1 References  














Electrogravimetry






العربية
Deutsch
Español
Français
Italiano
Қазақша
Nederlands
Српски / srpski
Українська
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 




In other projects  



Wikimedia Commons
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


Electrogravimetry apparatus

Electrogravimetry is a method used to separate and quantify ions of a substance, usually a metal. In this process, the analyte solution is electrolyzed. Electrochemical reduction causes the analyte to be deposited on the cathode. The mass of the cathode is determined before and after the experiment, and the difference is used to calculate the mass of analyte in the original solution. Controlling the potential of the electrode is important to ensure that only the metal being analyzed will be deposited on the electrode.

The process is similar to electroplating.

The phenomenon of polarization exerts a back EMF in electrolysis, which reduces the actual EMF of the cell. Thus electrolysis of an electrolyte is possible only when this back EMF is overcome. If two separated platinum electrodes are placed in a dilute solution of copper sulfate and if a source of potential is applied, no appreciable current will flow through the system, until some minimum potential is applied after which the current will increase as the applied potential increases. The applied voltage which is just sufficient to overcome the back EMF due to polarization and also to bring about the electrolysis of an electrolyte without any hindrance is known as decomposition potential.

The decomposition potential Ed is composed of various potentials and is given by:

Ea (min)= Ed= Eb+ Es+ Ev

where:

The origins of electrogravimetry date back to the 19th century, when Oliver Wilcott Gibbs, an American chemist, studied the electrolytic precipitation of copper and nickel. This procedure was the first of its kind until Carl Luckow did similar research on electric metal analysis. Today, these two are credited with the invention of the electrogravimetry, known at the time as “electrochemical analysis,” “electroanalysis,” or “electrolytic analysis”.[1]

All methods of electrogravimetry involve a traditional quartz crystal microbalance (QCM) system in which a sensor is used from an AT cut quartz crystal[clarification needed]. The groundwork of the QCM is built upon the notion that any mass delivered on the quartz electrode's interfacial region can be detected through the resonating frequency of the vibrating quartz crystal. While most vibrational modes occurring in the AT cut quartz are negligible, the vibration mode is known as thickness shear mode.[2] These vibrations are extremely sensitive, which permits accurate detection of atomic interactions near the sensor, allowing these techniques to be used in analytical chemistry [further explanation needed].

Through combining the techniques of QCM with classic electrochemical techniques, the electrochemical quartz crystal microbalance (EQCM) was created. EQCM is a new device used to perform the process of electrogravimetry. This device employs a high frequency acoustic wave generated by a piezoelectric resonator to store and dissipate energy infused into the device's interfacial region.[3]

Electrogravimetry has been useful in polymer studies, copper electrodeposition, gold oxidation in an acidic medium, and passivity of iron in a sulfuric medium, as well as Ionic insertion in WO3.[4]

References

[edit]
  1. ^ Lubert, Karl-Heinz; Kalcher, Kurt (2010). "History of Electroanalytical Methods". Electroanalysis. 22 (17–18). John Wiley & Sons, Inc: 1937–1946. doi:10.1002/elan.201000087. Retrieved 9 April 2021.
  • ^ Torres, Róbinson; Arnau, Antonio; Perrot, Hubert. "ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY I: TECHNIQUE FUNDAMENTALS" (PDF). Universidad EIA. Retrieved 9 April 2021.
  • ^ Hillman, Robert (2011). "The EQCM: electrogravimetry with a light touch". Journal of Solid State Electrochemistry. 15 (7–8). Springer Nature Switzerland AG: 1647–1660. doi:10.1007/s10008-011-1371-2. S2CID 97029963. Retrieved 9 April 2021.
  • ^ Gabrielli, C.; Keddam, M.; Nadi, N.; Perrot, H. "Ions and solvent transport across conducting polymers investigated by ac electrogravimetry. Application to polyaniline". Elsevier. doi:10.1002/elan.201000087. Retrieved 9 April 2021.

  • t
  • e

  • Retrieved from "https://en.wikipedia.org/w/index.php?title=Electrogravimetry&oldid=1183375382"

    Categories: 
    Electroanalytical methods
    Analytical chemistry stubs
    Hidden categories: 
    Articles with short description
    Short description is different from Wikidata
    Wikipedia articles needing clarification from April 2021
    Articles with GND identifiers
    All stub articles
     



    This page was last edited on 3 November 2023, at 22:31 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki