Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 History  





2 Dräger Medical GmbH  





3 Dräger Safety GmbH  



3.1  Colorimetric gas detector tubes  





3.2  Alcohol Screening Kits  







4 Diving equipment  



4.1  Atlantis/Dolphin  





4.2  Ray  



4.2.1  Construction  



4.2.1.1  Harness and assembly  





4.2.1.2  Breathing loop  





4.2.1.3  Gas supply  







4.2.2  Specifications  









5 High altitude breathing equipment  





6 See also  





7 References  





8 External links  














Dräger (company)






Deutsch
Español
فارسی
Français
Italiano
Magyar
Nederlands
Polski
Română
Русский
Svenska
Türkçe
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 




Print/export  







In other projects  



Wikimedia Commons
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


This is an old revision of this page, as edited by Monkbot (talk | contribs)at06:58, 4 January 2021 (Task 18 (cosmetic): eval 10 templates: hyphenate params (8×);). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.
(diff)  Previous revision | Latest revision (diff) | Newer revision  (diff)

Drägerwerk AG & Co. KGaA
Company typeKommanditgesellschaft auf Aktien with Aktiengesellschaftaspartner with unlimited liability

Traded as

FWBDRW3
IndustryEngineering, medical technology
Founded1889
FounderJ. Heinrich Dräger
Carl Adolf Gerling
HeadquartersLübeck, Germany

Key people

Stefan Dräger (CEO and chairman of the executive board), Nikolaus Schweickart (Chairman of the supervisory board)
ServicesDiving equipment, rebreathers, SCBA, medical ventilators and monitors, anaesthetic machines, neonatal incubators, gas detectors, breathalyzers, drug testing equipment
Revenue€2.78 billion (2019)[1]

Net income

€33.79 million (2019)[1]
Total assets€2.57 billion (2019)[1]
Total equity€1.08 billion (2019)[1]

Number of employees

14,845 (2019)[1]
Websitewww.draeger.com

Drägerwerk AG is a German company based in Lübeck[2] which makes breathing and protection equipment, gas detection and analysis systems, and noninvasive patient monitoring technologies.[3] Customers include hospitals, fire departments and diving companies.

History

The company was founded in Lübeck in 1889 as Dräger & GerlingbyJ. Heinrich Dräger [de] and Carl Adolf Gerling.[2] The first patent was taken out for a reduction device for using carbon dioxide to dispense beer. In 1902 Heinrich Dräger's son Bernhard entered the management; from then on, the company was named Drägerwerk Heinr. und Bernh. Dräger. Since 1970, Drägerwerk has been a public limited company, or Aktiengesellschaft (AG) in German.

In 2003, the aerospace division was sold to Cobham plc. In July 2006, it was announced that Draeger Aerospace GmbH had been acquired by B/E Aerospace, Inc.[4]

Draeger's stock tumbled to its lowest YTD close of 66.6 EU on 4/18/18. Its YTD high was 104.15 EU on 5/10/17. Stocks have been booming since the beginning of the COVID-19 pandemic.

Dräger Medical GmbH

Dräger Fabius Tiro
Draeger Evita v500 respirator. Arrow indicates Neoflow air flow sensor

Dräger Medical is a manufacturer of medical equipment. The company offers products and services including Emergency Care, Perioperative Care, Critical Care, Perinatal Care and Home Care. With headquarters in Lübeck, Germany, Dräger Medical employs nearly 14,000 people worldwide,[5] around half of whom work in customer sales & services. R&D and production are located in Lübeck, Germany; Best, Netherlands; Richmond Hill, ON, Canada; Telford, PA, USA; Andover, MA, USA; and Shanghai, China. The company has sales and service subsidiaries in almost 50 countries and is represented in more than 190 countries.[citation needed]

Dräger Safety GmbH

Dräger Safety GmbH is a manufacturer of personal protection and gas detection technology, and a supplier of safety systems for industry, fire prevention, mining and other hazardous areas.[6] The products and services from Dräger Safety warn and protect people from airborne pollutants and enable people to breathe reliably even in extreme situations.

Dräger claims to have longstanding experience, especially in the fields of gas management, gas flow control, gas monitoring and gas measurement. The current product range encompasses respiratory protective equipment for firefighters, miners and other industrial personnel as well as complete air filter and air supply systems, portable and fixed gas detection and warning systems, devices for on-site or laboratory contaminant analysis, and instruments to determine a person's breath-alcohol concentration.

Dräger combines the practical use of equipment with, for example, consultancy services, training, maintenance, service and commissioning. Represented in over 100 countries, the company has 40 subsidiaries and, with its 3,600 employees, achieved global sales of €557.8 million in 2005 (EBIT: €40.7 million).[citation needed] Dräger Safety operates production plants in Germany, Great Britain, USA, Sweden, South Africa and China.

Dräger Safety faces heavy competition from other manufacturers of safety equipment such as Sensidyne, LP. Also, the company's competitors include Mine Safety Appliances, Industrial Scientific Corporation and RAE Systems.[7]

Dräger supports the German Firefighting Sports Federation in the German firefighting fitness badge.[8]

Colorimetric gas detector tubes

Dräger was one of a few companies who were early pioneers of colorimetric gas detector tubes (also known as "detector tubes") used to measure the concentration of gases present. In a typical colorimetric gas detector tube a known volume of air is pumped through a tube using a pump. The tube typically has a layer which indicates the analyte by changing colour, depending on the amount of the gas which has passed through the tube the length of the zone which has changed colour will be different.[9][10] Today colorimetric gas detector tubes are used throughout industry as a low-cost and easy-to-use tool for detecting the presence of gases and are available from a wide range of manufacturers.

An early limitation of detector tubes is that they were designed to detect a single known gas or vapor. Advancements in the design and capability of detector tubes came with the introduction of such tools as the HazMat kit. The specialty kits are designed for use by hazardous material response teams in determining what gases or vapors are present through using a "stack" of colorimetric material that change color based upon the presence of an organic or inorganic gas.

Alcohol Screening Kits

Dräger developed their first Alcohol screening kit in 1953 when some employees came into work hungover following a party the night before. It was originally developed using silicon crystals, where a breath sample was passed through these silicon crystals, if there was alcohol in this breath sample, a chemical reaction would occur resulting in the crystals changing colour. This particular method is still used today to create "single use breathalyzers."

Dräger's first digital display Alcohol Screening Kit was developed in 1980. Later they developed a breathalyzer that uses a fuel sensor. Many of Drägers breathalyzers have home office approval, which means they can be used by the police in a variety of countries, including the UK.

Diving equipment

Dräger three-bolt bubikopf helmet in use for surface supplied diving
Helmeted diver entering the water. He has a back mounted Draeger DM40 rebreather system in addition to the surface supply air hose
Two cylinders hand pump (presented on picture without handles) made for divers in standard diving dress by Drägerwerk AG

In 1912 Drägerwerk developed standard diving dress which did not need surface supplied breathing gas via a diver's umbilical, as it used a self contained gas supply came from a rebreather. Two versions were available, one for oxygen to 20 metres, and the other for nitrox to 40 metres. The semi-closed circuit used the injected gas to circulate the gas in the helmet through a scrubber, providing a very low work of breathing in comparison with most other rebreathers which used the lungs of the diver to circulate gas in the loop. The bubikopf helmet was designed for use with this system. The rebreather loop hoses connected to the back of the helmet below the overhanging part, and led from there to the back-mounted scrubber.

Since 1941 Hans Hass used bag-on-back rebreathers for scuba diving, originally built by Dräger for self-rescue of submarine crews (Tauchretter; like the Davis Escape Set). The first Dräger-Tauchretter had been built in 1907. In 1926 the Bade-Tauchretter was brought into service for rescuing drowning swimmers.[11]

Dräger manufactured the popular Atlantis, Ray and Dolphin line of sport diving semi-closed-circuit nitrox rebreathers. It also makes the LAR-5 and LAR-6 military oxygen rebreathers, and the LAV-7 military rebreather which is switchable between closed-circuit and semi-closed-circuit.[12][13]

Atlantis/Dolphin

Partially assembled Dräger Dolphin

The Dräger Dolphin, originally Atlantis is a semi-closed circuit nitrox rebreather for recreational diving using a constant mass flow injection system.[14][15]

Ray

The Dräger Ray is a semi-closed circuit recreational diving rebreather designed to use standard nitrox breathing gas mixtures.

Construction

Harness and assembly

The soft harness has integrated over-the-shoulder counterlungs and buoyancy compensator bladder. The harness also carries a moderate sized scrubber canister on the upper back, and a single transversely mounted cylinder on the lower back. The Ray delivers a constant mass flow of gas to the breathing circuit through a Dräger Shark regulator and a metering orifice which is chosen from a small range, and which must be matched to the chosen gas mixture.

The whole unit excepting cylinders is supplied in a carrying case.

Breathing loop

The standard unit provides a simple dive/surface valve (DSV) with mouthpiece, but an optional DSV connects to the Dräger Panorama full-face mask using the standard Dräger P-port connection system which is also used for the connections between the breathing hoses and counterlungs, and between the counterlungs and scrubber canister. The back mounted scrubber has axial flow, and has an auxiliary P-port on the base, which can be used to connect an optional oxygen monitor cell.

The automatic diluent valve is combined with the metering orifice as a single unit which plugs into a counterlung using a standard P-port connection.

Gas supply

The standard cylinder supplied with the unit is a 4-litre 200 bar steel cylinder,[16] but it can also carry an 8-litre steel cylinder, which is about the same length but larger diameter. Standard open circuit bailout uses a Shark demand valve on the same first stage used for the metering and ADV. There is also a low pressure hose to supply the buoyancy compensator.

Specifications

Recreational semi-closed circuit rebreather with constant mass flow dosage and demand gas supply, open circuit bailout on independent second stage.[16][17]

High altitude breathing equipment

Dräger made the high-altitude oxygen sets used by the 1952 Swiss Mount Everest expedition (the second (autumn) expedition), and John Hunt was able to have adaptors made so that the 1953 British expedition could use oxygen from tanks the Swiss had left behind, particularly for their bottled oxygen "sleeping sets".[18]

See also

References

  1. ^ a b c d e "ANNUAL REPORT 2019" (PDF). Dräger. Retrieved 22 March 2020.
  • ^ a b ChemEurope. "Drägerwerk AG & Co. KGaA." Retrieved Feb 13, 2013.
  • ^ Bloomberg Businessweek. "Draegerwerk Ag - Pref (DRW3:Xetra)." Retrieved Feb 13, 2013.
  • ^ B/E Aerospace Announces the Acquisition of Draeger Aerospace GmbH
  • ^ Peter Cebon. "Measured Success." Retrieved Apr 18, 2013.
  • ^ http://www.process.vogel.de/Dr-C3-A4ger-Safety-AG-Co-KGaA/firma/197131
  • ^ Wikinvest. "Competition Archived 2014-08-08 at the Wayback Machine". Retrieved Apr 26, 2013.
  • ^ http://www.dfs-ev.de/index.php?page=dffa
  • ^ "Archived copy" (PDF). Archived from the original (PDF) on 2012-05-24. Retrieved 2012-06-30.{{cite web}}: CS1 maint: archived copy as title (link)
  • ^ "Dräger in Russia". Retrieved 2013-07-19.
  • ^ Quick, D. (1970). "A History Of Closed Circuit Oxygen Underwater Breathing Apparatus". Royal Australian Navy, School of Underwater Medicine. RANSUM-1-70. Retrieved 2009-03-20.
  • ^ Goble, Steve (2003). "Rebreathers". South Pacific Underwater Medicine Society Journal. 33 (2): 98–102. Archived from the original on 2009-08-08. Retrieved 2009-03-20.
  • ^ Images.
  • ^ Staff. "Scuba Diving Courses: PADI Semi-closed Re-breather Drager Dolphin / Atlantis Specialty Course". Hong Kong: dive-the-world.com. Retrieved 9 April 2018.
  • ^ Tom Byron (8 April 2014). History of Spearfishing and Scuba Diving in Australia: The First 80 Years 1917 to 1997. Xlibris Corporation. p. 296. ISBN 978-1-4931-3670-4.[self-published source]
  • ^ a b Kramer, Karl. "Draeger Ray". rebreather.de. Retrieved 18 October 2018.
  • ^ Bech, JamWillem. "Datasheet semiclosed rebreather Dräger Ray". www.therebreathersite.nl. Retrieved 18 October 2018.
  • ^ Hunt, John (1953). The Ascent of Everest. London: Hodder & Stoughton. pp. 51, 52, 130, 137, 173.
  • External links


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Dräger_(company)&oldid=998194467"

    Categories: 
    Companies based in Schleswig-Holstein
    Technology companies established in 1889
    Diving engineering
    Diving equipment manufacturers
    Gas sensors
    German brands
    Lübeck
    Manufacturing companies of Germany
    Rebreather makers
    1889 establishments in Germany
    Hidden categories: 
    Webarchive template wayback links
    CS1 maint: archived copy as title
    CS1: long volume value
    All articles with self-published sources
    Articles with self-published sources from December 2017
    Articles with short description
    Short description is different from Wikidata
    All articles with unsourced statements
    Articles with unsourced statements from February 2008
    Commons category link is on Wikidata
    Articles with ISNI identifiers
    Articles with VIAF identifiers
    Articles with GND identifiers
    Articles with LCCN identifiers
    Articles with NKC identifiers
    Articles with SUDOC identifiers
     



    This page was last edited on 4 January 2021, at 06:58 (UTC).

    This version of the page has been revised. Besides normal editing, the reason for revision may have been that this version contains factual inaccuracies, vandalism, or material not compatible with the Creative Commons Attribution-ShareAlike License.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki