Jump to content
 







Main menu
   


Navigation  



Main page
Contents
Current events
Random article
About Wikipedia
Contact us
Donate
 




Contribute  



Help
Learn to edit
Community portal
Recent changes
Upload file
 








Search  

































Create account

Log in
 









Create account
 Log in
 




Pages for logged out editors learn more  



Contributions
Talk
 



















Contents

   



(Top)
 


1 Theoretical basis  





2 Bibliography  



2.1  Primary Modeling Sources  





2.2  VPM Research and Development Sources  







3 VPM Dive Planning Software  





4 VPM Dive computers  





5 See also  





6 References  





7 External links  














Varying Permeability Model






Deutsch
Italiano
 

Edit links
 









Article
Talk
 

















Read
Edit
View history
 








Tools
   


Actions  



Read
Edit
View history
 




General  



What links here
Related changes
Upload file
Special pages
Permanent link
Page information
Cite this page
Get shortened URL
Download QR code
Wikidata item
 




Print/export  



Download as PDF
Printable version
 
















Appearance
   

 






From Wikipedia, the free encyclopedia
 


The Varying Permeability Model, Variable Permeability ModelorVPM is an algorithm that is used to calculate the decompression stops needed for ambient pressure dive profiles using specified breathing gases. It was developed by D.E. Yount and others for use in professional diving and recreational diving. It was developed to model laboratory observations of bubble formation and growth in both inanimate and in vivo systems exposed to pressure.[1] In 1986, this model was applied by researchers at the University of Hawaii to calculate diving decompression tables.[citation needed]

Theoretical basis[edit]

The VPM presumes that microscopic bubble nuclei always exist in water and tissues that contain water. Any nuclei larger than a specific "critical" size, which is related to the maximum dive depth (exposure pressure), will grow upon decompression when the diver ascends. The VPM aims to minimize the total volume of these growing bubbles by keeping the external pressure large, and the inspired inert gas partial pressures low during decompression. The model depends on the assumptions that different sizes of bubbles exist within the body; that the larger bubbles require less reduction in pressure to begin to grow than smaller ones; and that fewer large bubbles exist than smaller ones. These are used to construct an algorithm that provides decompression schedules designed to allow the larger, growing bubbles to be eliminated before they can cause problems.[2][3]

Bibliography[edit]

This bibliography list was compiled by E.B. Maiken and E.C. Baker as reference material for the V-Planner web site in 2002.[4]

Primary Modeling Sources[edit]

VPM Research and Development Sources[edit]

VPM Dive Planning Software[edit]

VPM Dive computers[edit]

See also[edit]

References[edit]

  1. ^ Yount, DE (1991). "Gelatin, bubbles, and the bends". In: Hans-Jurgen, K; Harper Jr, DE (Eds.) International Pacifica Scientific Diving... 1991. Proceedings of the American Academy of Underwater Sciences Eleventh Annual Scientific Diving Symposium held 25–30 September 1991. University of Hawaii, Honolulu, Hawaii. Archived from the original on January 13, 2013. Retrieved 2011-10-14.{{cite journal}}: CS1 maint: unfit URL (link)
  • ^ Bonuccelli, Corrado (10 March 2004). "Calculating deco schedule with VPM" (PDF). Retrieved 8 June 2016.
  • ^ Watts, Kevin (19 March 2007). "VPM For Dummies". Rebreather World. Retrieved 8 June 2016.
  • ^ a b "V-Planner dive decompression planning software". HHS Software. Retrieved 8 June 2016.
  • ^ "MultiDeco VPM & VPM-B & VPM-B/E & ZHL GF dive decompression software for technical divers".
  • ^ "Tech Diving Mag - Free online technical diving magazine - Ultimate Planner".
  • ^ "DecoPlanner". Archived from the original on 10 January 2006.
  • ^ "HLPlanner". Archived from the original on 2008-03-15. Retrieved 2008-04-16.
  • ^ "JDeco - Dive Decompression Software for JAVA Mobile Devices (Buhlmann and VPM-B)".
  • ^ "Yahoo! Groups - PalmVPM".
  • ^ Roach, Greg. "DivePlan - Decompression software for SymbianOS".
  • ^ Olsen, Eskil. "baltic deco planner - iPhone deco planning app".
  • ^ Willem Ferguson; et al. "13.2.2. Non-recreational open circuit dives, including decompression". Subsurface 4.5 User Manual. Retrieved 10 November 2016.
  • ^ "V-Planner Live VPM-B, VPM-B/E dive deco computer firmware".
  • ^ "MultiDeco-X1 VPM-B VPM-B/E ZHL-GF dive computer firmware".
  • ^ "MultiDeco-DR5/DRX VPM-B VPM-B/E ZHL-GF dive computer firmware".
  • ^ "Ratio Dive Computers".
  • ^ "Technical Dive Computers TDC-3".
  • External links[edit]


    Retrieved from "https://en.wikipedia.org/w/index.php?title=Varying_Permeability_Model&oldid=1181936975"

    Category: 
    Decompression algorithms
    Hidden categories: 
    CS1 maint: unfit URL
    Articles with short description
    Short description is different from Wikidata
    All articles with unsourced statements
    Articles with unsourced statements from June 2016
    Articles to be expanded from October 2021
    All articles to be expanded
    Articles using small message boxes
    All articles with dead external links
    Articles with dead external links from July 2018
    Articles with permanently dead external links
     



    This page was last edited on 26 October 2023, at 03:26 (UTC).

    Text is available under the Creative Commons Attribution-ShareAlike License 4.0; additional terms may apply. By using this site, you agree to the Terms of Use and Privacy Policy. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.



    Privacy policy

    About Wikipedia

    Disclaimers

    Contact Wikipedia

    Code of Conduct

    Developers

    Statistics

    Cookie statement

    Mobile view



    Wikimedia Foundation
    Powered by MediaWiki