Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 History  





2 Present day  





3 References  














Winston Tunnel







Polski
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 





Coordinates: 42°2005N 90°2150W / 42.33472°N 90.36389°W / 42.33472; -90.36389
 

From Wikipedia, the free encyclopedia
 


Winston Tunnel
Overview
LineChicago Great Western Railway
LocationJo Daviess County, 9 miles (14 km) west of Elizabeth, IL
Coordinates42°20′05N 90°21′50W / 42.33472°N 90.36389°W / 42.33472; -90.36389
StatusAbandoned and closed
Operation
Opened1888
Closed1972
Technical
Line length2,493 feet (760 m)
Highest elevation797 feet (243 m) above sea level
Tunnel clearance18.5 feet (5.6 m)
Grade0.92% (rising east)

The Winston Tunnel is a railroad tunnel located 9 miles (14.5 kilometers) west of Elizabeth, Illinois.

The tunnel was completed in 1888 for the Minnesota and Northwestern Railroad, a predecessor to the Chicago Great Western Railway (CGW). The tunnel was located on the CGW main line 152 miles (245 kilometers) west of Chicago in the isolated and hilly Driftless Area of extreme north-western Illinois.

In 1972, four years after the Chicago Great Western was merged into the Chicago and North Western Railway (C&NW), the CGW's largely redundant trackage in the area, including the Winston Tunnel, was abandoned. It was the third longest railroad tunnel in Illinois at 2,493 feet (760 m). Two longer (still active) tunnels are located on the Canadian National (ex-Illinois Central) Edgewood Cutoff Line, the longest being Tunnel #2 near Abbot, Illinois which is 6,994 feet (2,132 m) long.[citation needed]

History[edit]

The newly constructed Minnesota and Northwestern Railroad across northern Illinois used trackage rights on the Illinois Central Railroad between Dubuque, Iowa and Stockton, Illinois in 1886 before construction on its own line through the isolated wilderness could commence. Engineers quickly realized that a tunnel would need to be constructed in order to traverse the rugged landscape. The Sheppard, Winston and Company (for which the tunnel would be named) and more than 350 laborers worked by hand, digging through the silty and unstable shale for nine months starting in the spring of 1887. The work was both strenuous and dangerous, and at least one worker, a thirty-two-year-old Finnish immigrant named John Hill, was killed.[1] When complete, the total cost of the tunnel, $600,000, had exceeded expectations.[2]

The tunnel proved to be a constant nuisance to the Chicago Great Western and its predecessors. Almost immediately, railroad engineers realized that the unstable nature of shale through which the tunnel was bored, ground water seepage, and the isolated location of the tunnel meant repairs would be frequent and costly. The tunnel was originally braced by wooden beams when it opened to rail traffic in January 1888, but these eventually proved inadequate, and were replaced in 1902 by brick and reinforced concrete. Constant deterioration of the supports meant that large-scale reconstruction of the tunnel was needed in 1912, 1918, 1944 and 1947.[3]

The bore was also improperly ventilated at first. A shaft sunk into the top of the tunnel failed to provide enough fresh air, and the crews of the steam engines would often complain of the intense heat and smoke due to the poor air circulation. Piecemeal solutions failed to work, and by 1912 the railroad was forced to install a huge fan, powered by a 310 horsepower (230 kW) diesel motor and staffed by operators day and night, to ventilate the tunnel. The fanhouse, constructed by 1916, was abandoned by the CGW with the acquisition of diesel locomotives by 1947.[4][5]

When the Chicago Great Western was federalized during World War I, a contingent of Illinois National Guardsmen were assigned to protect the tunnel.[6]

The operating nightmares of the tunnel, not to mention the millions of dollars the CGW spent to keep it open, forced the railroad's management to consider many schemes to rid themselves of the burden. In 1909, 1951 and again in 1964 (the same year the North Western and Great Western announced their intentions to merge) the CGW sought engineering proposals to reroute their trackage around the bore, to daylight the tunnel, or to completely rebuild and improve it. To the often cash-strapped Great Western, however, all these plans proved far too expensive.[7]

In the end, the 1968 merger with the Chicago and North Western (C&NW) sealed the Winston Tunnel's fate. The Great Western's main line through northern Illinois closely paralleled the North Western's own line, but through less densely populated and less commercially active areas. The steep grades of the line and the obvious financial burden of the Winston Tunnel also played a role in the decision to completely abandon the Great Western's trackage in the area. The C&NW operated its last train through the tunnel in 1971. Scrappers pulled up the tracks the following year. Upon abandonment, the C&NW placed chain-link fences over each bore of the tunnel to keep squatters and other trespassers out.[8] A 1973 attempt to turn the right-of-way through Jo Daviess County, including the Winston Tunnel, into a rail trail, failed when ownership of the land reverted to nearby property owners.[5]

Present day[edit]

The Winston Tunnel still exists in a very deteriorated condition. Nature has reclaimed the right-of-way; the fan house, unused since the 1940s and damaged by the elements, was demolished in early 2007, and the eastern bore, located on private property, has been almost completely sealed with earth.[citation needed]

The western half was purchased by the Illinois Department of Natural Resources as a "satellite area" of Apple River Canyon State Park. The DNR installed a new steel gate to replace the chain-link fence covering the western bore,[9] and is developing the area with nature trails and other improvements.[10] The tunnel is off-limits to public visitation as it is unsafe, due both to rattlesnakes and the ever-present danger of further collapse.

References[edit]

Notes
  1. ^ Grant 1984, p. 14-5
  • ^ Schweihs 2007, p. 60
  • ^ Finch 1985, pp. 28–29, 52–53
  • ^ Finch 1985, pp. 25–26
  • ^ a b Schweihs 2007, p. 62
  • ^ Grant 1984, p. 89
  • ^ Finch 1985, pp. 29–31
  • ^ Huddleston, Jerry. "The Hole in Stickney's Pocketbook: CGW's Winston Tunnel".
  • ^ Hensal, Jeffrey (October 30, 2003). "Plan of Work: Apple River Canyon State Park" (PDF).
  • ^ "Environmental Reviews Completed" (PDF). The Environmental Reporter. Vol. 14, no. 12. The Illinois Department of Natural Resources. July 1, 2005. Archived from the original (PDF) on June 22, 2006.
  • Sources

    Retrieved from "https://en.wikipedia.org/w/index.php?title=Winston_Tunnel&oldid=1175661228"

    Categories: 
    Chicago Great Western Railway
    Transportation buildings and structures in Jo Daviess County, Illinois
    Railroad tunnels in Illinois
    Tunnels completed in 1888
    Hidden categories: 
    Pages using gadget WikiMiniAtlas
    Articles with short description
    Short description is different from Wikidata
    Coordinates on Wikidata
    All articles with unsourced statements
    Articles with unsourced statements from May 2016
    Articles with unsourced statements from January 2023
     



    This page was last edited on 16 September 2023, at 14:42 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki