(Top)
 


1 Procedure  





2 Separation process and principle  



2.1  Solvent choice  







3 Analysis  





4 Plate production  





5 Applications  



5.1  Reaction monitoring and characterization  





5.2  Purity and purification  







6 See also  





7 References  





8 Bibliography  














Thin-layer chromatography






العربية
Bosanski
Català
Čeština
Deutsch
Eesti
Ελληνικά
Español
فارسی
Français
Galego

ि
Hrvatski
Bahasa Indonesia
Italiano
Македонски
Nederlands

Norsk bokmål
Norsk nynorsk
Polski
Português
Română
Русский
Simple English
Slovenčina
Slovenščina
Српски / srpski
Suomi
Svenska
Українська
Tiếng Vit

 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 




In other projects  



Wikimedia Commons
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Thin-layer chromatography
Separation of black ink on a TLC plate
AcronymTLC
ClassificationChromatography
Other techniques
Related
  • Paper chromatography
  • Agarose gel electrophoresis
  • SDS-PAGE
  • Thin-layer chromatography (TLC) is a chromatography technique that separates components in non-volatile mixtures.[1]

    It is performed on a TLC plate made up of a non-reactive solid coated with a thin layer of adsorbent material.[2] This is called the stationary phase.[2] The sample is deposited on the plate, which is eluted with a solvent or solvent mixture known as the mobile phase (oreluent).[3] This solvent then moves up the plate via capillary action.[4] As with all chromatography, some compounds are more attracted to the mobile phase, while others are more attracted to the stationary phase.[5] Therefore, different compounds move up the TLC plate at different speeds and become separated.[6] To visualize colourless compounds, the plate is viewed under UV light or is stained.[7] Testing different stationary and mobile phases is often necessary to obtain well-defined and separated spots.[citation needed]

    TLC is quick, simple, and gives high sensitivity for a relatively low cost.[5] It can monitor reaction progress, identify compounds in a mixture, determine purity, or purify small amounts of compound.[5]

    Procedure

    [edit]

    The process for TLC is similar to paper chromatography but provides faster runs, better separations, and the choice between different stationary phases.[5] Plates can be labelled before or after the chromatography process with a pencil or other implement that will not interfere with the process.[8]

    There are four main stages to running a thin-layer chromatography plate:[3][8]

    Plate preparation: Using a capillary tube, a small amount of a concentrated solution of the sample is deposited near the bottom edge of a TLC plate. The solvent is allowed to completely evaporate before the next step. A vacuum chamber may be necessary for non-volatile solvents. To make sure there is sufficient compound to obtain a visible result, the spotting procedure can be repeated. Depending on the application, multiple different samples may be placed in a row the same distance from the bottom edge; each sample will move up the plate in its own "lane."

    TLC of three amino acids and a sample (left) with an English translation (right)

    Development chamber preparation: The development solvent or solvent mixture is placed into a transparent container (separation/development chamber) to a depth of less than 1 centimetre. A strip of filter paper (aka "wick") is also placed along the container wall. This filter paper should touch the solvent and almost reach the top of the container. The container is covered with a lid and the solvent vapors are allowed to saturate the atmosphere of the container. Failure to do so results in poor separation and non-reproducible results.

    Development: The TLC plate is placed in the container such that the sample spot(s) are not submerged into the mobile phase. The container is covered to prevent solvent evaporation. The solvent migrates up the plate by capillary action, meets the sample mixture, and carries it up the plate (elutes the sample). The plate is removed from the container before the solvent reaches the top of the plate; otherwise, the results will be misleading. The solvent front, the highest mark the solvent has travelled along the plate, is marked.

    Visualization: The solvent evaporates from the plate. Visualization methods include UV light, staining, and many more.

    Separation process and principle

    [edit]

    The separation of compounds is due to the differences in their attraction to the stationary phase and because of differences in solubility in the solvent.[9] As a result, the compounds and the mobile phase compete for binding sites on the stationary phase.[9] Different compounds in the sample mixture travel at different rates due to the differences in their partition coefficients.[10] Different solvents, or different solvent mixtures, gives different separation.[5] The retardation factor (Rf), or retention factor, quantifies the results. It is the distance traveled by a given substance divided by the distance traveled by the mobile phase.[citation needed]

    Development of a TLC plate. Spots that appear purple separate into red spots and blue spots.

    Innormal-phase TLC, the stationary phase is polar. Silica gel is very common in normal-phase TLC. More polar compounds in a sample mixture interact more strongly with the polar stationary phase.[citation needed] As a result, more-polar compounds move less (resulting in smaller Rf) while less-polar compounds move higher up the plate (higher Rf).[10] A more-polar mobile phase also binds more strongly to the plate, competing more with the compound for binding sites; a more-polar mobile phase also dissolves polar compounds more.[10] As such, all compounds on the TLC plate move higher up the plate in polar solvent mixtures.[citation needed] "Strong" solvents move compounds higher up the plate, whereas "weak" solvents move them less.[11]

    If the stationary phase is non-polar, like C18-functionalized silica plates, it is called reverse-phase TLC. In this case, non-polar compounds move less and polar compounds move more.[citation needed] The solvent mixture will also be much more polar than in normal-phase TLC.[11]

    Solvent choice

    [edit]

    Aneluotropic series, which orders solvents by how much they move compounds, can help in selecting a mobile phase.[5] Solvents are also divided into solvent selectivity groups.[5][12] Using solvents with different elution strengths or different selectivity groups can often give very different results.[5][12] While single-solvent mobile phases can sometimes give good separation, some cases may require solvent mixtures.[13]

    In normal-phase TLC, the most common solvent mixtures include ethyl acetate/hexanes (EtOAc/Hex) for less-polar compounds and methanol/dichloromethane (MeOH/DCM) for more polar compounds.[14] Different solvent mixtures and solvent ratios can help give better separation.[15] In reverse-phase TLC, solvent mixtures are typically water with a less-polar solvent: Typical choices are water with tetrahydrofuran (THF), acetonitrile (ACN), or methanol.[14]

    Analysis

    [edit]
    TLC plate visualised with UV-light

    As the chemicals being separated may be colourless, several methods exist to visualise the spots:

    Plate production

    [edit]

    TLC plates are usually commercially available, with standard particle size ranges to improve reproducibility.[4] They are prepared by mixing the adsorbent, such as silica gel, with a small amount of inert binder like calcium sulfate (gypsum) and water.[18] This mixture is spread as a thick slurry on an unreactive carrier sheet, usually glass, thick aluminum foil, or plastic. The resultant plate is dried and activated by heating in an oven for thirty minutes at 110 °C.[18] The thickness of the absorbent layer is typically around 0.1–0.25 mm for analytical purposes and around 0.5–2.0 mm for preparative TLC.[19] Other adsorbent coatings include aluminium oxide (alumina), or cellulose.[18]

    Applications

    [edit]

    Reaction monitoring and characterization

    [edit]

    TLC is a useful tool for reaction monitoring.[15] For this, the plate normally contains a spot of starting material, a spot from the reaction mixture, and a co-spot (or cross-spot) containing both.[4][14] The analysis will show if the starting material disappeared and if any new products appeared.[14] This provides a quick and easy way to estimate how far a reaction has proceeded. In one study, TLC has been applied in the screening of organic reactions.[20] The researchers react an alcohol and a catalyst directly in the co-spot of a TLC plate before developing it. This provides quick and easy small-scale testing of different reagents.

    TLC for reaction monitoring and choosing a purification solvent mixture (left)TLC from the resulting flash column chromatography (right)

    Compound characterization with TLC is also possible[citation needed] and is similar to reaction monitoring. However, rather than spotting with starting material and reaction mixture, it is with an unknown and a known compound. They may be the same compound if both spots have the same Rf and look the same under the chosen visualization method.[citation needed] However, co-elution complicates both reaction monitoring and characterization. This is because different compounds will move to the same spot on the plate. In such cases, different solvent mixtures may provide better separation.[21]

    Purity and purification

    [edit]

    TLC helps show the purity of a sample.[citation needed] A pure sample should only contain one spot by TLC. TLC is also useful for small-scale purification.[22] Because the separated compounds will be on different areas of the plate, a scientist can scrape off the stationary phase particles containing the desired compound and dissolve them into an appropriate solvent.[22] Once all the compound dissolves in the solvent, they filter out the silica particles, then evaporate the solvent to isolate the product. Big preparative TLC plates with thick silica gel coatings can separate more than 100 mg of material.[22]

    For larger-scale purification and isolation, TLC is useful to quickly test solvent mixtures before running flash column chromatography on a large batch of impure material.[13][23] A compound elutes from a column when the amount of solvent collected is equal to 1/Rf.[24] The eluent from flash column chromatography gets collected across several containers (for example, test tubes) called fractions. TLC helps show which fractions contain impurities and which contain pure compound.[citation needed]

    Furthermore, two-dimensional TLC[4] can help check if a compound is stable on a particular stationary phase. This test requires two runs on a square-shaped TLC plate. The plate is rotated by 90º before the second run. If the target compound appears on the diagonal of the square, it is stable on the chosen stationary phase. Otherwise, it is decomposing on the plate. If this is the case, an alternative stationary phase may prevent this decomposition.[25]

    TLC is also an analytical method for the direct separation of enantiomers and the control of enantiomeric purity, e.g. active pharmaceutical ingredients (APIs) that are chiral.[26]

    See also

    [edit]

    References

    [edit]
    1. ^ Harry W. Lewis & Christopher J. Moody (13 Jun 1989). Experimental Organic Chemistry: Principles and Practice (Illustrated ed.). WileyBlackwell. pp. 159–173. ISBN 9780632020171.
  • ^ a b Zhang, Meizhen; Yu, Qian; Guo, Jiaqi; Wu, Bo; Kong, Xianming (2022-11-28). "Review of Thin-Layer Chromatography Tandem with Surface-Enhanced Raman Spectroscopy for Detection of Analytes in Mixture Samples". Biosensors. 12 (11): 937. doi:10.3390/bios12110937. ISSN 2079-6374. PMC 9687685. PMID 36354446.
  • ^ a b Silver, Jack (2020-12-08). "Let Us Teach Proper Thin Layer Chromatography Technique!". Journal of Chemical Education. 97 (12): 4217–4219. Bibcode:2020JChEd..97.4217S. doi:10.1021/acs.jchemed.0c00437. ISSN 0021-9584. S2CID 226349471.
  • ^ a b c d e f g Stahl, Egon (1969), Stahl, Egon (ed.), "Apparatus and General Techniques in TLC", Thin-Layer Chromatography: A Laboratory Handbook, Berlin, Heidelberg: Springer, pp. 52–86, doi:10.1007/978-3-642-88488-7_3, ISBN 978-3-642-88488-7, retrieved 2023-03-29
  • ^ a b c d e f g h Santiago, Marina; Strobel, Scott (2013-01-01), "Chapter Twenty-Four - Thin Layer Chromatography", in Lorsch, Jon (ed.), Cell, Lipid and Carbohydrate, Methods in Enzymology, vol. 533, Academic Press, pp. 303–324, doi:10.1016/b978-0-12-420067-8.00024-6, ISBN 978-0-12-420067-8, PMID 24182936, retrieved 2023-03-29
  • ^ A.I. Vogel; A.R. Tatchell; B.S. Furnis; A.J. Hannaford & P.W.G. Smith (1989). Vogel's Textbook of Practical Organic Chemistry (5th ed.). Longman Scientific & Technical. ISBN 978-0-582-46236-6.
  • ^ a b Jork, H., Funk, W., Fischer, W., Wimmer, H. (1990): Thin-Layer Chromatography: Reagents and Detection Methods, Volume 1a, VCH, Weinheim, ISBN 3-527-278834
  • ^ a b Thin Layer Chromatography: How To http://www.reachdevices.com/TLC.html
  • ^ a b Reich, E.; Schibli A. (2007). High-performance thin-layer chromatography for the analysis of medicinal plants (Illustrated ed.). New York: Thieme. ISBN 978-3-13-141601-8.
  • ^ a b c Thin Layer Chromatography (TLC): Principle with animation
  • ^ a b Dolan, John W. (31 May 2006). "The Power of Mobile Phase Strength". LCGC North America. LCGC North America-06-01-2006. 24 (6): 570–578. Retrieved 30 March 2023.
  • ^ a b Johnson, Andrew R.; Vitha, Mark F. (2011-01-28). "Chromatographic selectivity triangles". Journal of Chromatography A. EDITORS' CHOICE V. 1218 (4): 556–586. doi:10.1016/j.chroma.2010.09.046. ISSN 0021-9673. PMID 21067756.
  • ^ a b Snyder, Lloyd R.; Kirkland, Joseph J.; Dolan, John W. (2009-11-11). Introduction to Modern Liquid Chromatography. Hoboken, NJ, USA: John Wiley & Sons, Inc. doi:10.1002/9780470508183.app1. ISBN 978-0-470-50818-3.
  • ^ a b c d "SiliaPlate - TLC Practical Guide". SiliCycle. March 28, 2023.
  • ^ a b Dickson, Hamilton; Kittredge, Kevin W.; Sarquis, Arlyne M. (1 July 2004). "Thin-Layer Chromatography: The "Eyes" of the Organic Chemist". Journal of Chemical Education. 81 (7): 1023. Bibcode:2004JChEd..81.1023D. doi:10.1021/ed081p1023. ISSN 0021-9584.
  • ^ Thin Layer Chromatography stains http://www.reachdevices.com/TLC_stains.html
  • ^ Jork, H., Funk, W., Fischer, W., Wimmer, H. (1994): Thin-Layer Chromatography: Reagents and Detection Methods, Volume 1b, VCH, Weinheim
  • ^ a b c O. Kaynar; Y. Berktas (2010-12-01). "How To Choose The Right Plate For Thin-Layer Chromatography?". Reviews in Analytical Chemistry. 29 (3–4): 129–148. doi:10.1515/REVAC.2010.29.3-4.129. ISSN 2191-0189. S2CID 94158318.
  • ^ Tables showing the thickness value of commercial regular and preparative Thin Layer Chromatography plates
  • ^ TLC plates as a convenient platform for solvent-free reactions Jonathan M. Stoddard, Lien Nguyen, Hector Mata-Chavez and Kelly Nguyen Chem. Commun., 2007, 1240–1241, doi:10.1039/b616311d
  • ^ Bickler, Bob (22 November 2022). "Why is Solvent Evaluation by TLC Important for Good Flash Chromatography Results?". Biotage. Retrieved 1 April 2022.
  • ^ a b c Wing, R. E.; Bemiller, J. N. (1972-01-01), Whistler, Roy L.; BeMiller, James N. (eds.), "[8] - Preparative Thin-Layer Chromatography", General Carbohydrate Method, Academic Press, pp. 60–64, doi:10.1016/b978-0-12-746206-6.50015-1, ISBN 978-0-12-746206-6, retrieved 2023-04-01
  • ^ Bickler, Bob (13 November 2020). "Invest 10 minutes on TLC and save a day of grief". Retrieved 30 March 2023.
  • ^ Fair, Justin D.; Kormos, Chad M. (2008-11-21). "Flash column chromatograms estimated from thin-layer chromatography data". Journal of Chromatography A. 1211 (1): 49–54. doi:10.1016/j.chroma.2008.09.085. ISSN 0021-9673. PMID 18849041.
  • ^ "Thin Layer Chromatography: A Complete Guide to TLC". Chemistry Hall. 2020-01-02. Retrieved 2020-01-30.
  • ^ Bhushan, R.; Tanwar, S. J. Chromatogr. A 2010, 1217, 1395–1398. (doi:10.1016/j.chroma.2009.12.071)
  • Bibliography

    [edit]
    • F. Geiss (1987): Fundamentals of thin layer chromatography planar chromatography, Heidelberg, Hüthig, ISBN 3-7785-0854-7
  • Justus G. Kirchner (1978): Thin-layer chromatography, 2nd edition, Wiley
  • Joseph Sherma, Bernard Fried (1991): Handbook of Thin-Layer Chromatography (= Chromatographic Science. Bd. 55). Marcel Dekker, New York NY, ISBN 0-8247-8335-2.
  • Elke Hahn-Deinstorp: Applied Thin-Layer Chromatography. Best Practice and Avoidance of Mistakes. Wiley-VCH, Weinheim u. a. 2000, ISBN 3-527-29839-8

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Thin-layer_chromatography&oldid=1233494966"

    Categories: 
    Chromatography
    Laboratory techniques
    Hidden categories: 
    Articles with short description
    Short description is different from Wikidata
    All articles with unsourced statements
    Articles with unsourced statements from April 2023
    Articles with GND identifiers
    Articles with J9U identifiers
    Articles with LCCN identifiers
    Articles with NKC identifiers
     



    This page was last edited on 9 July 2024, at 11:05 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki