Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  



























Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Humans  



1.1  Semi-automated system  







2 Other animals  





3 See also  





4 References  





5 External links  














Blood volume






العربية
Català
Deutsch
Español
Français
Italiano
Nederlands
Português
Українська
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 


















From Wikipedia, the free encyclopedia
 


Blood volume (volemia) is the volumeofblood (blood cells and plasma) in the circulatory system of any individual.

Humans[edit]

A typical adult has a blood volume of approximately 5 liters, with females and males having approximately the same blood percentage by weight (approx 7 to 8%)[1][2] Blood volume is regulated by the kidneys.

Blood volume (BV) can be calculated given the hematocrit (HC; the fraction of blood that is red blood cells) and plasma volume (PV), with the hematocrit being regulated via the blood oxygen content regulator:

Blood volume measurement may be used in people with congestive heart failure, chronic hypertension, kidney failure and critical care.

The use of relative blood volume changes during dialysis is of questionable utility.[3]

Total Blood Volume can be measured manually via the Dual Isotope or Dual Tracer Technique, a classic technique, available since the 1950s.[4] This technique requires double labeling of the blood; that is 2 injections and 2 standards (51Cr-RBC for tagging red blood cells and I-HAS for tagging plasma volume) as well as withdrawing and re-infusing patients with their own blood for blood volume analysis results. This method may take up to 6 hours for accurate results. The blood volume is 70 ml/kg body weight in adult males, 65 ml/kg in adult females and 70-75 ml/kg in children (1 year old and over).[5][6]

Semi-automated system[edit]

Blood volume may also be measured semi-automatically. The BVA-100, a product of Daxor Corporation, is an FDA-cleared diagnostic used at leading medical centers in the United States which consists of an automated well counter interfaced with a computer.[7] It is able to report with 98% accuracy within 60 minutes the Total Blood Volume (TBV), Plasma Volume (PV) and Red Cell Volume (RCV) using the indicator dilution principle, microhematocrit centrifugation and the Ideal Height and Weight Method.[4] The indicator, or tracer, is an I-131 albumin injection. An equal amount of the tracer is injected into a known and unknown volume. Clinically, the unknown volume is the patient's blood volume, with the tracer having been injected into the patient's blood stream and tagged to the blood plasma. Once the tracer is injected a technician takes five blood samples which undergo microhematocrit centrifugation to extrapolate true blood volume at time 0. The concentration of the I-131 in the blood is determined from the blood radioactivity against the standard, which has a known I-131 dilution in a known volume. The unknown volume is inversely proportional to the concentration of the indicator in the known volume; the larger the unknown volume, the lower the tracer concentration, thus the unknown volume can be calculated. The microhematocrit data along with the I-131 indicator data provide a normalized hematocrit number, more accurate than hematocrit or peripheral hematocrit measurements.[8] Measurements are taken 5 times at 6-minute intervals so that the BVA-100 can calculate the albumin transudation time to understand the flux of liquid through capillary membranes.

Blood volumes have also been measured in humans using the non-radioactive, carbon monoxide (CO) rebreathing technique for more than 100 years. With this technique, a small volume of pure CO gas is inhaled and rebreathed for a few minutes. During rebreathing, CO binds to hemoglobin present in red blood cells. Based on the increase in blood CO after the rebreathing period, the volume of blood can be determined through the dilution principle (i.e. similar as the case for radioactive tracer methods). Although CO gas in large volumes is toxic to humans, the volume used to access blood volumes corresponds to what would be inhaled when smoking one cigarette. While researchers typically use custom-made rebreathing circuits, the Detalo Performance from Detalo Health has fully automated the procedure and made the measurement available to a larger group of users.[9]

Other animals[edit]

Animal Blood volume
(ml/kg)[10]
Cat 55 (47-66)
Cow 55 (52-57)[11]
Dog 86 (79-90)
Ferret 75
Gerbil 67
Goat 70
Guinea pig 75 (67-92)
Hamster 78
Horse 76
Human (male) 75
Human (female) 65
Monkey (rhesus) 54
Mouse 79 (78-80)
Pig 65
Rabbit 56 (44-70)
Rat 64 (50-70)
Sheep 60
Marmoset 60-70[12]

The table at right shows circulating blood volumes, given as volume per kilogram, for healthy adults and some animals.[10] However, it can be 15% less in obese and old animals.[10]

See also[edit]

References[edit]

  1. ^ "How much blood is in the human body? What to know". June 2020.
  • ^ Lee, LanNa (1998). Elert, Glenn (ed.). "Volume of blood in a human". The Physics Factbook. Retrieved 2019-03-23.
  • ^ Dasselaar, JJ; van der Sande, FM; Franssen, CF (2012). "Critical evaluation of blood volume measurements during hemodialysis". Blood Purification. 33 (1–3): 177–82. doi:10.1159/000334142. PMID 22269777.
  • ^ a b Yu, Mihae (2011). "A Prospective Randomized Trial Using Blood Volume Analysis in Addition to Pulmonary Artery Catheter, Compared with Pulmonary Catheter Alone, to Guide Shock Resuscitation in Critically Ill Surgical Patients". Shock. 35 (3): 220–228. CiteSeerX 10.1.1.693.1316. doi:10.1097/shk.0b013e3181fc9178. PMID 20926981. S2CID 21290772.
  • ^ "History of Changes for Study: NCT02972294".
  • ^ "Maximum allowable blood loss | Iowa Head and Neck Protocols".
  • ^ Manzone, T. A.; Dam, H. Q.; Soltis, D.; Sagar, V. V. (11 May 2007). "Blood Volume Analysis: A New Technique and New Clinical Interest Reinvigorate a Classic Study". Journal of Nuclear Medicine Technology. 35 (2): 55–63. doi:10.2967/jnmt.106.035972. PMID 17496003.
  • ^ Park, Junki; Puri, Sonika; Mattoo, Aditya; Modersitzki, Frank; Goldfarb, David (2012). "Radioisotope Blood Volume Measurement in Hemodialysis Patients" (PDF).
  • ^ Siebenmann, Christoph; Keiser, Stefanie; Robach, Paul; Lundby, Carsten (29 June 2017). "CORP: The assessment of total hemoglobin mass by carbon monoxide rebreathing". Journal of Applied Physiology. 123 (3): 645–654. doi:10.1152/japplphysiol.00185.2017. ISSN 8750-7587. PMID 28663373.
  • ^ a b c A Compendium of Drugs Used for Laboratory Animal Anesthesia, Analgesia, Tranquilization and Restraint Archived June 6, 2011, at the Wayback Machine at Drexel University College of Medicine. Retrieved April 2011
  • ^ Reynolds, Monica; Plasma and Blood Volume in the Cow Using the T-1824 Hematocrit Method American Journal of Physiology - June 1953 vol. 173 no. 3 421-427 doi:10.1152/ajplegacy.1953.173.3.421
  • ^ Wolfensohn & Lloyd, 2003, Handbook of Laboratory Animal Management and Welfare, 3rd Edition
  • External links[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Blood_volume&oldid=1219247966"

    Categories: 
    Blood
    Mathematics in medicine
    Cardiovascular physiology
    Hidden categories: 
    Webarchive template wayback links
    Articles with short description
    Short description is different from Wikidata
    Articles with GND identifiers
     



    This page was last edited on 16 April 2024, at 16:11 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki