1 Classification by target parameter  



1.1  Vital parameters  







2 Medical monitor  



2.1  Components  



2.1.1  Sensor  





2.1.2  Translating component  





2.1.3  Display device  





2.1.4  Communication links  





2.1.5  Other components  







2.2  Mobile appliances  







3 Interpretation of monitored parameters  



3.1  Change in status versus test variability  





3.2  Delta check  







4 Techniques in development  



4.1  Examples and applications  





4.2  Minimum standards of monitoring  





4.3  Essential Monitoring  







5 See also  





6 References  





7 Further reading  





8 External links  














Monitoring (medicine)






العربية
Català
Español
فارسی


Русский
Українська
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 




In other projects  



Wikimedia Commons
 


















From Wikipedia, the free encyclopedia
 


Display device of a medical monitor as used in anesthesia
A patient of an intensive care unit in a German hospital in 2015, with a monitoring screen displaying a graphical electrocardiogram, the heart rate and blood pressure all in real time

In medicine, monitoring is the observation of a disease, condition or one or several medical parameters over time.

It can be performed by continuously measuring certain parameters by using a medical monitor (for example, by continuously measuring vital signs by a bedside monitor), and/or by repeatedly performing medical tests (such as blood glucose monitoring with a glucose meter in people with diabetes mellitus).

Transmitting data from a monitor to a distant monitoring station is known as telemetryorbiotelemetry.

Classification by target parameter[edit]

Monitoring can be classified by the target of interest, including:

Vital parameters[edit]

Ananesthetic machine with integrated systems for monitoring of several vital parameters, including blood pressure and heart rate

Monitoring of vital parameters can include several of the ones mentioned above, and most commonly include at least blood pressure and heart rate, and preferably also pulse oximetry and respiratory rate. Multimodal monitors that simultaneously measure and display the relevant vital parameters are commonly integrated into the bedside monitors in critical care units, and the anesthetic machinesinoperating rooms. These allow for continuous monitoring of a patient, with medical staff being continuously informed of the changes in general condition of a patient. Some monitors can even warn of pending fatal cardiac conditions before visible signs are noticeable to clinical staff, such as atrial fibrillationorpremature ventricular contraction (PVC).

Medical monitor[edit]

Amedical monitororphysiological monitor is a medical device used for monitoring. It can consist of one or more sensors, processing components, display devices (which are sometimes in themselves called "monitors"), as well as communication links for displaying or recording the results elsewhere through a monitoring network.[citation needed]

Components[edit]

Sensor[edit]

Sensors of medical monitors include biosensors and mechanical sensors. For example, photodiode is used in pulse oximetry, Pressure sensor used in Non Invasive bood pressure measurement.

Translating component[edit]

The translating component of medical monitors is responsible for converting the signals from the sensors to a format that can be shown on the display device or transferred to an external display or recording device.

Display device[edit]

Physiological data are displayed continuously on a CRT, LEDorLCD screen as data channels along the time axis. They may be accompanied by numerical readouts of computed parameters on the original data, such as maximum, minimum and average values, pulse and respiratory frequencies, and so on.[citation needed]

Besides the tracings of physiological parameters along time (X axis), digital medical displays have automated numeric readouts of the peak and/or average parameters displayed on the screen.

Modern medical display devices commonly use digital signal processing (DSP), which has the advantages of miniaturization, portability, and multi-parameter displays that can track many different vital signs at once.[citation needed]

Old analog patient displays, in contrast, were based on oscilloscopes, and had one channel only, usually reserved for electrocardiographic monitoring (ECG). Therefore, medical monitors tended to be highly specialized. One monitor would track a patient's blood pressure, while another would measure pulse oximetry, another the ECG. Later analog models had a second or third channel displayed on the same screen, usually to monitor respiration movements and blood pressure. These machines were widely used and saved many lives, but they had several restrictions, including sensitivity to electrical interference, base level fluctuations and absence of numeric readouts and alarms.[citation needed]

Communication links[edit]

Several models of multi-parameter monitors are networkable, i.e., they can send their output to a central ICU monitoring station, where a single staff member can observe and respond to several bedside monitors simultaneously. Ambulatory telemetry can also be achieved by portable, battery-operated models which are carried by the patient and which transmit their data via a wireless data connection.

Digital monitoring has created the possibility, which is being fully developed, of integrating the physiological data from the patient monitoring networks into the emerging hospital electronic health record and digital charting systems, using appropriate health care standards which have been developed for this purpose by organizations such as IEEE and HL7. This newer method of charting patient data reduces the likelihood of human documentation error and will eventually reduce overall paper consumption. In addition, automated ECG interpretation incorporates diagnostic codes automatically into the charts. Medical monitor's embedded software can take care of the data coding according to these standards and send messages to the medical records application, which decodes them and incorporates the data into the adequate fields.

Long-distance connectivity can avail for telemedicine, which involves provision of clinical health care at a distance.

Other components[edit]

A medical monitor can also have the function to produce an alarm (such as using audible signals) to alert the staff when certain criteria are set, such as when some parameter exceeds of falls the level limits.

Mobile appliances[edit]

An entirely new scope is opened with mobile carried monitors, even such in sub-skin carriage. This class of monitors delivers information gathered in body-area networking (BAN) to e.g. smart phones and implemented autonomous agents.

Interpretation of monitored parameters[edit]

Monitoring of clinical parameters is primarily intended to detect changes (or absence of changes) in the clinical status of an individual. For example, the parameter of oxygen saturation is usually monitored to detect changes in respiratory capability of an individual.

Change in status versus test variability[edit]

When monitoring a clinical parameters, differences between test results (or values of a continuously monitored parameter after a time interval) can reflect either (or both) an actual change in the status of the condition or a test-retest variability of the test method.

In practice, the possibility that a difference is due to test-retest variability can almost certainly be excluded if the difference is larger than a predefined "critical difference". This "critical difference" (CD) is calculated as:[2]

, where:[2]

For example, if a patient has a hemoglobin level of 100 g/L, the analytical variation (CVa) is 1.8% and the intra-individual variability CVi is 2.2%, then the critical difference is 8.1 g/L. Thus, for changes of less than 8 g/L since a previous test, the possibility that the change is completely caused by test-retest variability may need to be considered in addition to considering effects of, for example, diseases or treatments.

Critical differences for some blood tests[2]
Sodium 3%
Potassium 14%
Chloride 4%
Urea 30%
Creatinine 14%
Calcium 5%
Albumin 8%
Fasting glucose 15%
Amylase 30%
Carcinoembryonic antigen 69%
C-reactive protein 43%[3]
Glycated hemoglobin 21%
Hemoglobin 8%
Erythrocytes 10%
Leukocytes 32%
Platelets 25%
Unless otherwise specified, then reference for critical values is Fraser 1989[2]

Critical differences for other tests include early morning urinary albumin concentration, with a critical difference of 40%.[2]

Delta check[edit]

In a clinical laboratory, a delta check is a laboratory quality control method that compares a current test result with previous test results of the same person, and detects whether there is a substantial difference, as can be defined as a critical difference as per previous section, or defined by other pre-defined criteria. If the difference exceeds the pre-defined criteria, the result is reported only after manual confirmation by laboratory personnel, in order to exclude a laboratory error as a cause of the difference.[4] In order to flag samples as deviating from previously, the exact cutoff values are chosen to give a balance between sensitivity and the risk of being overwhelmed by false-positive flags.[5] This balance, in turn, depends on the different kinds of clinical situations where the cutoffs are used, and hence, different cutoffs are often used at different departments even in the same hospital.[5]

Techniques in development[edit]

The development of new techniques for monitoring is an advanced and developing field in smart medicine, biomedical-aided integrative medicine, alternative medicine, self-tailored preventive medicine and predictive medicine that emphasizes monitoring of comprehensive medical data of patients, people at risk and healthy people using advanced, smart, minimally invasive biomedical devices, biosensors, lab-on-a-chip (in the future nanomedicine[6][7] devices like nanorobots) and advanced computerized medical diagnosis and early warning tools over a short clinical interview and drug prescription.

Asbiomedical research, nanotechnology and nutrigenomics advances, realizing the human body's self-healing capabilities and the growing awareness of the limitations of medical intervention by chemical drugs-only approach of old school medical treatment, new researches that shows the enormous damage medications can cause,[8][9] researchers are working to fulfill the need for a comprehensive further study and personal continuous clinical monitoring of health conditions while keeping legacy medical intervention as a last resort.

In many medical problems, drugs offer temporary relief of symptoms while the root of a medical problem remains unknown without enough data of all our biological systems[10] . Our body is equipped with sub-systems for the purpose of maintaining balance and self healing functions. Intervention without sufficient data might damage those healing sub systems.[10] Monitoring medicine fills the gap to prevent diagnosis errors and can assist in future medical research by analyzing all data of many patients.

Given Imaging Capsule endoscopy

Examples and applications[edit]

The development cycle in medicine is extremely long, up to 20 years, because of the need for U.S. Food and Drug Administration (FDA) approvals, therefore many of monitoring medicine solutions are not available today in conventional medicine.

The PASCAL Dynamic Contour Tonometer. A monitor for detection of increased intraocular pressure.
Blood glucose monitoring
In vivo blood glucose monitoring devices can transmit data to a computer that can assist with daily life suggestions for lifestyleornutrition and with the physician can make suggestions for further study in people who are at risk and help prevent diabetes mellitus type 2 .[11]
Stress monitoring
Bio sensors may provide warnings when stress levels signs are rising before human can notice it and provide alerts and suggestions.[12] Deep neural network models using photoplethysmography imaging (PPGI) data from mobile cameras can assess stress levels with a high degree of accuracy (86%).[13]
Serotonin biosensor
Future serotonin biosensors may assist with mood disorders and depression.[14]
Continuous blood test based nutrition
In the field of evidence-based nutrition, a lab-on-a-chip implant that can run 24/7 blood tests may provide a continuous results and a computer can provide nutrition suggestions or alerts.
Psychiatrist-on-a-chip
In clinical brain sciences drug delivery and in vivo Bio-MEMS based biosensors may assist with preventing and early treatment of mental disorders
Epilepsy monitoring
Inepilepsy, next generations of long-term video-EEG monitoring may predict epileptic seizure and prevent them with changes of daily life activity like sleep, stress, nutrition and mood management.[15]
Toxicity monitoring
Smart biosensors may detect toxic materials such mercury and lead and provide alerts.[16]

Minimum standards of monitoring[edit]

Minimum acceptable monitoring

1. Clinical observation (one-to-one) 2. Pulse oximetry 3. Non-invasive blood pressure 4. ECG 5. Core temperature 6. End-tidal carbon dioxide (if tracheal tube or supraglottic airway device in situ)

Additional monitoring which should be immediately available

1. Blood/capillary glucose 2. Nerve stimulator

Additional monitoring which should be available

1. Urine output 2. Invasive pressure monitoring (arterial line, central venous pressure) 3. Cardiac output monitoring 4. Access to haematological and biochemical investigations

Essential Monitoring[edit]

Presence of the anaesthetist throughout anaesthesia

A. Induction and maintenance of anaesthesia

1. Pulse oximeter 2. Non-invasive blood pressure monitoring 3. Inspired and expired oxygen, carbon dioxide, nitrous oxide and vapour 4. Airway pressure 5. A nerve stimulator whenever a muscle relaxant is used 6. Temperature (pre-op) and for any procedure >30 min anaesthesia duration

B. Recovery from anaesthesia

1. Pulse oximeter 2. Non-invasive blood pressure monitor 3. Electrocardiograph 4. Capnograph if the patient has a tracheal tube or supraglottic airway device in situ, or is deeply sedated 5. Temperature

C. Additional monitoring

1. Some patients will require additional monitoring: e.g. intravascular pressures, cardiac output. 2. Depth of anaesthesia monitors recommended when patients are anaesthetised with total intravenous techniques.

D. Regional techniques & sedation for operative procedures

1. Pulse oximeter 2. Non-invasive blood pressure monitoring 3. Electrocardiograph 4. End-tidal carbon dioxide monitor if the patient is sedated.[17]

See also[edit]

References[edit]

  1. ^ Pachmann, Katharina; Camara, Oumar; Kohlhase, Annika; Rabenstein, Carola; Kroll, Torsten; Runnebaum, Ingo B.; Hoeffken, Klaus (2010-08-08). "Assessing the efficacy of targeted therapy using circulating epithelial tumor cells (CETC): the example of SERM therapy monitoring as a unique tool to individualize therapy". Journal of Cancer Research and Clinical Oncology. 137 (5): 821–828. doi:10.1007/s00432-010-0942-4. ISSN 0171-5216. PMC 3074080. PMID 20694797.
  • ^ a b c d e Fraser, C. G.; Fogarty, Y. (1989). "Interpreting laboratory results". BMJ (Clinical Research Ed.). 298 (6689): 1659–1660. doi:10.1136/bmj.298.6689.1659. PMC 1836738. PMID 2503170.
  • ^ C‐reactive protein (serum, plasma) from The Association for Clinical Biochemistry and Laboratory Medicine. Author: Brona Roberts. Copyrighted 2012
  • ^ Park SH, Kim SY, Lee W, Chun S, Min WK (2012). "New decision criteria for selecting delta check methods based on the ratio of the delta difference to the width of the reference range can be generally applicable for each clinical chemistry test item". Ann Lab Med. 32 (5): 345–54. doi:10.3343/alm.2012.32.5.345. PMC 3427822. PMID 22950070.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  • ^ a b Thomas Kampfrath (2017-08-01). "Delta Checks Checkup: Optimizing cutoffs with lab-specific inputs". American Association for Clinical Chemistry .
  • ^ "Healthcare 2030: disease-free life with home monitoring nanomedince". Positivefuturist.com.
  • ^ "Nanosensors for Medical Monitoring". Technologyreview.com. Archived from the original on 2012-01-31. Retrieved 2011-08-22.
  • ^ "Brain Damage Caused by Neuroleptic Psychiatric Drugs". Mindfreedom.org. 2007-09-15.
  • ^ "Medications That Can Cause Nerve Damage". Livestrong.com.
  • ^ a b Hyman, Mark (December 2008). The UltraMind Solution: Fix Your Broken Brain by Healing Your Body First. Scribner. ISBN 978-1-4165-4971-0.
  • ^ Genz, Jutta; Haastert, Burkhard; Meyer, Gabriele; Steckelberg, Anke; Müller, Hardy; Verheyen, Frank; Cole, Dennis; Rathmann, Wolfgang; Nowotny, Bettina; Roden, Michael; Giani, Guido; Mielck, Andreas; Ohmann, Christian; Icks, Andrea (2010). "Blood glucose testing and primary prevention of diabetes mellitus type 2 - evaluation of the effect of evidence based patient information". BMC Public Health. 10: 15. doi:10.1186/1471-2458-10-15. PMC 2819991. PMID 20074337.
  • ^ Jovanov, E.; Lords, A. O.; Raskovic, D.; Cox, P. G.; Adhami, R.; Andrasik, F. (2003). ""Stress monitoring using a distributed wireless intelligent sensor system"" (PDF). IEEE Engineering in Medicine and Biology Magazine. 22 (3). IEEE: 49–55. doi:10.1109/MEMB.2003.1213626. PMID 12845819. S2CID 902182. Archived from the original (PDF) on 2020-07-30.
  • ^ Al-Jebrni, Abdulrhman H.; Chwyl, Brendan; Wang, Xiao Yu; Wong, Alexander; Saab, Bechara J. (May 2020). "AI-enabled remote and objective quantification of stress at scale". Biomedical Signal Processing and Control. 59: 101929. doi:10.1016/j.bspc.2020.101929.
  • ^ HUANG YJ; MARUYAMA Y; Lu, K. S.; PEREIRA E; PLONSKY I; BAUR JE; Wu, D.; ROPER SD (2005). "Using Biosensors to Detect the Release of Serotonin from Taste Buds During Taste Stimulation". Archives Italiennes de Biologie. 143 (2): 87–96. PMC 3712826. PMID 16106989.
  • ^ Kamel JT, Christensen B, Odell MS, D'Souza WJ, Cook MJ (December 2010). "Evaluating the use of prolonged video-EEG monitoring to assess future seizure risk and fitness to drive". Epilepsy Behav. 19 (4): 608–11. doi:10.1016/j.yebeh.2010.09.026. PMID 21035403. S2CID 44834010.
  • ^ Karasinski, Jason; Sadik, Omowunmi; Andreescu, Silvana (2006). "Multiarray Biosensors for Toxicity Monitoring and Bacterial Pathogens". Smart Biosensor Technology. Optical Science and Engineering. Vol. 20065381. CRC. pp. 521–538. doi:10.1201/9781420019506.ch19. ISBN 978-0-8493-3759-8.
  • ^ Thompson, Jonathan P.; Moppett, Iain K.; Wiles, Matt, eds. (2019). Smith and Aitkenhead's textbook of anaesthesia (Seventh ed.). Edinburgh: Elsevier. ISBN 978-0-7020-7500-1. OCLC 1091648161.
  • Further reading[edit]

    External links[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Monitoring_(medicine)&oldid=1228139191"

    Categories: 
    Medical monitoring
    Nanomedicine
    Intensive care medicine
    Anesthesia
    Hidden categories: 
    CS1 maint: multiple names: authors list
    Articles with short description
    Short description matches Wikidata
    All articles with unsourced statements
    Articles with unsourced statements from February 2022
    Articles lacking reliable references from October 2011
    All articles lacking reliable references
    Commons category link is on Wikidata
    Articles with J9U identifiers
    Articles with LCCN identifiers
    Articles with LNB identifiers
     



    This page was last edited on 9 June 2024, at 17:27 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki