1 Background  





2 Frequency Domain Severity Factor (FDSF)  





3 Time Domain Severity Factor (TDSF)  





4 See also  





5 References  



5.1  Further reading  
















Severity factor






فارسی
Українська
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Aseverity factor is established as a coefficient to assess the dielectric severity supported by a transformer winding considering the incoming transient overvoltage (voltage spike). It determines the safety margin regarding to the standard acceptance tests either in the frequencyortime domain.

Severity factors are a newly concept for analyzing the dielectric severity supported along transformer windings when a transformer is submitted to a non-standardized transient voltage waveform induced from the power system.

Two are the new factors considered for evaluating the severity supported by the insulation windings both in factory and in service. One factor is called Time Domain Severity Factor (TDSF) and another one is the Frequency Domain Severity Factor (FDSF).

Background[edit]

One first approach to the concept of severity factor was made by Malewski et al.[1] Later, Asano et al. applied the Malewski's idea for further analysis but including the concept of Energy Spectral Density (ESD) associated to the transient voltage wave.[2] A step forward was given by Rocha et al., whom introduced a new coefficient called Frequency Domain Severity Factor (FDSF).[3][4] For those situations where an internal assessment is necessary a new coefficient named Time Domain Severity Factor (TDSF) was proposed by Casimiro Alvarez-Mariño & Xose M. Lopez-Fernandez.[4][5][6]

Frequency Domain Severity Factor (FDSF)[edit]

The FDSF is calculated at transformer terminals and it is mathematically defined as

where ω is the angular frequency, ESDnoStd(ω) is the maximum energy spectral density of the input no-standard transient voltage applied at transformer terminals and ESDenvol(ω) is the energy spectral density envelope for all standards dielectric tests at terminals.

Time Domain Severity Factor (TDSF)[edit]

The TDSF gives further detailed information on the severity supported by the transformer windings due to the transient event coming from the power system, regarding to the internal transient response due to dielectric tests in the time domain. The mathematical expression of this factor is

where ∆VnoStd(i) is the maximum voltage drop along the ith dielectric path due to the no-standard transient events and ∆Venvol(i) is the maximum voltage drop along the same ith dielectric path for all standards dielectric tests.

See also[edit]

References[edit]

  1. ^ R. Malewski, J. Douville, L. Lavallee, "Measurement of Switching Transients in 735 kV Substations and Assessment of their Severity for Transformer Insulation," IEEE Transactions on Power Delivery, vol.3, no.4, pp.1380-1390, Oct. 1988.
  • ^ Asano, R., Rocha, A., Bastos, G. M., “Electrical Transient Interaction Between Transformers and the Power System”, CIGRÉ A2-D1 Colloquium, Brugge, Belgium, October 2007.
  • ^ A. C. O. Rocha, “Electrical Transient Interaction Between Transformers and the Power Systems”, CIGRÉ Session 2008, pp. 1-10, Paris France, August 2008.
  • ^ a b Joint Working Group SC A2 CIGRÉ, "Electrical Transient Interaction between Transformers and Power Systems Archived 2014-11-29 at the Wayback Machine", Technical Brochure JWGA2/C439, Part-1 Expertise&Part-2 Case Studies, April 2014
  • ^ Álvarez-Mariño, Casimiro; Lopez-Fernandez, Xose M.; Jacomo Ramos, Antonio J.M.; Castro Lopes, Ricardo A.F.; Miguel Duarte Couto, José (2012). "Time domain severity factor (TDSF)". COMPEL - the International Journal for Computation and Mathematics in Electrical and Electronic Engineering. 31 (2): 670–681. doi:10.1108/03321641211200644.
  • ^ Xose m. Lopez-Fernandez and Casimiro Alvarez-Mariño, "Iknduced Transient Voltage Performance Between Transformers and VCB. Severity Factors and Case Studies,"IEEE Transactions on Power Delivery, Issue 99., April 2015.
  • Further reading[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Severity_factor&oldid=1221459214"

    Category: 
    Electric transformers
    Hidden categories: 
    Webarchive template wayback links
    Articles with short description
    Short description with empty Wikidata description
     



    This page was last edited on 30 April 2024, at 01:53 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki