(Top)
 


1 Definition  





2 Properties  





3 Frequency response  





4 Filter design  



4.1  Window design method  





4.2  Least mean square error (MSE) method  







5 Moving average example  





6 See also  





7 Notes  





8 References  














Finite impulse response






Български
Català
Čeština
Dansk
Deutsch
Eesti
Español
فارسی
Français
Galego
Italiano
עברית
Nederlands

Norsk nynorsk
Polski
Português
Русский
Shqip
Simple English
Svenska
Українська

 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 




In other projects  



Wikimedia Commons
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 

(Redirected from FIR filter)

Insignal processing, a finite impulse response (FIR) filter is a filter whose impulse response (or response to any finite length input) is of finite duration, because it settles to zero in finite time. This is in contrast to infinite impulse response (IIR) filters, which may have internal feedback and may continue to respond indefinitely (usually decaying).[citation needed]

The impulse response (that is, the output in response to a Kronecker delta input) of an Nth-order discrete-time FIR filter lasts exactly samples (from first nonzero element through last nonzero element) before it then settles to zero.

FIR filters can be discrete-timeorcontinuous-time, and digitaloranalog.

Definition

[edit]
A direct form discrete-time FIR filter of order N. The top part is an N-stage delay line with N + 1 taps. Each unit delay is a z−1 operator in Z-transform notation.
A depiction of a lattice type F I R filter
A lattice-form discrete-time FIR filter of order N. Each unit delay is a z−1 operator in Z-transform notation.

For a causal discrete-time FIR filter of order N, each value of the output sequence is a weighted sum of the most recent input values:

where:

This computation is also known as discrete convolution.

The in these terms are commonly referred to as taps, based on the structure of a tapped delay line that in many implementations or block diagrams provides the delayed inputs to the multiplication operations. One may speak of a 5th order/6-tap filter, for instance.

The impulse response of the filter as defined is nonzero over a finite duration. Including zeros, the impulse response is the infinite sequence:

If an FIR filter is non-causal, the range of nonzero values in its impulse response can start before , with the defining formula appropriately generalized.

Properties

[edit]

An FIR filter has a number of useful properties which sometimes make it preferable to an infinite impulse response (IIR) filter. FIR filters:

The main disadvantage of FIR filters is that considerably more computation power in a general purpose processor is required compared to an IIR filter with similar sharpness or selectivity, especially when low frequency (relative to the sample rate) cutoffs are needed. However, many digital signal processors provide specialized hardware features to make FIR filters approximately as efficient as IIR for many applications.

Frequency response

[edit]

The filter's effect on the sequence is described in the frequency domain by the convolution theorem:

    and    

where operators and respectively denote the discrete-time Fourier transform (DTFT) and its inverse. Therefore, the complex-valued, multiplicative function is the filter's frequency response. It is defined by a Fourier series:

where the added subscript denotes 2π-periodicity. Here represents frequency in normalized units (radians/sample). The substitution favored by many filter design programs, changes the units of frequency tocycles/sample and the periodicity to 1.[A] When the x[n] sequence has a known sampling-rate, samples/second, the substitution changes the units of frequency tocycles/second (hertz) and the periodicity to The value corresponds to a frequency of Hz cycles/sample, which is the Nyquist frequency.

can also be expressed in terms of the Z-transform of the filter impulse response:

Filter design

[edit]

FIR filters are designed by finding the coefficients and filter order that meet certain specifications, which can be in the time domain (e.g. a matched filter) or the frequency domain (most common). Matched filters perform a cross-correlation between the input signal and a known pulse shape. The FIR convolution is a cross-correlation between the input signal and a time-reversed copy of the impulse response. Therefore, the matched filter's impulse response is "designed" by sampling the known pulse-shape and using those samples in reverse order as the coefficients of the filter.[1]

When a particular frequency response is desired, several different design methods are common:

  1. Window design method
  2. Frequency sampling method
  3. Least MSE (mean square error) method
  4. Parks–McClellan method (also known as the equiripple, optimal, or minimax method). The Remez exchange algorithm is commonly used to find an optimal equiripple set of coefficients. Here the user specifies a desired frequency response, a weighting function for errors from this response, and a filter order N. The algorithm then finds the set of coefficients that minimize the maximum deviation from the ideal. Intuitively, this finds the filter that is as close as possible to the desired response given that only coefficients can be used. This method is particularly easy in practice since at least one text[2] includes a program that takes the desired filter and N, and returns the optimum coefficients.
  5. Equiripple FIR filters can be designed using the DFT algorithms as well.[3] The algorithm is iterative in nature. The DFT of an initial filter design is computed using the FFT algorithm (if an initial estimate is not available, h[n]=delta[n] can be used). In the Fourier domain, or DFT domain, the frequency response is corrected according to the desired specs, and the inverse DFT is then computed. In the time-domain, only the first N coefficients are kept (the other coefficients are set to zero). The process is then repeated iteratively: the DFT is computed once again, correction applied in the frequency domain and so on.

Software packages such as MATLAB, GNU Octave, Scilab, and SciPy provide convenient ways to apply these different methods.

Window design method

[edit]

In the window design method, one first designs an ideal IIR filter and then truncates the infinite impulse response by multiplying it with a finite length window function. The result is a finite impulse response filter whose frequency response is modified from that of the IIR filter. Multiplying the infinite impulse by the window function in the time domain results in the frequency response of the IIR being convolved with the Fourier transform (or DTFT) of the window function. If the window's main lobe is narrow, the composite frequency response remains close to that of the ideal IIR filter.

The ideal response is often rectangular, and the corresponding IIR is a sinc function. The result of the frequency domain convolution is that the edges of the rectangle are tapered, and ripples appear in the passband and stopband. Working backward, one can specify the slope (or width) of the tapered region (transition band) and the height of the ripples, and thereby derive the frequency-domain parameters of an appropriate window function. Continuing backward to an impulse response can be done by iterating a filter design program to find the minimum filter order. Another method is to restrict the solution set to the parametric family of Kaiser windows, which provides closed form relationships between the time-domain and frequency domain parameters. In general, that method will not achieve the minimum possible filter order, but it is particularly convenient for automated applications that require dynamic, on-the-fly, filter design.

The window design method is also advantageous for creating efficient half-band filters, because the corresponding sinc function is zero at every other sample point (except the center one). The product with the window function does not alter the zeros, so almost half of the coefficients of the final impulse response are zero. An appropriate implementation of the FIR calculations can exploit that property to double the filter's efficiency.

Least mean square error (MSE) method

[edit]

Goal:

To design FIR filter in the MSE sense, we minimize the mean square error between the filter we obtained and the desired filter.
, where is sampling frequency, is the spectrum of the filter we obtained, and is the spectrum of the desired filter.

Method:

Given an N-point FIR filter , and .
Step 1: Suppose even symmetric. Then, the discrete time Fourier transform of is defined as
Step 2: Calculate mean square error.
Therefore,
Step 3: Minimize the mean square error by doing partial derivative of MSE with respect to
After organization, we have
Step 4: Change back to the presentation of
and

In addition, we can treat the importance of passband and stopband differently according to our needs by adding a weighted function, Then, the MSE error becomes

Moving average example

[edit]
Block diagram of a simple FIR filter (second-order/3-tap filter in this case, implementing a moving average smoothing filter)
Block diagram of a simple FIR filter (second-order/3-tap filter in this case, implementing a moving average smoothing filter)
Pole–zero diagram
Pole–zero diagram of the example second-order FIR smoothing filter
Magnitude and phase responses of the example second-order FIR smoothing filter
Magnitude and phase responses of the example second-order FIR smoothing filter
Amplitude and phase responses of the example second-order FIR smoothing filter
Amplitude and phase responses of the example second-order FIR smoothing filter

Amoving average filter is a very simple FIR filter. It is sometimes called a boxcar filter, especially when followed by decimation, or a sinc-in-frequency. The filter coefficients, , are found via the following equation:

To provide a more specific example, we select the filter order:

The impulse response of the resulting filter is:

The block diagram on the right shows the second-order moving-average filter discussed below. The transfer function is:

The next figure shows the corresponding pole–zero diagram. Zero frequency (DC) corresponds to (1, 0), positive frequencies advancing counterclockwise around the circle to the Nyquist frequency at (−1, 0). Two poles are located at the origin, and two zeros are located at , .

The frequency response, in terms of normalized frequency ω, is:

The magnitude and phase components of are plotted in the figure. But plots like these can also be generated by doing a discrete Fourier transform (DFT) of the impulse response.[B] And because of symmetry, filter design or viewing software often displays only the [0, π] region. The magnitude plot indicates that the moving-average filter passes low frequencies with a gain near 1 and attenuates high frequencies, and is thus a crude low-pass filter. The phase plot is linear except for discontinuities at the two frequencies where the magnitude goes to zero. The size of the discontinuities is π, representing a sign reversal. They do not affect the property of linear phase, as illustrated in the final figure.

See also

[edit]

Notes

[edit]
  1. ^ An exception is MATLAB, which prefers units of half-cycles/sample = cycles/2-samples, because the Nyquist frequency in those units is 1, a convenient choice for plotting software that displays the interval from 0 to the Nyquist frequency.
  • ^ See § Sampling the DTFT.
  • References

    [edit]
    1. ^ Oppenheim, Alan V., Willsky, Alan S., and Young, Ian T.,1983: Signals and Systems, p. 256 (Englewood Cliffs, New Jersey: Prentice-Hall, Inc.) ISBN 0-13-809731-3
  • ^ Rabiner, Lawrence R., and Gold, Bernard, 1975: Theory and Application of Digital Signal Processing (Englewood Cliffs, New Jersey: Prentice-Hall, Inc.) ISBN 0-13-914101-4
  • ^ A. E. Cetin, O.N. Gerek, Y. Yardimci, "Equiripple FIR filter design by the FFT algorithm," IEEE Signal Processing Magazine, pp. 60–64, March 1997.

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Finite_impulse_response&oldid=1220206717"

    Categories: 
    Digital signal processing
    Filter theory
    Hidden categories: 
    Articles with short description
    Short description matches Wikidata
    All articles with unsourced statements
    Articles with unsourced statements from March 2023
     



    This page was last edited on 22 April 2024, at 12:34 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki