1795)". bbc.co.uk.
  • ^ a b Dictionary (1867). A dictionary of science, literature and art, ed. By W.T. Brande assisted by J. Cauvin. Ed. By W.T. Brande and G.W. Cox.3 vols. pp. 149–150.
  • ^ Justus Liebig (Freiherr) (1854). Handwörterbuch der Reinen und Angewandten Chemie ... (in German). pp. 713–714.
  • ^ a b Natural Philosophy. Volume 2. Popular Introductions to Natural Philosophy. Newton's Optics. Description of Optical Instruments. Thermometer and Pyrometer. With an Explanation of Scientific Terms, and an Index. 1832. pp. 27–30. ISBN 978-0-543-88106-9.
  • ^ Gehler, Johann Samuel Traugott; Littrow, Karl Ludwig (1834). Johann Samuel Traugott Gehler's physikalisches Wörterbuch: Bd., 1. Abth. (1833) N-Pn; 2. Abth. (1834) Po-R. E. B. Schurckert. p. 986.
  • ^ Newcomb, Sally (2009-02-15). The world in a crucible: laboratory practice and geological theory at the beginning of geology. Geological Society of America. ISBN 978-0-8137-2449-2.

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Wedgwood_scale&oldid=1231755456"

    Categories: 
    Obsolete units of measurement
    Scales of temperature
    Science and technology in England
    Hidden categories: 
    CS1 German-language sources (de)
    Articles with short description
    Short description matches Wikidata
     



    This page was last edited on 30 June 2024, at 02:44 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki